Introduction
This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Friedrich PDE09K3SG 42-inch Packaged Terminal Air Conditioner. Please read this manual thoroughly before using the unit and retain it for future reference.

Figure 1: Friedrich PDE09K3SG Packaged Terminal Air Conditioner. This image displays the front view of the unit, highlighting its compact design and air intake/output grilles.
Important Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury to persons.
- Read all instructions before using this appliance.
- Do not operate any appliance with a damaged cord or plug.
- Do not block air openings.
- Ensure proper grounding.
- Refer all servicing to qualified service personnel.
Setup and Installation
The Friedrich PDE09K3SG is designed for through-the-wall installation. Proper installation is crucial for optimal performance and safety. It is recommended that installation be performed by a qualified technician.
Unpacking
- Carefully remove the unit from its packaging.
- Inspect the unit for any shipping damage. Report any damage immediately to your dealer.
- Ensure all components listed in the packing list are present.
Location Requirements
- Install the unit in a wall sleeve designed for PTAC units.
- Ensure adequate clearance around the unit for proper airflow.
- The unit requires a dedicated 230/208 Volt electrical circuit.
Electrical Connection
This unit operates on 230/208 Volts. Consult a qualified electrician for proper wiring and connection to ensure compliance with local electrical codes.
Operating Instructions
The Friedrich PDE09K3SG unit is typically controlled by a wall-mounted thermostat for precise temperature management.
Thermostat Controls
The wall thermostat allows you to select operating modes and adjust temperature settings.
- System Mode: Use the system switch to select between "Cool", "Heat", "Off", or "Em. Heat" (Emergency Heat) modes.
- Fan Mode: Use the fan switch to select "Auto" (fan runs only when heating/cooling) or "On" (fan runs continuously).
- Temperature Adjustment: Use the Up and Down arrow buttons to set your desired room temperature. The digital display will show the current and set temperatures.

Figure 2: Close-up of the Friedrich PTAC unit's internal control panel, indicating it is controlled by a wall thermostat. This panel is typically hidden behind a cover.
Airflow Management
The unit features a large vent for efficient air distribution. Ensure that the vent is not obstructed by furniture, curtains, or other objects to maintain optimal performance.
Maintenance
Regular maintenance ensures the longevity and efficiency of your PTAC unit.
Air Filter Cleaning
The unit is equipped with an antimicrobial air filter. A clean filter is essential for efficient operation and good indoor air quality.
- Turn off the unit at the wall thermostat or circuit breaker before cleaning.
- Locate and remove the air filter (typically behind the front grille).
- Clean the filter with warm, soapy water. Rinse thoroughly and allow it to air dry completely before reinstallation.
- Reinstall the dry filter and restore power to the unit.
- Frequency: Clean the filter monthly, or more often if the unit is used frequently or in dusty environments.
Coil Cleaning
The DiamonBlue Corrosion Protection helps protect the coils, but periodic cleaning by a qualified technician is recommended to remove dirt and debris that can accumulate over time.
Troubleshooting
Before calling for service, review the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on. | No power; thermostat set to "Off". | Check circuit breaker; ensure thermostat is set to "Cool" or "Heat". |
| Insufficient cooling/heating. | Dirty air filter; obstructed airflow; incorrect thermostat setting. | Clean air filter; remove obstructions from vents; adjust thermostat. |
| Unusual noise. | Loose parts; debris in fan. | Turn off unit and inspect for loose components or debris. If noise persists, contact service. |
If troubleshooting steps do not resolve the issue, contact qualified service personnel.
Specifications
| Feature | Detail |
|---|---|
| Model Number | PDE09K3SG (Item Model Number: 292279) |
| Brand | Friedrich |
| Cooling Capacity | 9,400 BTU (0.78 Tons) |
| Heating Type | Electric Heat |
| Voltage | 230/208 Volts |
| Dimensions (D x W x H) | 21.5" x 42" x 16" |
| Item Weight | 127 pounds |
| Refrigerant | R 410A |
| Special Features | Heating and Cooling Function, DiamonBlue Corrosion Protection, Antimicrobial Air Filter |
| Seasonal Energy Efficiency Ratio (SEER) | 13 |
| Color | White |
Warranty and Support
For warranty information and technical support, please refer to the documentation included with your purchase or visit the official Friedrich website. Keep your purchase receipt for warranty claims.
Manufacturer: Friedrich
Included Components: Assembly Guide