Ranco A30-2210

Ranco A30-2210 Temperature Control Instruction Manual

Model: A30-2210

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your Ranco A30-2210 Temperature Control. This device is designed as a refrigeration control with a constant differential, suitable for various applications requiring precise temperature regulation. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

2. Safety Information

WARNING: Electrical shock hazard. Disconnect power before installing or servicing this control. Failure to do so may result in serious injury or death.

3. Product Features

4. Specifications

SpecificationValue
Model NumberA30-2210
Control TypeRefrigeration, Constant Differential
Switch TypeSPST (Single Pole Single Throw)
Switch ActionClose on Rise
Control Range32°F to 61°F
Constant Differential8°F
Capillary Length48 inches
Voltage120/240V AC
Full Load Amps20A
Locked Rotor Amps80/80A
Warm On42°F
Warm Off30°F
Normally On40°F
Normally Off32°F
Cold Off30°F
Item Weight5.3 ounces
Product Dimensions5 x 5 x 5 inches

5. Installation (Setup)

The Ranco A30-2210 Temperature Control is designed for straightforward installation, including a dial knob and mounting bracket.

  1. Power Disconnection: Ensure all power to the refrigeration system is disconnected at the main circuit breaker before beginning installation.
  2. Mounting: Use the provided mounting bracket to secure the control unit in a suitable location. The location should be easily accessible for adjustment and away from direct heat sources or excessive vibration.
  3. Capillary Tube Placement: Carefully route the 48-inch capillary tube to the area where temperature sensing is required. The end of the capillary tube (bulb) must be positioned to accurately reflect the temperature of the controlled space. Avoid kinking or sharply bending the tube.
  4. Wiring: Connect the electrical wiring according to the wiring diagram provided with your refrigeration system and the specifications of the A30-2210 control (120/240V, SPST, Close on Rise). Ensure all connections are secure and insulated.
  5. Final Check: Double-check all connections and mounting before restoring power.
Ranco A30-2210 Temperature Control with dial knob and coiled capillary tube
This image displays the Ranco A30-2210 Temperature Control unit. It features a black control panel with a central dial knob for temperature adjustment, marked with numbers 1 through 7 and arrows indicating 'Colder'. Two mounting screws are visible on the panel. Extending from the top of the unit is a coiled copper capillary tube, which is essential for sensing temperature.

6. Operation

Once installed and powered, the Ranco A30-2210 Temperature Control operates by sensing the temperature via its capillary tube and activating/deactivating the refrigeration system based on the set point.

7. Maintenance

Regular maintenance helps ensure the longevity and accurate performance of your Ranco A30-2210 Temperature Control.

8. Troubleshooting

Refer to the following common issues and solutions before contacting technical support.

ProblemPossible CauseSolution
System not cooling or heating (depending on application)No power to the control; Incorrect wiring; Faulty control; Capillary tube damaged or improperly placed.Check power supply and circuit breaker. Verify wiring against diagram. Inspect capillary tube for damage and correct placement. If all else fails, the control may be faulty and require replacement.
System runs continuously or cycles too frequentlySet point too low/high; Capillary tube not sensing temperature correctly; System refrigerant issues (external to control).Adjust the set point. Ensure the capillary tube is properly located and undamaged. Consult a refrigeration technician for system-related issues.
Temperature fluctuates widely or is inaccurateCapillary tube improperly placed or damaged; Control differential not suitable for application; External drafts or heat sources affecting sensor.Relocate or inspect the capillary tube. Ensure the control's 8°F differential is acceptable for your needs. Shield the sensor from external influences.

9. Warranty and Support

For warranty information, please refer to the documentation provided by Ranco or your product supplier at the time of purchase. Typically, Ranco products carry a manufacturer's warranty against defects in materials and workmanship for a specified period, often one year from the date of installation. Specific terms and conditions may vary.

For technical support or service inquiries, please contact your authorized Ranco distributor or the Ranco customer service department.

Related Documents - A30-2210

Preview Ranco, Johnson Controls, and Danfoss Refrigeration Controls Catalog
Comprehensive catalog of Ranco, Johnson Controls, and Danfoss temperature and pressure controls, including low pressure limit controls, high-low pressure controls, electronic controls, defrost controls, and accessories for refrigeration systems.
Preview Ranco Single Pressure Control Installation Data
Installation data for Ranco single pressure controls (010, 011, 016, 020). Covers description, application, installation, wiring, and control settings for various refrigerants and pressure ranges.
Preview Ranco ETC Two Stage Electronic Temperature Control - NEMA Type 4X Installation Data
Installation data, specifications, operation, and troubleshooting for the Ranco ETC Two Stage Electronic Temperature Control, NEMA Type 4X. This control is designed for commercial HVAC and refrigeration, offering dual-stage temperature control, LCD display, keypad programming, and a NEMA 4X watertight enclosure for outdoor use.
Preview Ranco ETC Single Stage Electronic Temperature Control Installation Instructions
Comprehensive installation, operation, and troubleshooting guide for the Ranco ETC Single Stage Electronic Temperature Control. Covers product details, applications, features, specifications, ordering, programming, lockout switch, wiring diagrams, and sensor information for HVAC and refrigeration systems.
Preview Ranco O10/O11/O16/O20 Single Pressure Control Installation Data
Comprehensive installation data, wiring, settings, and specifications for Ranco O10, O11, O16, and O20 single pressure controls used in commercial refrigeration and air conditioning systems. Includes mounting instructions, capillary care, control wiring, adjustment procedures, and detailed specifications.
Preview Ranco Bottom Dump Trailer Operation, Maintenance & Parts Manual
Comprehensive guide for Ranco Bottom Dump Trailers covering operation, maintenance, parts, electrical, air brake, and suspension systems. Essential for proper use and upkeep.