1. Introduction
This manual provides essential instructions for the safe and proper installation, operation, and maintenance of the Schneider Electric GTK03 Equipment Ground Kit. This kit is designed to provide a reliable grounding connection for both copper (Cu) and aluminum (Al) conductors in electrical systems. Please read this manual thoroughly before installation or use.
2. Safety Information
WARNING: Electrical shock hazard. Installation and servicing must be performed by qualified personnel only. Disconnect power before installing or servicing this equipment. Failure to follow these instructions can result in death, serious injury, or equipment damage.
- Always follow local and national electrical codes.
- Ensure all connections are tight and secure to prevent overheating and arcing.
- Verify conductor compatibility (copper or aluminum) with the terminal before connection.
- Wear appropriate personal protective equipment (PPE) during installation.
3. Product Overview
The GTK03 Equipment Ground Kit is a compact, metallic grounding block featuring screw terminals for secure conductor connections and mounting points for panel installation. It is designed to facilitate safe and effective grounding of electrical equipment.

Figure 1: Schneider Electric GTK03 Equipment Ground Kit. This image displays the Schneider Electric GTK03 Equipment Ground Kit. It is a metallic block featuring two main screw terminals designed for connecting copper or aluminum grounding conductors. Additional smaller holes are visible for mounting the kit to a panel or surface.
4. Setup and Installation
- Power Disconnection: Ensure all power to the circuit where the GTK03 will be installed is completely disconnected and locked out.
- Mounting: Select a suitable location on a panel or surface for mounting. Use appropriate fasteners (not included) through the designated mounting holes on the GTK03 to secure it firmly. The mounting type is Panel Mount.
- Conductor Preparation: Strip the insulation from the copper or aluminum grounding conductor to the appropriate length, ensuring no stray strands.
- Conductor Connection: Insert the prepared conductor into one of the screw terminals. Ensure the conductor is fully seated.
- Tightening Connections: Using a suitable tool, tighten the screw terminal to the manufacturer's recommended torque specifications. Over-tightening can damage the terminal or conductor; under-tightening can lead to a poor connection and overheating. Verify the connection is secure.
- Repeat for Additional Conductors: If connecting multiple grounding conductors, repeat steps 3-5 for each conductor. The GTK03 features multiple positions for connections.
- Final Inspection: Visually inspect all connections for proper seating and tightness. Ensure no bare conductors are exposed where they shouldn't be.
5. Operating Instructions
The Schneider Electric GTK03 Equipment Ground Kit is a passive component. Once properly installed and connected, its 'operation' involves continuously providing a low-resistance path for fault currents to safely return to the source, thereby protecting equipment and personnel from electrical hazards. No manual intervention is required for its ongoing function after installation.
6. Maintenance
Regular inspection of the GTK03 and its connections is recommended to ensure continued safety and performance.
- Visual Inspection: Periodically check for any signs of corrosion, discoloration, or physical damage to the kit or its conductors.
- Connection Tightness: Verify that all screw terminal connections remain tight. Loose connections can lead to increased resistance and potential hazards.
- Cleaning: If necessary, gently clean the exterior of the kit with a dry, non-abrasive cloth. Do not use liquids or solvents.
7. Troubleshooting
If issues related to grounding are suspected, consider the following:
- Loose Connections: The most common issue. Re-check and re-tighten all screw terminals to the specified torque.
- Corrosion: Inspect for corrosion on conductors or terminals. Corroded connections can increase resistance. If severe, replacement may be necessary.
- Improper Conductor Sizing: Ensure the connected grounding conductors are appropriately sized for the application according to electrical codes.
- Physical Damage: If the GTK03 unit is physically damaged, it must be replaced immediately.
For persistent issues, consult a qualified electrician.
8. Specifications
| Feature | Specification |
|---|---|
| Model Number | GTK03 |
| Brand | Schneider Electric |
| Item Dimensions (L x W x H) | 1.1 x 0.6 x 0.3 inches |
| Item Weight | 0.64 ounces |
| Connector Type | Screw Terminals |
| Contact Material | Copper, Aluminum |
| Mounting Type | Panel Mount |
| Circuit Type | 1-way |
| International Protection Rating | IP00 |
| Number of Positions | Multiple (for conductors) |
| Control Type | Manual (for installation) |
| UPC | 785901421818 |
9. Warranty Information
The Schneider Electric GTK03 Equipment Ground Kit comes with a 1-year manufacturer's warranty. This warranty covers defects in materials and workmanship under normal use. For warranty claims or detailed terms and conditions, please refer to the official Schneider Electric warranty policy or contact customer support.
10. Support
For technical assistance, product inquiries, or support, please contact Schneider Electric customer service. Visit the official Schneider Electric website for contact details and additional resources.
- Online Resources: www.se.com/us/en/
- Customer Service: Refer to the website for regional contact information.