Seaflo SFDP1-045-040-41

Seaflo 12 Volt 17 Litre Per Minute Automatic Pressure Water Pump Instruction Manual

Model: SFDP1-045-040-41

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Seaflo 12 Volt 17 Litre Per Minute Automatic Pressure Water Pump, model SFDP1-045-040-41. This pump is designed for reliable water transfer in various applications, featuring an automatic pressure switch, a quiet 4-chamber diaphragm, and a bypass system for smooth, pulsation-free water flow. It is capable of dry running without damage and includes a water filter for optimal performance.

Seaflo 12 Volt 17 Litre Per Minute Automatic Pressure Water Pump

Figure 1.1: Overview of the Seaflo Automatic Pressure Water Pump with included fittings.

2. Safety Information

Please read and understand all safety instructions before installing or operating the pump. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Setup and Installation

3.1. Mounting

Mount the pump in a dry, accessible location. The mounting feet are designed to provide excellent vibration isolation, reducing operational noise. Ensure the pump is securely fastened to a stable surface using appropriate hardware.

Seaflo Water Pump Dimensions Diagram

Figure 3.1: Dimensional drawing of the Seaflo Water Pump. Dimensions are approximately 210mm (L) x 102mm (W) x 98.5mm (H).

3.2. Electrical Connection

Connect the pump to a 12 Volt DC power source. The pump requires a 6 Amp power supply. Ensure correct polarity (red wire to positive, black wire to negative) and use appropriate gauge wiring and fusing for the circuit. All electrical connections should be secure and protected from moisture.

3.3. Plumbing Connection

The pump is supplied with a water filter and fittings for 12 mm hose connections. Install the filter on the inlet side of the pump to prevent debris from entering the pump mechanism. Ensure all hose connections are tight to prevent leaks.

Seaflo Water Pump with Inlet and Outlet Connections

Figure 3.2: View of the pump showing the inlet (with filter) and outlet connections.

4. Operating Instructions

Once properly installed and connected, the Seaflo pump operates automatically based on demand.

  1. Priming: Ensure there is water available at the inlet. Open a faucet in the system to allow air to escape. The pump will begin to draw water and self-prime.
  2. Automatic Operation: The integrated pressure switch will turn the pump on when water pressure drops (e.g., when a faucet is opened) and turn it off when the pressure is restored (e.g., when the faucet is closed).
  3. Smooth Flow: The 4-chamber diaphragm and bypass system work together to provide a consistent, pulsation-free water flow, enhancing user comfort and system longevity.
  4. Quiet Performance: The pump is designed for ultra-quiet operation, minimizing disturbance.

5. Maintenance

Regular maintenance ensures the longevity and efficient operation of your Seaflo pump.

6. Troubleshooting

ProblemPossible CauseSolution
Pump does not runNo power; Blown fuse; Loose wiringCheck power supply, fuse, and all electrical connections.
Low flow or no pressureClogged inlet filter; Air in system; Kinked hose; Low voltageClean filter; Bleed air from system; Check hoses for obstructions; Verify 12V supply.
Pump runs continuouslyLeak in plumbing; Faulty pressure switchCheck all connections for leaks; Inspect or replace pressure switch.
Excessive noise/vibrationLoose mounting; Air in system; Debris in pumpSecure pump mounting; Bleed air; Inspect pump for foreign objects.

7. Specifications

FeatureDetail
Model NumberSFDP1-045-040-41
BrandSeaflo
Voltage12 Volts
Power Consumption6 Amps (Max 15.0A)
Maximum Flow Rate17 Litres per minute (4.5 GPM)
Pressure Setting40 PSI / 2.8 Bar
Hose Connection12 mm
Item Weight2.7 Kilograms
Product Dimensions (L x W x H)210 x 102 x 98.5 mm (approximate, based on technical drawing)
MaterialAluminium (housing)
FeaturesAutomatic pressure switch, 4-chamber diaphragm, bypass system, dry run capability, integrated water filter

8. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or contact your authorized Seaflo dealer. Keep your purchase receipt as proof of purchase.

Related Documents - SFDP1-045-040-41

Preview SEAFLO 3.0/5.5 GPM Pump with Integrated Accumulator Tank Installation Manual
Installation manual for SEAFLO 3.0/5.5 GPM pumps with integrated accumulator tanks. Covers features, specifications, operation, safety, dimensions, and repair kits for models SFWSK1/SFWSK2.
Preview SEAFLO Electric Flush Pump Installation Manual
Installation manual for SEAFLO Electric Flush Pump conversion kits (SFMTP1-02, SFMTP2-02), providing instructions for installation, operation, maintenance, and troubleshooting of marine toilet systems.
Preview SEAFLO SFCBS-300-202 Single Circuit ON/OFF Battery Disconnect Switch Manual
Comprehensive manual for the SEAFLO SFCBS-300-202 Single Circuit ON/OFF Battery Disconnect Switch, detailing features, specifications, regulatory compliance, installation, and operation for marine electrical systems.
Preview SEAFLO 02 Float Switch Instruction Manual - Installation and Operation Guide
Comprehensive instruction manual for the SEAFLO 02 Float Switch (Model SFBS-18-02). Covers installation, wiring, testing, and operating principles for marine bilge pump systems. Includes safety precautions and specifications.
Preview SEAFLO Ultrasonic Defense System: Installation and Operation Guide
Comprehensive guide to installing and operating the SEAFLO Ultrasonic Defense System for marine antifouling, detailing its features, benefits, technical specifications, and installation procedures.
Preview Modification d'un WC Chimique en WC à Broyeur Marin
Guide détaillé pour transformer un WC chimique en système WC à broyeur pour bateaux, incluant l'amélioration de l'alimentation en eau et l'installation d'une pompe Seaflo. Améliorez votre sanitation marine avec ces modifications DIY.