1. Introduction
The VALCOM V-2006A is a sophisticated 6-zone one-way page control unit designed to manage paging communications across multiple areas. This unit facilitates paging to six individual zones or an all-call broadcast, ensuring efficient communication within a facility. It integrates a built-in tone generator for various notification purposes and includes an emergency page override feature for critical announcements.
2. Setup
2.1. Installation
Mount the V-2006A unit in a secure, accessible location, ensuring adequate ventilation. Avoid areas with excessive heat, moisture, or electromagnetic interference.
2.2. Wiring Connections
Connect the V-2006A to your telephone system via a page port. Supported access methods include:
- PBX Loop Start or Ground-Start Trunk Port
- Electronic or 1A2 Line Key (requires a line card)
- Dedicated Single Line Phone Set
Connect speaker outputs to the respective zones. Ensure proper impedance matching for optimal audio quality. The unit also supports a background music input.
2.3. Power Connection
Connect the unit to a suitable power source as specified in the 'Specifications' section. The V-2006A includes a battery back-up input (VPB-260) for continuous operation during power outages. Ensure the battery backup unit is connected correctly if utilized.
3. Operating Instructions
3.1. Initiating a Page
To initiate a page, access the V-2006A through the configured telephone system port. Dial the appropriate code for the desired zone (1-6) or the all-call code. Speak clearly into the telephone handset or microphone.
3.2. Zone Programming
Features are programmable per zone, allowing customization of paging behavior. Refer to the detailed programming guide (if provided separately) for specific instructions on configuring individual zones and group zones.
3.3. Tone Generation
The built-in tone generator can be activated to provide various notifications, such as break times, night rings, or doorbells. Consult the system's programming guide for activating and customizing these tones.
3.4. Emergency Page Override
The V-2006A features an emergency page override function for priority announcements. This allows critical messages to supersede ongoing communications. Activate this feature by dialing the designated emergency override code.
3.5. Background Music
The unit accepts pulse dial and tone dial background music input. When a page is initiated in a specific zone, the background music in that zone will automatically mute, ensuring the page is clearly heard.
4. Maintenance
The VALCOM V-2006A is designed for reliable operation with minimal maintenance. Keep the unit clean and free from dust. Ensure all connections are secure. Do not attempt to service the unit beyond basic cleaning; refer all repairs to qualified personnel.
5. Troubleshooting
If you experience issues with your V-2006A unit, consider the following common troubleshooting steps:
- No Power: Check the power connection and ensure the power supply is functioning correctly. Verify the battery backup (if installed) is charged.
- No Paging Audio: Confirm that the telephone system connection is active and correctly configured. Check speaker wiring and ensure speakers are operational.
- Distorted Audio: Verify input and output impedance settings. Check for loose connections or damaged cables.
- Music Not Muting: Ensure the background music input is correctly wired and the automatic mute feature is enabled in the zone programming.
For persistent issues, contact VALCOM technical support.
6. Specifications
| Feature | Specification |
|---|---|
| Model Number | V-2006A |
| Product Dimensions (H x W x D) | 3 x 13 x 11 inches (7.62 cm x 33.02 cm x 27.94 cm) |
| Item Weight | 9.5 pounds (4.31 kg) |
| Input Impedance | 600 ohm |
| Music Source Impedance | 4 to 600 ohm |
| Music Input Level | -10 dBm nominal |
| DC Output | -24 Vdc @ 1.5A |
| Power Requirements | 120 Vac/2A or 230 Vac/.1A (UL Listed) |
| Access | Page Port on Selected Telephone Systems, PBX Loop Start or Ground-Start Trunk Port, Electronic or 1A2 Line Key, Dedicated Single Line Phone Set |
| Battery Back-Up Input | Yes (VPB-260 compatible) |