Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your Galcon 9001D Hose End Tap Timer. Please read this manual thoroughly before using the device to ensure proper function and longevity. The Galcon 9001D is designed to automate watering for lawns, gardens, and potted plants, offering programmable control directly from your hose tap.
Safety Information
- Use only one 9-volt alkaline battery (not included). Do not mix old and new batteries, or different types of batteries.
- Ensure the battery compartment is sealed properly to prevent water ingress.
- Operating pressure range is 15-145 PSI (1-10 Bars). Do not exceed these limits.
- Remove the timer and battery during winter months to prevent freezing damage.
- Keep the device away from extreme temperatures and direct sunlight for prolonged periods to maintain optimal performance.
Package Contents
Verify that all items are present in the package:
- Galcon 9001D Hose End Tap Timer
- User Manual (this document)
Product Overview
The Galcon 9001D is a programmable hose end timer designed for automated irrigation. It features a clear LCD display and intuitive buttons for easy programming.

Image: The Galcon 9001D Hose End Tap Timer, showing its LCD screen, control buttons, and hose connections.
Key Features
- 3/4" FHT inlet and MHT outlet for standard hose connections.
- Large integrated liquid crystal display for clear visibility.
- Six control buttons for easy programming.
- Programmable watering duration from 1 minute to 12 hours, in 1-minute increments.
- Supports weekly or daily programming with up to four start times per day.
- Manual operation and rain-off suspension options.
- Weather and UV resistant construction.
- Low battery indicator light.
Setup
1. Battery Installation
- Locate the battery compartment on the back of the timer.
- Open the compartment cover.
- Insert one new 9-volt alkaline battery, ensuring correct polarity.
- Securely close the battery compartment cover to ensure a watertight seal.
2. Connecting the Timer
- Attach the timer's inlet (top connection) to your outdoor hose bib (faucet). Hand-tighten firmly to prevent leaks.
- Connect your garden hose or drip irrigation line to the timer's outlet (bottom connection). Hand-tighten firmly.

Image: The Galcon 9001D timer properly installed between a hose bib and a garden hose, ready for operation.
Operating Instructions
Understanding the Display and Buttons
The Galcon 9001D features an LCD display and six control buttons for programming and manual operation.

Image: A detailed view of the Galcon 9001D's LCD screen showing time and programming indicators, along with the six blue control buttons for 'mode', 'set', and navigation.
- MODE Button: Cycles through programming modes (Time, Duration, Days, Cycle).
- SET Button: Confirms selections and enters programming sub-menus.
- Arrow Buttons (←, →): Navigate between settings or adjust values.
- Plus (+) / Minus (-) Buttons: Increase or decrease numerical values.
Setting the Current Time
- Press the MODE button until 'Time' is displayed.
- Press SET. The hour will flash.
- Use the + or - buttons to adjust the hour.
- Press the → button to move to minutes, then adjust with + or -.
- Press SET to confirm the time.
Programming Watering Schedules
The timer allows for up to four start times per day, with weekly or daily programming options.
- Set Duration: Press MODE until 'Duration' is displayed. Press SET and use +/- to set the watering duration (1 minute to 12 hours). Press SET to confirm.
- Set Days: Press MODE until 'Days' is displayed. Press SET. Use ←/→ to select specific days of the week or a daily cycle. Use +/- to activate/deactivate days. Press SET to confirm.
- Set Cycle (Start Times): Press MODE until 'Cycle' is displayed. Press SET. Use ←/→ to select one of the four available start times. Use +/- to set the desired start time. Repeat for additional start times. Press SET to confirm all cycles.
Manual Operation
To manually turn the water on or off:
- Press the button labeled 'manual' (often indicated by a water droplet icon).
- The valve will open, and water will flow.
- Press the 'manual' button again to close the valve and stop the water flow.
Rain-Off Suspension
To temporarily suspend watering due to rain or other reasons:
- Press the button labeled 'rain off' (often indicated by a cloud icon).
- The timer will suspend all programmed watering cycles for a set period (e.g., 24, 48, 72 hours). Use +/- to adjust the suspension duration.
- To cancel rain-off mode, press the 'rain off' button again.
Maintenance
Battery Replacement
When the low battery indicator appears on the LCD, replace the 9-volt battery promptly to ensure continuous operation. Follow the battery installation steps outlined in the Setup section.
Cleaning
Periodically inspect the inlet screen filter for debris. If clogged, remove the timer from the hose bib, clean the filter under running water, and reattach. Wipe the exterior of the timer with a damp cloth; do not use abrasive cleaners.
Winterization
Before the first frost, disconnect the timer from the hose bib and hose. Remove the 9-volt battery. Store the timer in a dry, frost-free location indoors. Failure to do so may result in damage due to freezing water.
Troubleshooting
- Timer not turning on: Check battery installation and ensure the battery is new and fully charged.
- No water flow: Ensure the hose bib is fully open. Check for clogs in the inlet filter. Verify that the timer is not in 'rain off' mode or that the program is correctly set.
- Leaking connections: Ensure all connections are hand-tightened. Check rubber washers for proper seating and damage. Replace washers if necessary.
- Incorrect watering schedule: Review your programmed settings for duration, days, and start times. Ensure the current time and day are set correctly on the timer.
- Display not working: Replace the battery. If the issue persists, contact customer support.
Specifications
| Feature | Specification |
|---|---|
| Model Number | 9001D |
| Operating Pressure | 15-145 PSI (1-10 Bars) |
| Watering Duration | 1 minute to 12 hours |
| Start Times | Up to 4 per day |
| Power Source | One 9-volt alkaline battery |
| Inlet/Outlet | 3/4" FHT inlet, MHT outlet |
| Dimensions (D x W x H) | 10.2 x 15.2 x 16.5 cm (approx.) |
| Item Weight | 318 Grams |
| Material | Durable plastic (Crystal refers to LCD) |

Image: The Galcon 9001D timer with its key dimensions (height, width, depth) indicated in centimeters.
Warranty and Support
For warranty information or technical support, please refer to the documentation provided with your purchase or contact Galcon customer service directly. Keep your proof of purchase for warranty claims.
Disposal Information
This product contains electronic components and a battery. Do not dispose of it with general household waste. Please follow local regulations for the proper disposal of electronic waste and batteries to protect the environment.