NaceCare GVE 370 George

NaceCare GVE 370 "George" Wet/Dry/ Extractor Vacuum Instruction Manual

Model: GVE 370 George | Brand: NaceCare

1. Product Overview

The NaceCare GVE 370 "George" is a versatile all-in-one machine designed for both wet and dry cleaning applications. It excels at dry vacuuming, wet vacuuming, scrubbing and drying hard floors, deep cleaning carpets, cleaning upholstery, and even unblocking sinks. Its robust design ensures professional cleaning standards and exceptional results for extensive and long-hour use.

NaceCare GVE 370 George Vacuum Cleaner

Figure 1: NaceCare GVE 370 "George" Wet/Dry/ Extractor Vacuum.

This image displays the main unit of the NaceCare GVE 370 "George" vacuum cleaner, showcasing its green body, black top, and the attached hose with a clear extraction nozzle.

2. Package Contents

Before beginning, ensure all components are present in the packaging:

  • NaceCare GVE 370 "George" main unit
  • 26A Accessory Kit (includes various nozzles and tools)
  • Hoses for wet and dry operation
  • Power cord
  • Instruction Manual (this document)
NaceCare GVE 370 George Vacuum Accessories

Figure 2: Included 26A Accessory Kit components.

This image shows the comprehensive 26A accessory kit, including various hoses, extension wands, floor tools, and specialized nozzles for different cleaning tasks.

3. Setup

3.1 Initial Assembly

  1. Unpack all components from the box.
  2. Ensure the main unit is placed on a stable, level surface.
  3. Attach the appropriate hose for your intended use (dry or wet).
  4. Connect the desired accessory (e.g., floor tool, upholstery nozzle) to the end of the hose.
  5. Plug the power cord into a suitable electrical outlet.

3.2 Preparing for Wet Operation (Extraction/Wet Vacuuming)

  • Remove the motor head from the main unit.
  • Fill the clean water tank with water and appropriate cleaning solution (refer to solution manufacturer's instructions).
  • Ensure the dirty water tank is empty and properly seated.
  • Replace the motor head, ensuring it is securely latched.
  • Connect the solution hose from the machine to the spray trigger on the wand.

3.3 Preparing for Dry Operation

  • Remove the motor head from the main unit.
  • Ensure the dry filter is clean and properly installed.
  • Insert a new dust bag if needed.
  • Replace the motor head, ensuring it is securely latched.

4. Operating Instructions

4.1 Dry Vacuuming

For general dry vacuuming of carpets and hard floors:

  1. Ensure the machine is set up for dry operation (dry filter and dust bag installed).
  2. Select the appropriate dry floor tool.
  3. Turn on the vacuum motor using the power switch.
  4. Move the floor tool slowly and steadily over the surface to be cleaned.

4.2 Wet Vacuuming (Spill Pickup)

For picking up liquid spills:

  1. Ensure the machine is set up for wet operation (no dry filter or dust bag, dirty water tank ready).
  2. Attach the wet pick-up tool.
  3. Turn on the vacuum motor.
  4. Move the wet pick-up tool over the liquid spill to suction it into the dirty water tank.

4.3 Carpet and Upholstery Extraction

For deep cleaning carpets and upholstery:

  1. Ensure the machine is set up for wet operation with the clean water tank filled with solution.
  2. Attach the carpet or upholstery extraction tool.
  3. Turn on both the vacuum motor and the pump switch.
  4. Press the spray trigger on the wand to dispense cleaning solution while simultaneously moving the tool over the surface to extract the dirty solution.
  5. Work in small sections, overlapping passes to ensure thorough cleaning and extraction.

Video 1: Vacuuming with Numatic Henry Wash (demonstrates similar wet cleaning functionality).

This video demonstrates the wet vacuuming and extraction process using a similar Numatic Henry Wash model. It shows the setup of the machine for wet use, including filling the solution tank and attaching the appropriate tools. The video then illustrates the technique for spraying cleaning solution and simultaneously vacuuming it up to clean surfaces.

4.4 Hard Floor Cleaning

George takes water and detergent from the clean water tank, breaks down grease and grime, and cleans the floor with his unique dual scrub brush. He then sucks-up the water into the dirty water tank, leaving your floors clean, hygienic, and touch dry.

NaceCare GVE 370 George Hard Floor Cleaning

Figure 3: Hard floor cleaning in progress.

This image shows the George vacuum's floor tool actively cleaning a dirty tiled floor, with a clear distinction between the cleaned and uncleaned areas, highlighting its effectiveness.

NaceCare GVE 370 George Hard Floor Cleaning with Foam

Figure 4: Example of hard floor cleaning with foam.

This image illustrates the hard floor cleaning process, showing the floor tool moving across a dark tiled surface with cleaning foam, indicating the scrubbing action.

5. Maintenance

5.1 Emptying and Cleaning Tanks

  • After wet use, always empty and rinse both the clean and dirty water tanks thoroughly.
  • Allow tanks to air dry before storage to prevent mold and odors.

5.2 Filter Maintenance

  • For dry use, regularly check and clean the disk filter. Tap off loose debris or rinse if washable (refer to specific filter instructions).
  • Replace the dry filter when it shows signs of wear or reduced performance.

5.3 Hose and Accessory Care

  • Rinse hoses and accessories after wet use to remove any residue.
  • Store hoses neatly to prevent kinks or damage.
  • Inspect all attachments for blockages or damage before and after each use.

6. Troubleshooting

  • No Suction:
    • Check if the hose is securely connected to the machine and the tool.
    • Ensure the tanks are properly sealed and the motor head is latched.
    • Verify that the filter is not clogged.
    • Check for blockages in the hose or tools.
  • Sprayer Not Working:
    • Ensure the clean water tank has sufficient solution.
    • Check if the pump switch is turned on.
    • Inspect the solution hose for kinks or blockages.
    • Clean the spray nozzle if it appears clogged.
  • Machine Not Turning On:
    • Verify the power cord is securely plugged into a working outlet.
    • Check the power switch on the machine.
    • Ensure the motor head is correctly seated and latched.

7. Specifications

FeatureDetail
BrandNaceCare
Model NameGVE 370 George
Special FeatureWet cleanup, corded
Filter TypeDisk
Capacity4 Gallons
Wattage1060 watts
Motor Horsepower1.6 HP
Product Dimensions14"L x 14"W x 20"H
Item Weight18 pounds
Noise Level61 dB
UPC799632475668

8. Warranty and Support

The NaceCare GVE 370 "George" comes with a 2-year warranty on switches, motors, and electrical parts. For warranty claims or technical support, please contact NaceCare Solutions directly or visit their official website.

For additional information and support, you may visit the NaceCare Store on Amazon.

© 2025 NaceCare Solutions. All rights reserved.