1. Important Safety Information
Please read these instructions carefully before using the Legrand OmniRex Mechanical Weekly Timer. Failure to follow these instructions may result in electric shock, fire, or personal injury.
- Electrical Safety: This device operates on 230 V, 50 Hz. Ensure the power outlet matches these specifications. Do not exceed the maximum switching capacity of 16 A~ (3680 W).
- Child Safety: The timer is equipped with integrated child protection. However, always supervise children around electrical devices.
- Environment: Do not expose the timer to water, excessive moisture, or extreme temperatures. Use indoors only.
- Maintenance: Do not attempt to open or repair the device. Refer all servicing to qualified personnel.
- Disposal: Dispose of the product according to local regulations for electronic waste.
2. Product Overview
The Legrand OmniRex Mechanical Weekly Timer (Model 699812) is an analogue timer designed for automatic control of electrical appliances over a 7-day period. It features a robust mechanical design and integrated child safety.

Figure 2.1: Angled view of the Legrand OmniRex Mechanical Weekly Timer, showing the plug, socket, and the weekly programming dial.
2.1 Components
- Weekly Programming Dial: The large rotating dial with segments for each day and hour.
- Manual Override Switch: A slider switch on the side to manually turn the connected appliance ON, OFF, or set to Timer mode.
- Socket Outlet: The receptacle for plugging in the appliance to be controlled.
- Plug: For connecting the timer to a wall outlet.

Figure 2.2: Side view highlighting the manual override switch, which allows selection between timer control, always ON, or always OFF.
3. Setup Instructions
- Unpack the Timer: Carefully remove the timer from its packaging.
- Plug into Power Outlet: Insert the timer's plug into a standard 230 V, 50 Hz wall socket.
- Set Current Time and Day:
- Rotate the large weekly programming dial clockwise until the current day (Mo, Tu, We, Th, Fr, Sa, Su) aligns with the small arrow indicator on the timer's body.
- Continue rotating until the current hour aligns with the arrow. The dial is marked with 24 hours (1-24) and days of the week.
- Connect Appliance: Plug the appliance you wish to control into the socket outlet of the timer. Ensure the appliance is switched ON if it has its own power switch.

Figure 3.1: Front view of the timer, illustrating the weekly programming dial with day and hour markings for setting the current time and programming.
4. Operating Instructions
4.1 Programming the Weekly Timer
The timer allows you to set ON/OFF periods for each day of the week. The shortest switching time is 2 hours, with a switching precision of +/- 30 minutes.
- Identify Segments: The programming dial has segments around its circumference. Each segment represents a specific time interval.
- Set ON Periods: To set an appliance to turn ON, push the corresponding segments outwards. These pushed-out segments represent the time when the appliance will be powered.
- Set OFF Periods: To set an appliance to turn OFF, leave the corresponding segments in their inward position. These inward segments represent the time when the appliance will not be powered.
- Review Program: Once all desired ON/OFF periods are set for the week, ensure the manual override switch is in the timer position (often indicated by a clock symbol or "I").
4.2 Manual Override Switch
The manual override switch on the side of the timer allows you to temporarily bypass the programmed settings:
- Timer Mode (Clock Symbol / "I"): The timer operates according to the programmed ON/OFF settings.
- Always ON Mode ("O"): The connected appliance will remain continuously powered, regardless of the programmed settings.
- Always OFF Mode ("II"): The connected appliance will remain continuously unpowered, regardless of the programmed settings.
5. Maintenance
The Legrand OmniRex Mechanical Weekly Timer requires minimal maintenance.
- Cleaning: Disconnect the timer from the power outlet before cleaning. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Storage: If storing the timer for an extended period, keep it in a dry, dust-free environment.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Appliance does not turn ON/OFF as programmed. |
|
|
| Timer dial is not rotating. |
|
|
| Timer is inaccurate (time drift). |
|
|
7. Specifications

Figure 7.1: Rear view of the timer, showing the product label with model number, electrical ratings, and certifications.
| Feature | Detail |
|---|---|
| Model Number | 699812 |
| Type | Analogue Mechanical Weekly Timer |
| Rated Voltage | 230 V, 50 Hz |
| Switching Capacity | 16 A~ (max. 3680 W) |
| Program Type | 7-day (Weekly) |
| Shortest Switching Time | 2 hours |
| Switching Accuracy | +/- 30 minutes |
| Protection Class | IP20 |
| Dimensions (L x W x H) | 7.5 x 5.8 x 14 cm |
| Weight | 112 g |
| Material | Plastic |
| Certifications | GS tested, conforms to VDE 0631 part 1 and part 2-7, EN 60730-1 and EN 60730-2-7 |
8. Warranty and Support
Legrand products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the documentation provided with your purchase or visit the official Legrand website.
For technical support or inquiries, please contact Legrand customer service through their official channels. When contacting support, please have your product model number (699812) and purchase details available.
You can find more information and contact details on the official Legrand website: www.legrand.com