1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of the OEM Upgraded Ruud Heat Pump Defrost Control Circuit Board & Sensor (Model: CECOMINOD040090, Part Number: 47-21517-88). This component is designed to replace original equipment in compatible Ruud heat pump systems, ensuring efficient defrost cycles and optimal system performance. Please read this manual thoroughly before attempting any installation or service.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death. Read this manual thoroughly before installing or servicing this equipment.
- Always disconnect power to the heat pump unit before installing or servicing the control board.
- Only qualified HVAC technicians should perform installation and service.
- Wear appropriate personal protective equipment (PPE), including safety glasses and gloves.
- Ensure all wiring connections are secure and comply with local electrical codes.
- Do not bypass any safety devices.
- Handle the circuit board by its edges to avoid damaging electronic components due to static electricity.
3. Product Overview and Components
The Ruud Heat Pump Defrost Control Circuit Board is a critical component responsible for managing the defrost cycle of your heat pump, preventing ice buildup on the outdoor coil. The package includes the main circuit board and two associated sensors.

Figure 3.1: OEM Upgraded Ruud Heat Pump Defrost Control Circuit Board and Sensors.
This image displays the complete product. On the left is the rectangular circuit board, populated with various electronic components such as relays, resistors, capacitors, and an LED indicator. Several connection terminals are visible along the top edge. To the right of the circuit board are two separate sensor assemblies, each consisting of a sensor probe attached to a length of black wire, terminating in a white connector. One sensor appears to be a temperature sensor, while the other is likely a defrost sensor.
Key Features:
- Direct OEM replacement for compatible Ruud heat pump models.
- Integrated diagnostic LED for easier troubleshooting.
- Includes necessary sensors for defrost operation.
- Designed for reliable performance in heat pump defrost cycles.
4. Specifications
| Specification | Value |
|---|---|
| Model Number | CECOMINOD040090 |
| Part Number | 47-21517-88 |
| Brand | Ruud |
| Product Dimensions | 6 x 4 x 6 inches |
| Item Weight | 0.44 Pounds (7.04 ounces) |
| Maximum Supply Voltage | 12 Volts (DC) |
| Date First Available | July 4, 2013 |
5. Setup and Installation
Installation of this defrost control board requires knowledge of HVAC electrical systems. It is strongly recommended that installation be performed by a certified HVAC technician.
Installation Steps (For Qualified Technicians Only):
- Power Disconnection: Locate the main power disconnect for the heat pump unit and turn off all power. Verify power is off using a multimeter.
- Access Control Panel: Open the heat pump's outdoor unit control panel to access the existing defrost board.
- Document Wiring: Before disconnecting any wires, take clear photos or draw a detailed diagram of all existing wiring connections to the old board. Note the position of each wire and its corresponding terminal.
- Remove Old Board: Carefully disconnect all wires and mounting screws securing the old defrost board. Remove the old board.
- Install New Board: Mount the new OEM Upgraded Ruud Defrost Control Circuit Board in the same location using the existing mounting hardware.
- Connect Wiring: Refer to your documented wiring diagram and connect all wires to the corresponding terminals on the new board. Ensure all connections are tight and secure. Pay close attention to the sensor connections (DF1, DF2, OAT, etc., as labeled on the board).
- Install Sensors: Install the new defrost and outdoor ambient temperature sensors in their designated locations within the heat pump unit, ensuring proper contact and placement as per the heat pump's service manual.
- Secure Panel: Close and secure the control panel cover.
- Restore Power: Restore power to the heat pump unit.
- Test Operation: Initiate a test cycle to verify proper defrost operation. Observe the diagnostic LED for any error codes (refer to Section 7: Troubleshooting).
Note: Specific wiring diagrams for your heat pump model should be consulted in conjunction with this general guide.
6. Operating Principles
The defrost control board continuously monitors the outdoor coil temperature and ambient air temperature using the connected sensors. When conditions indicate ice buildup (e.g., outdoor coil temperature drops significantly below freezing while the ambient temperature is also low), the board initiates a defrost cycle. During a defrost cycle, the heat pump temporarily reverses its operation to heat the outdoor coil, melting any accumulated ice. Once the coil reaches a predetermined temperature or a set time limit expires, the board terminates the defrost cycle, and the heat pump returns to normal heating operation.
The integrated diagnostic LED provides visual feedback on the board's status and can indicate specific operational modes or fault conditions. Consult the troubleshooting section for LED blink codes.
7. Maintenance
The defrost control board itself requires minimal maintenance. However, regular inspection of the heat pump system is recommended to ensure optimal performance and longevity of all components, including the defrost board.
- Annual Inspection: Have a qualified technician inspect the heat pump system annually. This includes checking electrical connections, sensor integrity, and overall system operation.
- Cleanliness: Ensure the control panel area is free from dust, debris, and moisture. While the board is designed to be robust, excessive accumulation can affect performance.
- Wiring Integrity: Periodically check for any signs of wear, fraying, or loose connections in the wiring connected to the board.
8. Troubleshooting
This section provides general troubleshooting steps. For complex issues, contact a qualified HVAC technician.
Common Issues and Solutions:
- Heat Pump Not Defrosting:
- Check power supply to the unit and the board.
- Inspect sensor connections and ensure sensors are properly placed.
- Observe the diagnostic LED for specific error codes related to defrost failure or sensor issues.
- Verify that the outdoor coil is actually accumulating ice under appropriate conditions.
- Heat Pump Constantly Defrosting:
- Check sensor readings; a faulty sensor might be reporting incorrect temperatures.
- Ensure proper airflow over the outdoor coil.
- Consult the diagnostic LED for continuous defrost signals.
- No Power to Board / Board Not Responding:
- Verify main power supply to the heat pump.
- Check fuses on the heat pump unit and any associated circuit breakers.
- Ensure all low-voltage connections to the board are secure.
Diagnostic LED (LED 031):
The board features a diagnostic LED (labeled "LED 031" in the image) that provides status and error codes. Refer to your heat pump's specific service manual or the board's technical documentation for a complete list of LED blink codes and their meanings. Typically, a steady light indicates normal operation, while specific blink patterns indicate different fault conditions (e.g., sensor fault, defrost cycle in progress, etc.).
9. Warranty and Support
For specific warranty information regarding the OEM Upgraded Ruud Heat Pump Defrost Control Circuit Board & Sensor, please refer to the documentation provided by your original point of purchase or contact the seller directly. Warranty terms typically cover manufacturing defects for a specified period.
If you require technical support or assistance with troubleshooting beyond the scope of this manual, it is recommended to contact a certified HVAC professional or the customer support of the vendor from whom you purchased the product. Provide them with your product model number (CECOMINOD040090) and part number (47-21517-88) for efficient service.