Introduction
The Makita PF1010 is a lightweight and compact submersible pump designed for efficient drainage of water from various sources such as tanks, swimming pools, and water basins. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Makita PF1010 water pump. Please read this manual thoroughly before use.
Safety Instructions
Always adhere to the following safety guidelines to prevent injury and damage to the pump:
- Ensure the power source matches the pump's requirements.
- Do not operate the pump with damaged cords or plugs.
- Keep hands and feet clear of the pump's intake during operation.
- The pump is designed for water only; do not use it for flammable or corrosive liquids.
- Always disconnect power before performing any maintenance or cleaning.
- Do not lift the pump by its power cord.
Package Contents
Verify that all items are present upon unboxing:
- Makita PF1010 Submersible Water Pump (1 unit)
- User Manual
Product Overview

Image: The Makita PF1010 submersible water pump, featuring a black base and a teal upper housing with the Makita logo. A black power cord and float switch are visible on the left side, and a hose connection elbow is on the right.
The Makita PF1010 is a robust submersible pump designed for efficient water transfer. Key features include:
- Capacity: 14,400 Liters Per Hour (Maximum Flow Rate)
- Maximum Lifting Height: 10 Meters
- Minimum water level for operation: 40 mm (approximate residual water level)
- Handles particles up to 35 mm
- Durable Acrylonitrile Butadiene Styrene (ABS) casing
- Corded Electric power source
- Product Dimensions (L x W x H): 6.3" x 6.3" x 14.96"
- Item Weight: 14.55 Pounds
Setup
- Unpacking: Carefully remove the pump from its packaging. Inspect for any damage.
- Hose Connection: Attach a suitable discharge hose (38.1 mm connection) to the pump's outlet. Ensure a secure, leak-free connection.
- Placement: Position the pump on a stable, flat surface in the water source. Ensure it is fully submerged if required for operation, or placed at the desired water level.
- Float Switch Adjustment: Adjust the float switch cable length to control the automatic on/off levels of the pump. A longer cable allows the pump to start at a higher water level and stop at a lower level.
- Power Connection: Connect the pump to a grounded electrical outlet. Ensure the voltage matches the pump's requirements.
Operating Instructions
- Automatic Operation: Once connected to power and submerged, the pump will automatically start when the water level rises and activates the float switch. It will stop when the water level drops and the float switch deactivates.
- Manual Operation: Refer to specific product markings or additional documentation if your model supports manual override of the float switch.
- Monitoring: Periodically check the pump's operation and the discharge flow to ensure efficient drainage.
- Particle Handling: The pump is capable of handling particles up to 35 mm. Avoid pumping larger debris to prevent clogging or damage.
Maintenance
Regular maintenance ensures the longevity and optimal performance of your pump.
- Cleaning: Periodically clean the pump's intake screen to remove any accumulated debris. Disconnect power before cleaning.
- Inspection: Regularly inspect the power cord and plug for any signs of damage. Check hose connections for leaks.
- Storage: If storing the pump for an extended period, clean it thoroughly, drain all water, and store in a dry, frost-free location.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; Float switch not activated; Clogged intake | Check power supply; Ensure water level is high enough to activate float switch; Clean intake screen |
| Low flow rate | Partially clogged intake/hose; Kinked hose; Insufficient water level | Clean intake/hose; Straighten hose; Ensure adequate water level |
| Pump runs continuously | Float switch stuck in 'on' position; Continuous water inflow | Check float switch for obstructions; Address continuous water source |
Specifications
- Brand: Makita
- Model: PF1010
- Power Source: Corded Electric
- Maximum Flow Rate: 14,400 Liters Per Hour
- Maximum Lifting Height: 10 Meters
- Particle Handling: Up to 35 mm
- Product Dimensions (L x W x H): 6.3" x 6.3" x 14.96"
- Item Weight: 14.55 Pounds
- Material: Acrylonitrile Butadiene Styrene (ABS)
- Color: Black
- Hose Connection: 38.1 mm
Warranty and Support
Makita products are manufactured to high standards and undergo rigorous quality control.
For warranty information, technical support, or service inquiries, please contact Makita customer service or visit the official Makita website. Keep your purchase receipt as proof of purchase.
EU Spare Part Availability Duration: 1 Year.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.