1. Introduction
The Buderus Logafix BD-1 Thermostatic Head is a compact, ergonomic, and elegant device designed to regulate the temperature of radiators. It is compatible with all Logatrend flat valve radiators and compact radiators equipped with Danfoss valves, including Danfoss RA series thermostatic valves. This manual provides essential information for the proper installation, operation, and maintenance of your thermostatic head.
2. Product Features
- Ergonomic and compact design for ease of use and aesthetic integration.
- Wide compatibility with Logatrend flat valve radiators and Danfoss compact radiators.
- Also compatible with Danfoss RA series thermostatic valves.
- Adjustable temperature range from 6 °C to 28 °C, allowing precise climate control.
- Clear and easily readable set value from any angle, whether mounted on a thermostatic valve body or a compact radiator valve.
3. Package Contents
Please check the package for the following items:
- 1 x Buderus Logafix BD-1 Thermostatic Head
- Instruction Manual (this document)
If any items are missing or damaged, please contact your retailer or Buderus customer support.
4. Safety Information
Read all instructions carefully before installation and use. Keep this manual for future reference.
- Ensure the heating system is depressurized and cooled down before attempting installation or maintenance.
- Installation should be performed by a qualified professional if you are unsure.
- Do not expose the thermostatic head to extreme temperatures or direct sunlight for prolonged periods.
- Do not attempt to disassemble or repair the unit yourself. Contact qualified service personnel.
- Keep out of reach of children.
5. Setup and Installation
The Buderus Logafix BD-1 thermostatic head is designed for easy installation on compatible radiator valves. Ensure the valve body is clean and free from debris before attachment.
- Ensure the heating system is turned off and the radiator is cool.
- If replacing an old thermostatic head, carefully unscrew and remove it.
- Align the Buderus Logafix BD-1 thermostatic head with the valve body. The head typically connects via a flange connection or a screw-on mechanism.
- Gently push the head onto the valve and secure it by tightening the connection nut or ring until it is firm. Do not overtighten.
- Once installed, you can turn the heating system back on.

Figure 5.1: The Buderus Logafix BD-1 Thermostatic Head shown with optional screw connections for various valve types. This image illustrates how the head connects to a radiator valve, highlighting the flange connection point.
6. Operating Instructions
The thermostatic head allows you to set the desired room temperature by rotating the dial.

Figure 6.1: Front view of the Buderus Logafix BD-1 Thermostatic Head, showing the Buderus logo and the temperature setting dial with numerical and snowflake indicators. The dial can be rotated to adjust the desired room temperature.
- Temperature Scale: The dial features a scale typically ranging from a snowflake symbol (frost protection, approx. 6 °C) to numbers indicating higher temperatures, up to 28 °C.
- Setting Temperature: Rotate the dial to align the desired temperature setting with the indicator mark on the head.
- Frost Protection: Set the dial to the snowflake symbol (*) to activate frost protection, which maintains a minimum temperature (around 6 °C) to prevent pipes from freezing.
- Neutral Position: The head also features a neutral position, typically marked '0', which fully closes the valve and stops heat flow to the radiator.
- Optimal Use: For optimal energy efficiency, avoid setting the thermostat to maximum unless necessary. Adjust the setting based on your comfort level and external temperature.
7. Maintenance
The Buderus Logafix BD-1 Thermostatic Head requires minimal maintenance.
- Cleaning: Wipe the exterior of the thermostatic head with a soft, damp cloth. Do not use abrasive cleaners or solvents, as these can damage the surface.
- Dust Accumulation: Ensure that dust does not accumulate around the sensor area (usually located at the back or bottom of the head), as this can affect temperature readings.
- Regular Checks: Periodically check that the head is securely attached to the valve body.
8. Troubleshooting
If you experience issues with your thermostatic head, consider the following common solutions:
- Radiator not heating:
- Check if the thermostatic head is set to a temperature higher than the current room temperature.
- Ensure the valve pin is not stuck. Try rotating the head from maximum to minimum several times to free the pin.
- Verify that the main heating system is operational and supplying hot water to the radiator.
- Radiator too hot/cold:
- The thermostatic head might be obstructed by curtains, furniture, or other objects, preventing it from accurately sensing room temperature. Ensure clear airflow around the head.
- Recalibrate your comfort setting by adjusting the dial gradually.
- Head feels loose:
- Gently tighten the connection nut or ring. Do not overtighten.
If the problem persists, contact a qualified heating technician or Buderus customer support.
9. Specifications
| Parameter | Value |
|---|---|
| Model Number | 7738306436 |
| Manufacturer | Buderus |
| Temperature Range | 6 °C to 28 °C |
| Material | Plastic (PLA) |
| Dimensions (Package) | 9.6 x 6 x 5.6 cm |
| Weight (Item) | 80 grams |
| Batteries Required | No |
| ASIN | B00E952YTC |
10. Warranty and Support
Buderus products are manufactured to high-quality standards. For information regarding warranty coverage, please refer to the warranty card included with your purchase or visit the official Buderus website.
For technical support, spare parts, or service inquiries, please contact your local Buderus dealer or authorized service center. You can find contact information on the official Buderus website or through your product retailer.
Official Buderus Website: www.buderus.com