MSA ALTAIR 4X Multi-Gas Detector

Model: 10107602 User Manual

Introduction and Safety Information

The MSA ALTAIR 4X Multi-Gas Detector is a robust and reliable instrument designed to monitor ambient air for the presence of combustible gases (LEL), Oxygen (O2), Carbon Monoxide (CO), and Hydrogen Sulfide (H2S). This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device. Always read and understand these instructions before using the detector.

Important Safety Precautions:

MSA ALTAIR 4X Multi-Gas Detector showing display with gas readings

This image displays the MSA ALTAIR 4X Multi-Gas Detector, a compact, handheld device. The front panel features a large digital display showing readings for COMB/EX (combustible gases), O2 (oxygen), CO (carbon monoxide), and H2S (hydrogen sulfide). Above the display are control buttons and LED indicators. The device has a rugged, charcoal-colored casing.

Product Features and Components

The ALTAIR 4X is equipped with advanced MSA XCell sensors for rapid and accurate gas detection. Its robust design ensures durability in harsh environments.

Setup and Initial Operation

1. Unpacking and Inspection

Carefully remove the ALTAIR 4X detector from its packaging. Inspect the device for any visible damage. Ensure all components listed in the packing slip are present.

2. Charging the Battery

Before first use, fully charge the detector's battery. Connect the charging cable to the detector and plug the charger into a power outlet. The charging indicator will show the charging status. A full charge typically takes several hours and provides up to 24 hours of operation.

3. Powering On/Off

4. Initial Bump Test and Calibration

It is critical to perform a bump test before each day's use to verify sensor and alarm functionality. Full calibration should be performed regularly according to manufacturer recommendations and local regulations (e.g., every 3-6 months). Refer to the detailed calibration instructions provided with your calibration gas kit.

Operating the Detector

1. Understanding the Display

The large LCD displays real-time gas concentrations for LEL, O2, CO, and H2S. It also shows battery status, alarm indicators, and other operational messages.

2. Alarm Conditions

The ALTAIR 4X features multiple alarm types:

When an alarm activates, immediately follow your company's safety protocols for hazardous gas exposure or emergency situations.

Worker wearing an MSA ALTAIR 4X Multi-Gas Detector clipped to their safety vest in an industrial setting

A worker is shown in an industrial environment, wearing an MSA ALTAIR 4X Multi-Gas Detector clipped to their safety vest, demonstrating typical usage.

Maintenance

Proper maintenance ensures the longevity and accuracy of your ALTAIR 4X detector.

1. Cleaning

Clean the exterior of the detector regularly with a damp cloth. Do not use abrasive cleaners or solvents. Ensure sensor inlets are clear of debris.

2. Sensor Care

MSA XCell sensors are designed for durability, but proper care is essential. Avoid exposing sensors to extreme temperatures or prolonged high concentrations of gases outside their specified range, as this can reduce sensor life or cause damage.

3. Battery Care

To maximize battery life, avoid fully discharging the battery frequently. Store the detector in a cool, dry place when not in use, and ensure it is charged periodically if stored for long durations.

4. Storage

Store the detector in a clean, dry environment within the specified temperature range. Protect it from physical shock and direct sunlight.

Troubleshooting

This section addresses common issues you might encounter with your ALTAIR 4X detector.

ProblemPossible CauseSolution
Detector does not power on.Low or dead battery.Charge the battery fully.
Sensor error message displayed.Sensor fault, expired sensor, or calibration issue.Perform a bump test. If error persists, attempt calibration. If still unresolved, contact MSA support for sensor replacement.
Alarms not sounding/flashing.Alarm settings disabled, or speaker/LED fault.Check alarm settings in the menu. Perform a bump test to verify alarm function. If still no alarm, contact MSA support.
Inaccurate gas readings.Needs calibration, sensor contamination, or sensor nearing end-of-life.Perform a fresh air calibration, then a full calibration. Ensure sensor inlets are clean. If issues persist, sensor replacement may be required.

For issues not listed here or if solutions do not resolve the problem, please contact MSA customer support.

Specifications

FeatureDetail
Model Number10107602
Detected GasesLEL (Combustible), O2 (Oxygen), CO (Carbon Monoxide), H2S (Hydrogen Sulfide)
Power SourceBattery Powered (24-hour battery life)
Alarm TypeAudible, Visual (LED), Vibrating, Man-Down
Sensor TypeMSA XCell Sensors
Ingress Protection (IP) RatingIP67
Drop Resistance20-foot drop test certified
Operating Temperature Range-4°F to 122°F (-20°C to 50°C)
Item Weight0.55 Pounds (approx. 8.8 ounces)
Product Dimensions10.39 x 5 x 3.94 inches (packaging dimensions)

Warranty and Support

The MSA ALTAIR 4X Multi-Gas Detector comes with a 3-year warranty and a performance guarantee, ensuring reliability and peace of mind.

For technical support, warranty claims, or service, please contact MSA Safety Incorporated directly. Visit the official MSA website for contact information and additional resources.

Visit the MSA Safety Store on Amazon

Related Documents - 10107602

Preview MSA ALTAIR Pro Single Gas Detector Operating Manual - Safety and Usage Guide
This operating manual provides detailed instructions, safety guidelines, calibration procedures, and troubleshooting for the MSA ALTAIR Pro Single Gas Detector. Learn how to use and maintain your gas detection instrument effectively.
Preview MSA ALTAIR Pump Probe: Durable Gas Detector for Hazardous Environments
Explore the MSA ALTAIR Pump Probe, a rugged and reliable gas detection instrument. Learn about its key features, technical specifications, approvals, and ordering information for industrial safety applications.
Preview GALAXY GX2 Automated Test System Quick Start Guide | MSA
Quick start guide for the MSA GALAXY GX2 Automated Test System, covering system components, setup, initial startup, default parameters, electronic cylinder holder, multi-unit charger, and testing procedures for ALTAIR detectors.
Preview MSA GALAXY GX2 Automated Test System for Gas Detectors
The MSA GALAXY GX2 Automated Test System offers simple, intelligent testing and calibration for MSA ALTAIR and ALTAIR PRO single-gas detectors, and ALTAIR 4XR and ALTAIR 5X multi-gas detectors. It features an easy-to-use interface, automated testing, and comprehensive fleet management capabilities.
Preview MSA ALTAIR io 4 Gas Detection Wearable: Standards Compliance Certifications and Notices
This document provides details on the MSA ALTAIR io 4 Gas Detection Wearable, covering device cleaning procedures, important safety notices including Bluetooth and radio information, ingress protection, charging guidelines, and comprehensive certifications and markings from bodies like UL, CAN/CSA, ATEX, and IEC.
Preview MSA ALTAIR 5X and 5XIR Multigas Detector Operating Manual
Comprehensive operating manual for the MSA ALTAIR 5X and ALTAIR 5XIR Multigas Detectors, covering safety regulations, operation, maintenance, technical specifications, and troubleshooting for gas detection in industrial environments.