1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of the Johnson Controls P70AA-5C Pressure Control. This device is primarily designed for low pressure cut-out control, pump-down control, and capacity control in commercial refrigeration and air conditioning systems. It is compatible with most common refrigerants and can also be used in other non-corrosive fluid applications.
The P70AA-5C model is part of the P70, P72, and P170 series, offering robust performance for various pressure control needs.
2. Safety Information
Always observe safety precautions when working with electrical and pressure systems. Failure to follow these instructions could result in property damage, personal injury, or death.
- Disconnect all power to the system before installing or servicing the control.
- Ensure all wiring complies with local and national electrical codes.
- Do not exceed the specified electrical ratings of the control.
- Handle refrigerants and other fluids according to industry safety standards.
- Only qualified personnel should install and service this equipment.
3. Product Features
The Johnson Controls P70AA-5C Pressure Control incorporates several design features to ensure reliable and precise operation:
- All-steel case and cover: Provides durable, long-lasting protection for internal components.
- Sight-set calibrated pressure adjustment: Allows for visible pressure scale adjustment through the entire range without removing the cover (on NEMA 1 enclosure models).
- MICRO-SET differential option: Enables precise control for critical low pressure applications.
- Manual reset lockout option: Offers trip-free low pressure lockout that cannot be overridden or reset until pressure returns to the specified level.
- Limited knob adjustment option: Restricts control adjustment ranges to deter tampering and over-adjustment.

Figure 1: Johnson Controls P70AA-5C Pressure Control. This image shows the grey control box with the Johnson Controls logo and "PENN" label, connected to a brass fitting and coiled copper tubing, ending in a hexagonal nut fitting.
4. Setup and Installation
Proper installation is crucial for the optimal performance and longevity of the P70AA-5C Pressure Control. Refer to the system's specific wiring diagrams and local codes for detailed instructions.
- Mounting: Securely mount the control in a location free from excessive vibration, moisture, and extreme temperatures. Ensure adequate clearance for wiring and adjustments.
- Pressure Connection: Connect the pressure sensing line from the system to the control's pressure port. Ensure all connections are leak-tight.
- Electrical Wiring: Wire the control according to the system's electrical schematic. Verify that the power supply matches the control's voltage and current ratings. Ensure proper grounding.
- Initial Adjustment: Set the desired cut-out and differential pressures using the adjustment mechanisms. For models with sight-set calibration, adjustments can be made without removing the cover.
- System Start-up: After installation, carefully re-energize the system and monitor the control's operation to ensure it functions as intended.
5. Operating Instructions
The P70AA-5C Pressure Control operates automatically once properly installed and configured. Its primary function is to monitor system pressure and activate or deactivate connected equipment based on setpoints.
- Pressure Monitoring: The control continuously senses the system pressure through its connected line.
- Setpoint Activation: When the sensed pressure reaches the low pressure cut-out setpoint, the control's switch changes state, typically deactivating the compressor or other equipment to prevent damage from low pressure conditions.
- Differential: The differential setting determines the pressure rise required before the control resets and allows the equipment to restart. This prevents rapid cycling.
- Manual Reset (if applicable): If the manual reset lockout option is present and activated, the control will remain in a locked-out state until manually reset, even if pressure returns to normal. This requires operator intervention to ensure system integrity.
6. Maintenance
The Johnson Controls P70AA-5C Pressure Control is designed for minimal maintenance. Regular inspections are recommended to ensure continued reliable operation.
- Periodic Inspection: Annually inspect the control for any signs of physical damage, corrosion, or loose connections.
- Pressure Line Integrity: Check the pressure sensing line for kinks, leaks, or blockages that could affect accurate pressure readings.
- Electrical Connections: Verify that all electrical terminals are clean and securely fastened.
- Calibration Check: Periodically verify the accuracy of the pressure setpoints against a calibrated pressure gauge. Adjust if necessary.
- Cleaning: Keep the exterior of the control clean and free of dust and debris. Do not use abrasive cleaners or solvents.
7. Troubleshooting
This section provides guidance for common issues that may arise with the P70AA-5C Pressure Control. For complex problems, consult a qualified HVAC technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Control does not activate/deactivate at setpoint. | Incorrect setpoint adjustment; Faulty wiring; Pressure line blockage; Defective control. | Verify setpoints; Check all wiring connections; Clear pressure line; Replace control if defective. |
| System cycles too frequently. | Differential set too narrow; System pressure fluctuations. | Increase differential setting; Investigate system for underlying pressure instability. |
| Control is locked out (manual reset models). | Low pressure condition occurred and activated lockout. | Identify and resolve the low pressure issue; Manually reset the control. |
| Inaccurate pressure readings. | Pressure line leak or blockage; Sensor malfunction. | Check pressure line for integrity; Calibrate or replace control. |
8. Specifications
| Attribute | Detail |
|---|---|
| Model Number | P70AA-5C |
| Brand | Johnson Controls |
| Product Dimensions | 10 x 4 x 2 inches |
| Item Weight | 4 Pounds |
| Manufacturer | Johnson Controls Inc |
| Application | Low pressure cut-out, pump-down, capacity control for commercial refrigeration and A/C. |
| Pressure Range | 20" Hg to 100 psi (specific to P70AA-5C) |
| Compatibility | Most common refrigerants, non-corrosive fluid applications. |
9. Warranty and Support
Specific warranty details for the Johnson Controls P70AA-5C Pressure Control are typically provided at the point of purchase or within the product packaging. For detailed warranty information, please refer to the documentation included with your product or contact Johnson Controls directly.
For technical support, service, or replacement parts, please contact your authorized Johnson Controls distributor or visit the official Johnson Controls website for contact information.