LASCO 06-9123

LASCO 06-9123 Angle Stop Adapter Tee User Manual

Model: 06-9123 | Brand: LASCO

Introduction

This manual provides instructions for the proper installation, operation, and maintenance of the LASCO 06-9123 Angle Stop Adapter Tee. This lead-free brass fitting is designed to add an additional water line to an existing single outlet supply valve. Please read these instructions carefully before installation to ensure safe and correct usage.

Safety Information

  • Always shut off the main water supply before beginning any plumbing work.
  • Wear appropriate personal protective equipment, such as safety glasses and gloves.
  • Ensure all connections are tight to prevent leaks. Do not overtighten, as this can damage threads or components.
  • This product is made from lead-free rough brass and is approved for use in all states.
  • If you are unsure about any step, consult a qualified plumber.

Package Contents

  • 1 x LASCO 06-9123 Angle Stop Adapter Tee

Specifications

Model Number 06-9123
Material Lead-Free Brass
Connector Type Tee
Connections 3/8-inch OD Compression x 3/8-inch OD Compression x 1/2-inch Slip Joint
Dimensions (L x W x H) 0.81 x 1.16 x 2.32 inches
Item Weight 1.12 ounces (approx. 0.07 lbs)

Installation Instructions

Follow these steps to install the LASCO 06-9123 Angle Stop Adapter Tee:

  1. Prepare the Area:

    Locate the existing single outlet supply valve. Ensure there is sufficient space for the adapter tee and the additional water line.

    LASCO 06-9123 Angle Stop Adapter Tee

    Image: The LASCO 06-9123 Angle Stop Adapter Tee, showing its three connection points. This image illustrates the overall design of the product.

  2. Shut Off Water Supply:

    Turn off the main water supply to the area where you will be working. Open a nearby faucet to relieve any pressure in the lines.

  3. Disconnect Existing Line:

    Carefully disconnect the existing water supply line from the single outlet supply valve. Have a towel ready to catch any residual water.

  4. Install Adapter Tee:

    Connect one of the 3/8-inch OD compression ends of the adapter tee to the existing supply valve. Hand-tighten first, then use a wrench to secure, being careful not to overtighten.

    Note: The adapter tee features two 3/8-inch OD compression connections and one 1/2-inch slip joint connection. The compression connections are typically used for flexible supply lines, while the slip joint is often used for rigid pipes or specific appliance connections.

  5. Reconnect Existing Line:

    Connect the previously disconnected water supply line to the other 3/8-inch OD compression end of the adapter tee. Secure tightly.

  6. Connect New Water Line:

    Connect your new water line (e.g., for a bidet, humidifier, or other appliance) to the 1/2-inch slip joint connection of the adapter tee. Ensure a proper seal, using thread sealant or tape if required for the specific connection type.

    Close-up of LASCO 06-9123 Adapter Tee connections

    Image: A close-up view of the adapter tee, highlighting the different connection types (3/8-inch compression and 1/2-inch slip joint) for clarity during installation.

  7. Check for Leaks:

    Slowly turn the main water supply back on. Carefully inspect all connections for any signs of leaks. Tighten any leaking connections slightly until the leak stops. Do not overtighten.

Operation

Once installed, the LASCO 06-9123 Angle Stop Adapter Tee functions as a passive splitter, allowing water to flow to both connected lines simultaneously from a single supply valve. There are no moving parts or controls on the adapter tee itself.

Maintenance

The LASCO 06-9123 Angle Stop Adapter Tee requires minimal maintenance. Periodically inspect the connections for any signs of corrosion or leaks. If a leak is detected, ensure the connection is secure. If the leak persists, the fitting may need to be re-sealed or replaced.

Troubleshooting

  • Leaks at Connections:

    Ensure all compression nuts are tightened properly. For slip joint connections, verify that the washer is correctly seated and the nut is snug. Avoid overtightening, which can damage the fitting or tubing. If using thread tape or sealant, ensure it was applied correctly.

  • Insufficient Water Flow:

    Check that the main water supply valve is fully open. Inspect connected lines for kinks or obstructions. The adapter tee itself does not restrict flow significantly.

Warranty Information

This LASCO product comes with a 1 Year Limited Warranty from the date of purchase. This warranty covers defects in material and workmanship under normal use and service. For warranty claims or further details, please contact LASCO customer support.

Customer Support

For technical assistance, replacement parts, or general inquiries, please visit the official LASCO website or contact their customer service department. Refer to your product packaging or the LASCO website for the most current contact information.

LASCO Official Website: www.lascofittings.com

Related Documents - 06-9123

Preview Larsen Supply Co. Ceramic Stems Catalog
Comprehensive catalog of ceramic faucet stems and related repair parts from Larsen Supply Co. (LASCO), featuring detailed specifications, model numbers, and compatibility information for various brands.
Preview GENEBRE 0047 Female L Elbow Connector - Technical Specifications & Assembly
Detailed technical specifications, dimensions, and assembly instructions for the GENEBRE 0047 Female L Elbow Connector, designed for PE pipes and featuring the RAC-GE press system.
Preview Mastercool 72485-PRC Hydraulic Flaring Tool Operating Instructions and Guide
Comprehensive operating instructions and troubleshooting guide for the Mastercool 72485-PRC Universal Hydraulic Flaring Tool, covering push connect, GM fuel line, 45° double, and metric bubble flaring techniques. Includes replacement parts list.
Preview Perkin-Elmer Memory Access Controller Test Program 06-160R07 - Technical Specification
Perkin-Elmer Memory Access Controller Test Program (06-160R07) technical specification. This guide details the purpose, hardware requirements, loading, operation, and error handling for diagnosing Perkin-Elmer's Memory Access Controller in Series 32 computer systems. Includes patch information and related test programs.
Preview Kobalt 80V Sitting Worklight User Manual and Specifications
Comprehensive user manual for the Kobalt 80V Sitting Worklight (Model KWL 0080-06), including safety instructions, operating procedures, product specifications, troubleshooting, and warranty information.
Preview Sinkology Grace 34" Undermount Farmhouse Fireclay Kitchen Sink - Model SK451-34FC
Discover the Sinkology Grace 34-inch undermount farmhouse fireclay kitchen sink, designed for easy cleaning and maximum workspace. Features durable SureFire® fireclay, a single bowl, and available finishes like Crisp White and Summer Night. Includes detailed specifications, installation guidance, and warranty information.