1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the Blodgett 37058 Relay. This component is a genuine OEM replacement part designed for specific Blodgett equipment. Adhering to these instructions ensures safe and reliable performance.

2. Safety Information

WARNING: Electrical components can cause serious injury or death if not handled properly. Always follow these safety precautions:

  • Disconnect all power to the equipment before installing, servicing, or removing the relay.
  • Installation and maintenance should only be performed by qualified and authorized personnel.
  • Ensure proper grounding of all electrical connections.
  • Verify that the replacement relay specifications match the original component and equipment requirements.
  • Do not operate the equipment with damaged or improperly installed components.
  • Wear appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.

3. Product Overview

The Blodgett 37058 is a Double Pole Single Throw (DPST) electromechanical relay designed for switching electrical circuits. It operates at 24 Volts and has a current rating of 25 Amps. This relay is an integral part of various Blodgett commercial oven and steamer systems, ensuring reliable control over electrical loads.

Front view of an industrial electromechanical relay, showing terminals and specifications. Note: Image depicts a generic industrial relay, not specifically branded Blodgett.

Figure 1: Front view of an industrial electromechanical relay. This image illustrates a typical relay component, which functions similarly to the Blodgett 37058. The relay features multiple terminals for electrical connections and displays operational specifications on its casing.

Side view of an industrial electromechanical relay, showing mounting features and terminal arrangement. Note: Image depicts a generic industrial relay, not specifically branded Blodgett.

Figure 2: Side view of an industrial electromechanical relay. This perspective highlights the relay's compact design and the arrangement of its terminals, which are crucial for proper wiring and installation within equipment.

4. Specifications

The following table details the technical specifications for the Blodgett 37058 Relay:

FeatureSpecification
Model Number37058
BrandBlodgett
Relay TypeDPST (Double Pole Single Throw)
Current Rating25 Amps
Maximum Switching Voltage24 Volts
Contact TypeNormally Open
Contact MaterialSilver Alloy
Connector TypeScrew
Mounting TypeDIN Rail Mount
Number of Terminals3
Operation ModeAutomatic
Item Weight3.2 ounces
Product Dimensions4 x 4 x 6 inches

5. Installation

Proper installation is critical for the safe and effective operation of the Blodgett 37058 Relay. This procedure should only be carried out by a qualified technician.

  1. Power Disconnection: Before beginning any work, ensure that the main power supply to the equipment is completely disconnected and locked out according to safety protocols. Verify zero voltage with a multimeter.
  2. Locate Existing Relay: Identify the relay to be replaced within the equipment's control panel. Note its orientation and wiring configuration. It is recommended to take photographs or draw a wiring diagram before removal.
  3. Remove Old Relay: Carefully disconnect all wires from the old relay's terminals. Note the terminal markings and corresponding wire connections. Remove the old relay from its DIN rail mount or mounting bracket.
  4. Mount New Relay: Install the Blodgett 37058 Relay onto the designated DIN rail or mounting location. Ensure it is securely fastened.
  5. Wire Connections: Connect the electrical wires to the new relay's screw terminals according to the original wiring diagram. Ensure all connections are tight and secure. Double-check that the 24 Volt control circuit and 25 Amp load circuits are correctly wired to the appropriate terminals.
  6. Verify Installation: Visually inspect all connections for correctness and security. Ensure no loose wires or potential short circuits.
  7. Restore Power: Once installation is complete and verified, restore power to the equipment. Observe the relay's operation to confirm proper functionality.

Refer to the specific equipment's service manual for detailed wiring diagrams and installation procedures.

6. Operation

The Blodgett 37058 Relay operates automatically as part of the equipment's control system. When the 24 Volt control voltage is applied to the relay coil, it energizes, causing the internal contacts to close. This action completes the circuit for the connected load, allowing current (up to 25 Amps) to flow. When the control voltage is removed, the coil de-energizes, and the contacts return to their normally open state, interrupting the load circuit.

This relay is designed for reliable switching in applications requiring a robust electromechanical interface between a low-power control signal and a higher-power load.

7. Maintenance

The Blodgett 37058 Relay is a sealed component and generally requires minimal maintenance. However, periodic inspection of the relay and its connections is recommended as part of routine equipment maintenance.

  • Visual Inspection: Regularly inspect the relay for any signs of physical damage, discoloration, or overheating. Check for loose or corroded terminal connections.
  • Environmental Conditions: Ensure the relay operates within its specified environmental conditions (temperature, humidity) to prevent premature failure.
  • Cleaning: If necessary, gently clean the exterior of the relay with a dry, lint-free cloth. Do not use solvents or abrasive cleaners.
  • Replacement: If the relay shows signs of wear, intermittent operation, or failure, it should be replaced immediately with a genuine Blodgett 37058 replacement part.

Always disconnect power before performing any inspection or maintenance.

8. Troubleshooting

If the equipment is not functioning correctly and the relay is suspected as the cause, consider the following troubleshooting steps:

  • No Operation:
    • Verify that the equipment has power.
    • Check the 24 Volt control signal to the relay coil. Use a multimeter to confirm voltage presence when the relay should be active.
    • Inspect wiring for loose connections or breaks.
    • Test the continuity of the relay contacts when energized (with power disconnected and relay removed, if possible, or using appropriate safety measures).
  • Intermittent Operation:
    • Check for loose terminal connections.
    • Inspect for signs of overheating or arcing at the contacts, which may indicate a failing relay.
    • Ensure the control voltage is stable and within specifications.
  • Relay Stuck Open or Closed:
    • This often indicates internal mechanical failure or welded contacts. The relay should be replaced.

If troubleshooting does not resolve the issue, consult a qualified service technician or Blodgett customer support.

9. Warranty and Support

As a genuine Blodgett OEM replacement part, the 37058 Relay is designed for optimal compatibility and performance with Blodgett equipment. For warranty information or technical support, please refer to the documentation provided with your Blodgett appliance or contact Blodgett customer service directly. Using genuine OEM parts helps maintain the safety, reliability, and performance of your equipment.

For further assistance, visit the official Blodgett website or contact their authorized service centers.

© 2023 Blodgett. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.