1. Introduction
Thank you for choosing the Panasonic FY-GMP022-T Air Supply Grill. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new air supply grill. Please read these instructions thoroughly before use and retain them for future reference.
The FY-GMP022-T is designed to provide adjustable airflow as a blow grill within a ventilation system. It is suitable for ceiling installations and helps regulate air distribution in various indoor environments.
Figure 1: Panasonic FY-GMP022-T Air Supply Grill. This image shows the front view of the air supply grill, typically installed in a ceiling.
2. Safety Information
Please observe the following safety precautions to prevent injury or damage to the product.
- Installation Location: This air supply grill cannot be installed on floor surfaces. It is designed exclusively for ceiling mounting.
- Proximity to Detectors: Maintain a minimum distance of 4.9 feet (1.5 meters) between the air vent of this grill and any residential emergency alarm detector parts to ensure proper functioning of safety devices.
- Qualified Personnel: Installation and electrical connections should only be performed by qualified personnel in accordance with all local codes and regulations.
- Power Disconnection: Always disconnect power to the installation area before performing any installation, maintenance, or cleaning.
3. Package Contents
The package for the Panasonic FY-GMP022-T Air Supply Grill typically includes:
- One (1) Panasonic FY-GMP022-T Air Supply Grill unit.
- Installation hardware (may vary, refer to packaging).
- This instruction manual.
4. Specifications
| Model Number | FY-GMP022-T |
| Brand | Panasonic |
| Applicable Duct Diameter | φ2.0 inches (50 mm) |
| Embedded Dimensions | φ4.3 - 4.7 inches (110 - 120 mm) |
| Embedded Dimensions (with ring plate) | φ4.7 inches (120 mm) |
| Mountable Ceiling Material Thickness | 0.2 - 1.2 inches (6 - 30 mm) |
| Product Dimensions (L x W x H) | 5.91 x 5.91 x 4.61 inches |
| Item Weight | 14.1 ounces |
| Recommended Uses | Ventilating |
| Mounting Type | Ceiling Mount (Note: Not for floor installation) |
| Controller Type | Ring (for adjustment) |
| Number of Speeds | 3 |
5. Installation
This section outlines the general steps for installing the Panasonic FY-GMP022-T Air Supply Grill. Professional installation is recommended.
- Preparation: Ensure the power supply to the installation area is turned off at the circuit breaker. Verify that the ceiling material thickness is between 0.2 and 1.2 inches (6-30 mm).
- Cut Opening: Create a circular opening in the ceiling with a diameter suitable for the embedded dimensions, typically between φ4.3 - 4.7 inches (110 - 120 mm). If using a ring plate, the opening should accommodate φ4.7 inches (120 mm).
- Duct Connection: Connect the φ2.0 inches (50 mm) applicable duct to the grill's inlet. Ensure a secure and airtight connection.
- Insert Grill: Carefully insert the grill into the prepared ceiling opening. Ensure it sits flush with the ceiling surface.
- Secure Grill: Use the provided installation hardware (screws, clips, etc.) to securely fasten the grill to the ceiling structure.
- Final Check: Once installed, ensure the grill is stable and all connections are secure. Restore power to the area.
Important: Do not install this unit on floor surfaces. Maintain the specified distance from emergency alarm detectors.
6. Operation
The Panasonic FY-GMP022-T Air Supply Grill is designed for straightforward operation as a blow grill with adjustable airflow.
- Airflow Adjustment: The grill features a ring-type controller for adjusting the airflow. Rotate the ring to select one of the 3 available speeds or airflow settings.
- Function: This unit functions as a blow grill, directing conditioned air into the room.
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your air supply grill.
- Cleaning: Periodically wipe the exterior surface of the grill with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish.
- Dust Removal: If dust accumulates within the grill's vanes, gently clean with a soft brush or vacuum cleaner attachment.
- Inspection: Annually inspect the grill for any signs of damage, loose connections, or obstructions.
- Power Off: Always turn off the power supply before performing any cleaning or maintenance.
8. Troubleshooting
If you encounter issues with your Panasonic FY-GMP022-T Air Supply Grill, refer to the following common troubleshooting steps.
- Reduced Airflow:
- Check for obstructions in the ductwork or within the grill itself.
- Ensure the airflow adjustment ring is set to the desired speed/setting.
- Verify that the main ventilation system is operating correctly.
- Unusual Noise:
- Ensure the grill is securely mounted and not vibrating against the ceiling.
- Check for any loose components or debris inside the grill.
- Grill Not Functioning:
- This grill is a passive component for air distribution. If no air is flowing, check the main ventilation fan or HVAC system.
If problems persist after attempting these steps, please contact Panasonic customer support.
9. Warranty and Support
For warranty information, technical support, or service inquiries regarding your Panasonic FY-GMP022-T Air Supply Grill, please refer to the official Panasonic website or contact their customer service department.
You can find more information and support resources by visiting the official Panasonic store or support pages:
Visit the Panasonic Store on Amazon