1. Introduction
The truMedic PL-009 is an electronic pulse unit designed for effective pain management. Utilizing Transcutaneous Electrical Nerve Stimulation (TENS), it stimulates muscles and nerves, improving joint mobility and alleviating muscle stiffness, soreness, aches, and pains. This portable and lightweight device offers a convenient solution for electrotherapy pain management.
The unit features preset massage programs tailored for different muscle groups, allowing for customized treatment. Users can adjust speed and intensity, and choose between 'Massage,' 'Beat,' or 'Knead' settings to control the rhythm and sensation of their therapy session. Its compact design makes it ideal for on-the-go use.

Figure 1: TruMedic TENS Electronic Pulse Unit PL-009
Video 1: Official product video demonstrating the features and benefits of the TruMedic TENS Electronic Pulse Unit.
2. Safety Information
Please read and understand all safety information before using the truMedic PL-009 unit.
- This product should not be used near water.
- Individuals with pacemakers or other electronic medical devices should not use this product.
- Do not use for longer than 30 minutes at a time.
- Consult with your healthcare provider before using this or any home health care product, especially if you have a serious medical condition.
- Do not use if you have acute disease, malignant tumors, infectious disease, are pregnant, have any implanted devices, heart disease, high fever, abnormal blood pressure, lack of skin sensation or numbness in extremities, fever, or any abnormal skin condition.
3. Package Contents
Verify that all the following items are included in your truMedic PL-009 package:
- TruMedic TENS Electronic Pulse Unit (PL-009)
- 4 Electrode Pads
- Lead Wires
- 4 AAA Batteries

Figure 2: Included components of the TruMedic PL-009
4. Setup
- Install Batteries: Carefully install the included 4 AAA batteries into the unit. Ensure correct polarity.
- Connect Lead Wires: With the unit turned off, plug one lead wire into one of the output ports on the top of the unit.
- Attach Electrode Pads: Attach the lead wire to the included reusable self-stick electrode pads.
- Apply Pads to Skin: Carefully peel the electrodes from their storage card and place the pads on clean, dry skin on either side of the painful area.

Figure 3: Proper connection of lead wires and pads
5. Operating Instructions
- Power On: Turn the thumbwheel directly below the lead wire to '1' to power on the unit. Verify that the letter 'P' appears on the screen, indicating power.
- Select Mode: Choose your desired massage program (e.g., Waist, Shoulder, Joint, Hand-Foot, Sole) or manual setting (Massage, Beat, Knead) using the corresponding buttons.
- Adjust Speed: Use the 'Speed +' and 'Speed -' buttons to adjust the pulse speed to your preference.
- Adjust Intensity: Slowly raise the power intensity using the thumbwheels. Start with a mild setting (e.g., 1) and gradually increase to a comfortable yet effective level (up to 10).
- Utilize Dual Channels: The unit has two separate channels, allowing you to use one side initially and then both sides on two different areas of your body simultaneously.
- Repeat Feature: The 'Repeat' button allows the unit to stay on the current program without cycling through to the next program in a preset sequence.

Figure 4: TruMedic PL-009 Control Panel
6. Maintenance
To ensure the longevity and optimal performance of your truMedic PL-009 unit:
- Keep the unit and electrode pads clean and dry. Wipe the unit with a soft, damp cloth as needed.
- Store the electrode pads on their original storage card after each use to maintain their adhesive quality.
- Replace electrode pads when they lose their stickiness or become worn.
- Remove batteries if the unit will not be used for an extended period.
7. Troubleshooting
If you experience issues with your truMedic PL-009 unit, consider the following:
- No Power: Ensure batteries are correctly installed and have sufficient charge. Replace batteries if necessary.
- No Sensation: Check that lead wires are securely plugged into the unit and the electrode pads. Ensure pads are firmly adhered to clean, dry skin. Gradually increase the intensity level.
- Weak Sensation: The electrode pads may be losing their conductivity. Try new pads. Ensure skin is clean and free of lotions or oils.
- Irregular Pulses: Check all connections. Ensure the unit is not exposed to extreme temperatures or humidity.
8. Specifications
Feature | Detail |
---|---|
Model Number | PL009 |
Product Dimensions | 7.75 x 2 x 0.75 inches |
Item Weight | 6.4 ounces |
Power Source | Battery Powered (4 AAA batteries, included) |
Material | Plastic |
Manufacturer | truMedic |
9. Warranty & Support
The truMedic PL-009 unit comes with a full parts and labor warranty for 90 days from the date of purchase.
For customer support or warranty inquiries, please contact truMedic at:
Customer Support Number: 800-694-7082