Schneider Electric XB6AV3GB

Schneider Electric XB6AV3GB Round Green LED 120VAC Indicator Manual

Model: XB6AV3GB

Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the Schneider Electric XB6AV3GB Round Green LED 120VAC Indicator. This device is designed for use as a visual status indicator in various electrical control applications.

Safety Information

WARNING: Risk of electric shock. Installation and maintenance should only be performed by qualified personnel. Disconnect all power before working on the device or associated circuitry.

Setup and Installation

The XB6AV3GB LED indicator is designed for panel mounting. Ensure the mounting hole size is appropriate for the indicator's diameter.

  1. Prepare Mounting Location: Select a suitable location on your control panel. Drill or punch a round hole of the correct diameter for the indicator.
  2. Mount the Indicator: Insert the indicator into the prepared hole from the front of the panel. Secure it in place using the provided locking nut or retaining ring on the rear of the panel.
  3. Wiring: Connect the indicator to a 120VAC power source. The indicator typically has two terminals for power connection. Ensure correct polarity if specified (though many AC indicators are non-polar). Refer to the wiring diagram on the device or packaging if available.

Note: This LED indicator is designed for 120VAC. If integrating into a system previously using BA9s incandescent lamps, ensure compatibility or procure necessary adapters for proper fit and function.

Schneider Electric XB6AV3GB Round Green LED Indicator

Image: Schneider Electric XB6AV3GB Round Green LED Indicator. This image shows the front view of the round green LED indicator, typically used for panel mounting.

Operating Instructions

The Schneider Electric XB6AV3GB is a simple indicator device. Once properly installed and wired, it will illuminate green when power is supplied to its terminals, indicating the status of the circuit or equipment it monitors.

No user interaction is required for its operation beyond providing the correct power input.

Maintenance

The XB6AV3GB LED indicator is designed for durability and requires minimal maintenance.

Troubleshooting

ProblemPossible CauseSolution
LED does not light upNo power to the indicatorCheck the power supply to the circuit. Verify circuit breaker or fuse.
LED does not light upIncorrect wiringVerify wiring connections are secure and correct according to the diagram.
LED does not light upFaulty indicator unitReplace the indicator unit.
LED flickers or is dimUnstable power supply or loose connectionCheck power supply stability and tighten all wiring connections.

Specifications

Warranty and Support

For warranty information and technical support, please refer to the official Schneider Electric website or contact your local Schneider Electric representative. Keep your purchase receipt for warranty claims.

Related Documents - XB6AV3GB

Preview Schneider Electric Acti9 A9E1832 Phase Indicating Light - Installation & Technical Guide
Official installation instructions and technical specifications for the Schneider Electric Acti9 A9E1832 3-phase indicating light. Learn about its features, connection, and safety guidelines.
Preview Schneider Electric XVM-B/M/G Instruction Service Manual
Detailed installation and service instructions for the Schneider Electric XVM-B/M/G signaling unit, including safety warnings, assembly steps, connection details, and technical specifications to ensure proper setup and operation.
Preview Schneider Electric RESI9 RCBO End of Life Instructions and Disposal Guide
Comprehensive guide for the end-of-life treatment and disposal of Schneider Electric RESI9 Residual Current Breakers with Overcurrent Protection (RCBOs), including disassembly risks and component information.
Preview Schneider Electric ComPact NS MasterPact NW Product Sheet and Operating Guide
Detailed product sheet for Schneider Electric's ComPact NS MasterPact NW series, covering technical specifications, packaging details, durability compliance (REACH, RoHS), and warranty information. Essential guide for users and integrators.
Preview Schneider Electric Class 9422 Type CMP Cable Operating Mechanisms Installation and Adjustment Guide
This document provides detailed instructions for installing and adjusting Schneider Electric's Class 9422 Type CMP cable operating mechanisms, designed for use with Square D PowerPacT circuit breakers. It includes essential safety warnings, component identification, step-by-step procedures, and technical specifications for proper operation.
Preview Schneider Electric LC1D/LC2D Series Contactors: Technical Specifications and Installation Guide
Comprehensive guide to Schneider Electric's LC1D and LC2D series contactors, covering product specifications, safety warnings, installation procedures, dimensions, wiring, and accessories. Features detailed information for electrical engineers and technicians.