Kendal Lighting AC18250-WH

Kendal Lighting AC18250-WH The Novo Ceiling Fan Instruction Manual

Model: AC18250-WH | Brand: Kendal Lighting

Product Overview

The Kendal Lighting AC18250-WH The Novo Ceiling Fan is designed to provide efficient air circulation and integrated lighting for your living space. This model features a white finish, four white blades with a 50-inch span, and an integrated 3-tier light kit. It comes with a full-function remote control for convenient operation.

Kendal Lighting AC18250-WH The Novo Ceiling Fan in white

Image: The Novo Ceiling Fan, showcasing its white finish, four blades, and integrated light kit.

Setup and Installation

Proper installation is crucial for the safe and efficient operation of your ceiling fan. It is recommended that installation be performed by a qualified electrician.

Components Checklist:

Installation Steps (General):

  1. Safety First: Ensure power is disconnected at the circuit breaker before beginning installation.
  2. Mounting Bracket: Securely attach the mounting bracket to a ceiling joist or an approved fan brace.
  3. Wiring: Connect the fan's electrical wires to the household wiring according to local electrical codes. Ensure the remote receiver is properly wired.
  4. Assemble Fan: Attach the fan motor assembly to the mounting bracket.
  5. Install Blades: Securely attach the four fan blades to the motor housing.
  6. Install Light Kit: Connect and secure the integrated 3-tier light kit to the fan motor assembly. Install the provided G9 light bulbs.
  7. Test: Restore power and test the fan and light functions using the remote control.

Operating Instructions

Your Novo Ceiling Fan comes with a full-function remote control for convenient operation of both the fan and the integrated light kit.

Remote Control Functions:

Ensure the remote control has fresh batteries for optimal performance.

Maintenance

Regular maintenance helps ensure the longevity and optimal performance of your ceiling fan.

Cleaning:

Light Bulb Replacement:

The integrated light kit uses G9 75w T4 120v Halogen bulbs. When replacing, ensure the power is off at the circuit breaker and allow the bulb to cool before handling.

  1. Turn off power to the fan at the circuit breaker.
  2. Carefully remove the old G9 bulb from its socket.
  3. Insert the new G9 bulb firmly into the socket.
  4. Restore power and test the light.

Troubleshooting

If you experience issues with your Novo Ceiling Fan, refer to the following common troubleshooting steps:

ProblemPossible CauseSolution
Fan does not operate.No power; loose wiring; remote control issues.Check circuit breaker. Verify all wire connections. Replace remote batteries. Ensure remote receiver is properly installed.
Light does not turn on.Burned out bulb; loose wiring; light switch off.Replace G9 bulb. Check light kit wiring. Ensure light function on remote is activated.
Fan wobbles.Loose blades; unbalanced blades; improper mounting.Ensure all blade screws are tight. Use a balancing kit (not included) if necessary. Verify mounting bracket is secure.
Remote control not working.Dead batteries; remote not paired.Replace batteries. Refer to remote pairing instructions (if applicable, usually in a separate remote manual).

Specifications

FeatureDetail
Model NumberAC18250-WH
BrandKendal Lighting
FinishWhite
Fan Blade ColorWhite
Number of Blades4
Blade Span50 inches
Blade Pitch14 degrees
Light KitIntegrated 3-tier light kit
Light Bulb Type(1) 75w T4 G9 120v Halogen (bulb included with 1 extra)
Motor Size153 x 22mm
Control TypeFull function remote control
Voltage120 Volts

Warranty Information

Kendal Lighting products are manufactured to high-quality standards. This product is covered by the manufacturer's limited warranty. Please refer to the warranty card included with your purchase or visit the official Kendal Lighting website for detailed warranty terms and conditions. Keep your proof of purchase for warranty claims.

Customer Support

For technical assistance, replacement parts, or any questions regarding your Kendal Lighting AC18250-WH The Novo Ceiling Fan, please contact Kendal Lighting customer support. Contact information can typically be found on the manufacturer's website or in the packaging materials.

Note: Always ensure power is disconnected before performing any maintenance or troubleshooting steps.

Related Documents - AC18250-WH

Preview Kendal AC-31360 Ceiling Fan Installation and Operation Manual
Comprehensive guide for installing, operating, and maintaining the Kendal AC-31360 ceiling fan, including safety precautions, troubleshooting, and remote control functions.
Preview Kendal AC31924-BLK Ceiling Fan Installation Instructions
Comprehensive installation, operation, and maintenance guide for the Kendal AC31924-BLK ceiling fan, including safety precautions and troubleshooting tips.
Preview Kendal Lighting PF269-3L: Installation Instructions and Product Overview
Detailed installation guide and safety instructions for the Kendal Lighting PF269-3L ceiling light fixture. Learn about its 3CCT selectable feature and dimmer compatibility.
Preview Kendal Lighting PF271-8LPA Installation Guide
Comprehensive installation guide for the Kendal Lighting PF271-8LPA fixture, including safety instructions, parts list, and step-by-step assembly instructions.
Preview Kendal Lighting TA014-36-ORB Installation and Assembly Guide
Detailed instructions and parts diagram for assembling and installing the Kendal Lighting TA014-36-ORB light fixture, including mounting to an outlet box or track.
Preview Kendal Lighting AC-30842 & AC-30852 Ceiling Fan Installation and Operation Manual
This manual provides detailed instructions for installing, operating, and maintaining Kendal Lighting AC-30842 and AC-30852 ceiling fans. It includes safety warnings, assembly steps, wiring diagrams, remote control usage, troubleshooting tips, and care instructions.