LeuchtenDirekt 50376-17
User Manual
LeuchtenDirekt Piazzi Ceiling Light
Model: 50376-17
1. Introduction
Thank you for choosing the LeuchtenDirekt Piazzi Ceiling Light, model 50376-17. This modern ceiling fixture is designed to provide versatile illumination with its included G4 LED bulbs and additional white and violet LEDs, controllable via an infrared remote. This manual provides essential information for safe installation, operation, and maintenance of your new light fixture.
Figure 1: Front view of the LeuchtenDirekt Piazzi Ceiling Light. This image shows the square, chrome-finished fixture with four main G4 light sources and surrounding decorative crystals, along with integrated white and violet LEDs.
2. Safety Instructions
Please read all safety instructions carefully before installation and use. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Professional Installation Recommended: Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.
- Disconnect Power: Always disconnect the main power supply at the circuit breaker or fuse box before installing, cleaning, or servicing the fixture.
- Voltage Compatibility: Ensure the power supply voltage is compatible with the fixture's requirements.
- Secure Mounting: Ensure the mounting surface is strong enough to support the weight of the fixture.
- Handle with Care: The fixture contains glass and delicate components. Handle with care to prevent breakage.
- Bulb Type: Use only G4 type bulbs as specified. Do not exceed the maximum wattage of 14 Watts per bulb.
- Cleaning: Clean only with a dry, soft cloth. Do not use abrasive cleaners or solvents.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation.
- 1 x LeuchtenDirekt Piazzi Ceiling Light Fixture (Model: 50376-17)
- 4 x G4 LED Bulbs (14 Watts each)
- 1 x Infrared Remote Control (requires 2 x AAA batteries, included)
- Mounting Hardware (screws, anchors)
- Instruction Manual
4. Setup and Installation
Follow these steps for proper installation. If you are unsure about any step, consult a qualified electrician.
- Prepare for Installation:
- Turn off the main power supply to the installation area at the circuit breaker or fuse box.
- Ensure the power is off by testing the circuit with a voltage tester.
- Unpack the fixture and all components carefully.
- Mount the Fixture Base:
- Determine the desired mounting location on the ceiling.
- Mark the drilling points for the mounting bracket using the fixture's base as a template.
- Drill pilot holes and insert appropriate wall anchors if necessary.
- Secure the mounting bracket to the ceiling using the provided screws.
- Wire the Fixture:
- Connect the household electrical wires to the fixture's wires according to standard wiring codes (e.g., black to black, white to white, ground to ground). Use wire nuts to secure connections.
- Carefully tuck all wires into the junction box.
- Attach the Fixture Body:
- Align the fixture body with the mounting bracket and secure it with the provided screws or fasteners.
- Ensure the fixture is firmly attached and flush with the ceiling.
- Install G4 Bulbs:
- Gently insert the pins of the G4 LED bulbs into their respective sockets. Do not force them.
- Ensure all bulbs are seated correctly.
- Restore Power:
- Once installation is complete, restore power at the circuit breaker.
- Test the light fixture using the wall switch and the remote control.
Figure 2: Angled view of the LeuchtenDirekt Piazzi Ceiling Light, showing its square design and the arrangement of the four main light sources and surrounding crystal elements.
5. Operating Instructions
The LeuchtenDirekt Piazzi Ceiling Light can be operated via a standard wall switch and the included infrared remote control.
5.1. Wall Switch Operation
A standard wall switch will turn the entire fixture (all lights) ON or OFF.
5.2. Remote Control Functions
The infrared remote control allows for advanced control over the light's features, including separate switching of light sources and color modes.
- Power ON/OFF: Standard button to turn the fixture on or off.
- Separate Switching: The remote allows you to switch the G4 LED bulbs and the integrated white/violet LEDs independently. Refer to the remote's button layout for specific controls.
- White LED Mode: Activates the integrated white LEDs for general illumination.
- Violet LED Mode: Activates the integrated violet LEDs for ambient or decorative lighting.
- Combined Mode: Activates both G4 bulbs and integrated LEDs.
- Dimming: The fixture is dimmable. Use the designated dimming buttons on the remote to adjust brightness levels.
Figure 3: The ceiling light illuminated with its white LED mode, providing bright, clear light.
Figure 4: The ceiling light illuminated with its violet LED mode, creating an ambient, colored lighting effect.
Figure 5: The ceiling light illuminated with a combination of white and violet LEDs, showcasing its versatile lighting options.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your ceiling light.
6.1. Cleaning
- Disconnect Power: Always turn off the power supply to the fixture before cleaning.
- Fixture Body: Wipe the chrome finish and glass components with a soft, dry, lint-free cloth.
- Avoid Chemicals: Do not use abrasive cleaners, solvents, or harsh chemicals, as they can damage the finish or electrical components.
6.2. Bulb Replacement
The G4 LED bulbs are replaceable. Ensure you use the correct type and wattage.
- Disconnect Power: Turn off the power supply to the fixture at the circuit breaker.
- Allow to Cool: If the light has been on, allow the bulbs to cool down completely before handling.
- Remove Old Bulb: Gently pull the old G4 bulb straight out from its socket.
- Install New Bulb: Carefully insert the pins of the new G4 LED bulb into the socket. Do not twist or force.
- Restore Power: Once all bulbs are replaced, restore power and test the fixture.
6.3. Recycling Information
For information on recycling your old light bulbs and the fixture itself, please consult local recycling guidelines or visit relevant recycling resources.
For more information on recycling, you can refer to general guidelines on how to recycle light bulbs and how to clean light bulbs (referring to general Amazon help pages as specific product info is not available).
7. Troubleshooting
If you encounter issues with your LeuchtenDirekt Piazzi Ceiling Light, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on. |
|
|
| Light flickers or dims unexpectedly. |
|
|
| Remote control not working. |
|
|
8. Specifications
Technical details for the LeuchtenDirekt Piazzi Ceiling Light (Model: 50376-17).
| Brand: | LeuchtenDirekt |
| Manufacturer: | LeuchtenDirekt |
| Model Number: | 50376-17 |
| Product Dimensions (L x W x H): | 40 x 40 x 8 cm |
| Item Weight: | 8 Kilograms |
| Style: | Modern |
| Number of Bulbs: | 4 (G4 LED) + additional integrated LEDs |
| Maximum Wattage: | 14 Watts per G4 bulb |
| Bulb Type: | Halogen (G4 base, but includes LED G4 bulbs) |
| Base Type: | G4 |
| Energy Efficiency Label: | C |
| Luminous Flux: | 155 lm |
| Incandescent Equivalence: | 19 Watts |
| Features: | Dimmable, Infrared Remote Control, Separately Switchable White and Violet LEDs |
| Color Rendering Index (CRI): | 98 |
| Average Lifespan: | 2000 Hours |
| Batteries Required: | Yes (2 x AAA for remote, included) |
| First Available on Amazon.fr: | 19 November 2013 |
Figure 6: Energy efficiency label indicating the fixture's rating and compatibility with various LED lamp energy classes.
9. Warranty and Support
Specific warranty details are not provided in the product information. For warranty claims, technical support, or spare parts inquiries, please contact LeuchtenDirekt customer service directly or the retailer from whom you purchased the product.
Please retain your proof of purchase for any warranty-related issues.