Liebert PD2-106

Download PDF
Contents

Liebert PD2-106 8-Outlets PDU User Manual

Model: PD2-106

1. Product Overview

The Liebert PD2-106 is an 8-outlet Power Distribution Unit (PDU) designed to provide reliable power distribution for various equipment. It features a combination of NEMA L6-20R and NEMA L5-20R output receptacles, making it versatile for different power requirements. The unit is hardwire terminal block 3W + G for input, ensuring a secure and stable power connection.

Liebert PD2-106 8-Outlets PDU with multiple power cables extending from the unit.

Figure 1: Front view of the Liebert PD2-106 PDU, showing the main unit with eight power cables connected to its outlets. The unit is dark gray with visible mounting points and various power receptacles.

2. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your PD2-106 PDU. This unit is designed for hardwire installation.

2.1 Unpacking and Inspection

  • Carefully remove the PDU from its packaging.
  • Inspect the unit for any signs of shipping damage. If damage is found, contact your supplier immediately.
  • Verify that all components listed in the packing list are present.

2.2 Mounting the PDU

The PD2-106 PDU can be mounted in a suitable rack or enclosure. Ensure the mounting surface is stable and can support the weight of the PDU and connected equipment.

  • Identify appropriate mounting points on your rack or wall.
  • Secure the PDU using appropriate mounting hardware (not included). Ensure it is level and firmly attached.

2.3 Electrical Connection

The input connection for the PD2-106 is a hardwire terminal block (3W + G). All electrical work should be performed by a qualified electrician in accordance with local and national electrical codes.

  • Ensure the power source is disconnected before making any connections.
  • Connect the input power cables to the terminal block as per the wiring diagram provided with the unit (refer to manufacturer's specific wiring instructions).
  • Connect your equipment to the output receptacles: 4 x NEMA L5-20R and 4 x NEMA L6-20R. Ensure that the total load does not exceed the PDU's maximum capacity.
  • Verify all connections are secure before restoring power.

3. Operating Instructions

The Liebert PD2-106 PDU is designed for straightforward operation once installed.

3.1 Powering On

  1. After all electrical connections are made and verified, restore power to the hardwire input.
  2. The PDU will distribute power to all connected devices through its output receptacles.

3.2 Connecting Devices

  • Plug your NEMA L5-20P and NEMA L6-20P compatible devices directly into the corresponding outlets on the PDU.
  • Ensure that the power requirements of your connected devices do not exceed the individual outlet's rating or the PDU's overall capacity.

3.3 Powering Off

To power off the PDU and connected devices, disconnect the main input power source to the hardwire terminal block.

4. Maintenance

Regular maintenance helps ensure the longevity and reliable performance of your PD2-106 PDU.

  • Periodic Inspection: Regularly inspect the PDU and all connected cables for any signs of wear, damage, or loose connections.
  • Cleaning: Keep the PDU clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners or solvents. Ensure the unit is powered off before cleaning.
  • Ventilation: Ensure that the PDU's ventilation openings are not blocked to prevent overheating.
  • Load Management: Periodically review the power consumption of connected devices to ensure the total load remains within the PDU's rated capacity.

5. Troubleshooting

This section provides solutions to common issues you might encounter with your PD2-106 PDU.

ProblemPossible CauseSolution
No power output from PDU.Input power disconnected or circuit breaker tripped.Check the main power source to the PDU. Reset any tripped circuit breakers. Ensure hardwire connections are secure.
Specific outlet has no power.Device connected to outlet is faulty or drawing too much power.Test the device on another power source. Reduce the load on the outlet if overloaded.
PDU feels hot.Overloaded PDU or inadequate ventilation.Reduce the total load connected to the PDU. Ensure proper airflow around the unit and clear any obstructions from ventilation openings.
Loose connections.Vibration or improper installation.With power disconnected, inspect and tighten all hardwire and outlet connections.

If the problem persists after attempting these solutions, contact a qualified technician or the manufacturer's support.

6. Specifications

FeatureDetail
Product TypePDU (Power Distribution Unit)
Model NumberPD2-106
Input ReceptaclesHardwire Terminal Block 3W + G
Output Receptacles4 x NEMA L5-20R, 4 x NEMA L6-20R
Product Dimensions (L x W x H)21 x 12 x 5 inches
Item Weight12 pounds
Wattage1000 watts
ManufacturerLiebert - Ep1
UPC813829010514, 132017613475

7. Warranty and Support

Specific warranty terms and conditions for the Liebert PD2-106 PDU are provided by the manufacturer. Please refer to the documentation included with your purchase or visit the official Liebert website for detailed warranty information and customer support contacts.

For technical assistance, service, or to inquire about replacement parts, please contact Liebert customer support directly. Keep your product model number (PD2-106) and serial number (if applicable) ready when contacting support.

© 2024 Liebert. All rights reserved. Information subject to change without notice.