1. Introduction

This manual provides essential information for the safe and effective use of the BAQICK 902818 Replacement Electric Furnace Heating Element. This component is designed as a direct replacement for specific Nordyne, Intertherm, and Miller electric furnace models. Please read this manual thoroughly before installation or operation to ensure proper function and safety.

2. Safety Information

WARNING: Electric furnaces operate with high voltage and high temperatures. Improper installation or handling can result in electric shock, fire, property damage, or serious injury. Always prioritize safety.

3. Product Overview

The BAQICK 902818 is a 5kW replacement heating element designed for various Nordyne, Intertherm, and Miller electric furnace models. It is manufactured to meet the specifications of the original equipment, ensuring reliable performance.

BAQICK 902818 Replacement Electric Furnace Heating Element

Image 1: BAQICK 902818 Replacement Electric Furnace Heating Element. This image displays the coiled heating wires mounted on a rectangular metal plate, with visible connection points on the left and right sides.

Compatible Furnace Models:

This heating element is compatible with several Nordyne, Intertherm, and Miller Electric Furnace models, including but not limited to:

Replaces Part Numbers:

This part replaces the following original equipment manufacturer (OEM) part numbers:

4. Setup and Installation

Installation of a furnace heating element requires specific technical knowledge and adherence to safety protocols. It is strongly recommended that this procedure be carried out by a certified HVAC professional or a qualified electrician.

General Installation Steps (For Qualified Personnel Only):

  1. Power Disconnection: Turn off all power to the furnace at the main electrical panel. Confirm power is off using a voltage meter.
  2. Access Furnace Compartment: Open the furnace access panel to locate the heating element assembly.
  3. Document Wiring: Take clear photos or make a diagram of the existing wiring connections to the old heating element.
  4. Remove Old Element: Carefully disconnect the wiring and mounting hardware securing the old heating element. Remove the old element.
  5. Install New Element: Position the BAQICK 902818 replacement element in the furnace, ensuring it fits correctly. Secure it with the appropriate mounting hardware.
  6. Connect Wiring: Reconnect the electrical wiring to the new element according to your documentation. Ensure all connections are tight and secure.
  7. Close Compartment: Replace the furnace access panel.
  8. Restore Power and Test: Restore power to the furnace at the main electrical panel. Test the furnace operation to ensure the new heating element functions correctly. Monitor for any unusual sounds or smells during initial operation.

5. Operating Instructions

Once the BAQICK 902818 heating element is correctly installed by a qualified professional, its operation is integrated into the overall function of your electric furnace. The element will activate automatically when the thermostat calls for heat, providing warmth to your space.

6. Maintenance

The BAQICK 902818 heating element itself typically requires minimal direct maintenance. However, regular maintenance of the entire furnace system is crucial for its longevity and efficient operation.

7. Troubleshooting

If your furnace is not heating properly after the installation of the new element, consider the following common issues. For complex problems, always consult a qualified HVAC technician.

ProblemPossible CauseSolution
Furnace not producing heatNo power to furnace; tripped circuit breaker; faulty thermostat; incorrect wiring; other furnace component failure.Check circuit breaker and reset if tripped. Verify thermostat settings. Re-check wiring connections (if qualified). Consult a technician for further diagnosis.
Weak or insufficient heatClogged air filter; restricted airflow; incorrect element installation; other furnace component issues.Replace or clean air filter. Ensure vents are unobstructed. Verify element installation (if qualified). Consult a technician.
Element fails shortly after installationImproper installation; voltage incompatibility; underlying furnace issue; manufacturing defect.Contact the installer to review the installation. Verify furnace voltage. Contact the seller for potential warranty claims if a defect is suspected.

8. Specifications

9. Warranty Information

Specific warranty details for the BAQICK 902818 Replacement Electric Furnace Heating Element may vary. Please refer to the product packaging or contact the seller directly for information regarding warranty coverage, terms, and conditions. Keep your proof of purchase for any warranty claims.

10. Customer Support

For technical assistance, compatibility questions, or support regarding the BAQICK 902818 heating element, please contact the seller or manufacturer. When contacting support, have your furnace model number and the part number (902818) readily available.

For issues related to your furnace's overall operation, it is recommended to contact a certified HVAC technician.

Related Documents - 902818

Preview Partners Choice E7 Series Electric Furnace Replacement Parts List
Comprehensive replacement parts list for Partners Choice E7 Series electric furnaces, including model numbers and part numbers for components like blower housing, motors, circuit breakers, and doors. Nortek Global HVAC LLC.