Vent-Axia 454056

Vent Axia Silhouette 100T Bathroom / Toilet Extractor Fan

Model Number: 454056B

1. Introduction

The Vent Axia Silhouette 100T is a high-performance bathroom and toilet extractor fan designed for efficient ventilation. Its ultra-slim 17mm profile allows for discreet integration with wall surfaces, providing an unobtrusive installation. This model features an integral adjustable electronic overrun timer, allowing the fan to continue operating for a set period after the light switch is turned off, ensuring effective moisture and odor removal.

The fan is suitable for ceiling or panel mounting and can be connected to appropriate ducting for external exhaust. Optional fixing kits are available for wall and window installations.

2. Safety Information

Please read all safety instructions carefully before installation or operation. Failure to comply with these instructions may result in electric shock, fire, or personal injury.

3. Package Contents

Verify that all components are present and undamaged upon opening the package:

4. Features

5. Setup and Installation

Installation of this electrical appliance should only be performed by a qualified electrician.

Vent Axia Silhouette 100T Bathroom Extractor Fan, front view.

Image: Vent Axia Silhouette 100T Bathroom Extractor Fan. This image shows the Vent Axia Silhouette 100T Bathroom Extractor Fan. It is a white, square-shaped fan with a circular grille covering the fan blades. The Vent-Axia logo is visible in blue text at the bottom right of the fan's front panel. A small cylindrical protrusion is visible on the left side, indicating the duct connection.

  1. Preparation: Ensure the power supply is disconnected. Determine the mounting location (ceiling, wall, panel, or window) and ensure there is sufficient space for the fan unit and ducting.
  2. Mounting Hole: Cut an appropriate size hole for the fan body and duct connection. Refer to the fan's dimensions for precise measurements.
  3. Wiring: Connect the electrical wiring according to the wiring diagram provided in the fan's internal instructions. This model features an integral earth. Ensure Live (L), Switched Live (SL), and Neutral (N) connections are correctly made. The Switched Live connection activates the fan and timer.
  4. Ducting: Connect suitable ducting (e.g., 100mm diameter) from the fan's spigot to the external exhaust point. Ensure ducting is as straight and short as possible to maximize airflow.
  5. Secure Fan: Secure the fan unit firmly in place using appropriate fixings for your mounting surface. Ensure the fan is level and stable.
  6. Timer Adjustment: Before replacing the front fascia, adjust the electronic overrun timer to the desired setting (5-30 minutes) using the small adjustment screw/dial located on the fan unit.
  7. Fascia Installation: Carefully attach the ultra-low profile front fascia to the fan unit. Ensure it clicks securely into place.
  8. Power Restoration: Once installation is complete and all connections are secure, restore power to the fan at the consumer unit/fuse box.

6. Operating Instructions

The Vent Axia Silhouette 100T operates automatically when connected to a switched live supply, typically linked to a room's lighting circuit.

7. Maintenance

Regular cleaning and maintenance will ensure optimal performance and longevity of your extractor fan.

8. Troubleshooting

If you experience issues with your Vent Axia Silhouette 100T fan, refer to the table below for common problems and solutions.

ProblemPossible CauseSolution
Fan does not operateNo power supply
Incorrect wiring
Timer set to minimum or faulty
Check circuit breaker/fuse
Verify wiring connections (consult electrician)
Adjust timer setting; if still not working, contact support
Fan is excessively noisyObstruction in fan blades/grille
Loose mounting
Ducting issues (e.g., too restrictive, sharp bends)
Fan motor issue
Disconnect power and check for debris; clean fan
Ensure fan is securely mounted
Inspect ducting for blockages or improper installation
Contact support if noise persists after checking other causes
Poor extraction/airflowBlocked grille or ducting
Fan size inadequate for room volume
Back draught shutter stuck
Clean grille and check ducting for obstructions
Ensure fan capacity matches room requirements
Disconnect power and check back draught shutter for free movement
Timer not working correctlyIncorrect timer setting
Faulty timer component
Adjust timer setting as per instructions
Contact support for potential replacement or repair

9. Specifications

SpecificationValue
ManufacturerVent-Axia
Part Number454056
Product Dimensions6.38 x 6.61 x 4.17 cm
Item Model Number454056
ColourWhite
StyleModern
FinishWhite
Power SourceCorded Electric
Wattage16 watts
Item Package Quantity1
Number of Pieces1
Flow Rate21 Litres Per Second (FID performance)
Air Flow Capacity21 Cubic Feet Per Minute
Sound Level38 dB
Blade Length4 Inches
Speed1 RPM (Single Speed)
Special FeaturesLightweight
Batteries Included?No
Batteries Required?No
Item Weight550 g
Room TypeBathroom
Recommended UsesCeiling

10. Warranty and Support

For warranty information, technical support, or service inquiries regarding your Vent Axia Silhouette 100T fan, please refer to the documentation provided with your purchase or contact Vent-Axia customer service directly. Contact details can typically be found on the manufacturer's official website or on the product packaging.

When contacting support, please have your product model number (454056B) and purchase date readily available.

Related Documents - 454056

Preview Vent-Axia PureAir Sense Bathroom Fan with Odour Sense Technology - Instruction Manual
Comprehensive instruction manual for the Vent-Axia PureAir Sense bathroom fan, detailing installation, functions, technical specifications, maintenance, app connectivity, and warranty. Features Odour Sense Technology and automatic humidity control for optimal bathroom ventilation.
Preview Vent-Axia VA140/150 Range Axial Kitchen Fans: Installation and Wiring Guide
Comprehensive installation and wiring instructions for Vent-Axia VA140/150 range axial kitchen fans, covering models KP, KT, KHP, and KHT. Includes safety guidelines, mounting procedures, wiring diagrams, adjustments, and maintenance.
Preview Vent-Axia Centra Lo-Carbon SELV Extractor Fan Installation and Wiring Instructions
Comprehensive installation and wiring guide for the Vent-Axia Centra Lo-Carbon SELV 100mm continuous extract fan, covering safety, mounting, wiring, and setup for models 443175A, 443176A, 443177A, and 447128A.
Preview Vent-Axia Svara Bathroom Fan: Installation and User Manual
Comprehensive guide for installing and operating the Vent-Axia Svara stylish and versatile bathroom fan, covering electrical connections, safety, maintenance, and app integration.
Preview Vent-Axia Lo-Carbon Response 7 Home Owner Guide: Reduce Condensation and Mould
A comprehensive guide for homeowners on the Vent-Axia Lo-Carbon Response 7 ventilation system, explaining how it prevents condensation and mould, improves air quality, and its low running costs.
Preview Vent-Axia Lo-Carbon Response Extractor Fan: Installation and Wiring Guide
Comprehensive installation and wiring instructions for the Vent-Axia Lo-Carbon Response continuous extract fan range, covering safety, setup, wiring diagrams, and maintenance. Includes product details, accessories, and energy comparison.