1. Introduction
This manual provides essential information for the installation, operation, and maintenance of the ADTRAN Total Access 912 (Model 4212912L1) IP Router. The Total Access 912 is designed to provide integrated access for voice and data services, featuring a T1 network interface, multiple FXS ports, and robust IP routing capabilities.
2. Product Overview
The ADTRAN Total Access 912 is a versatile IP router offering a comprehensive set of features for converged voice and data networks. Key functionalities include:
- T1 Network Interface: For primary rate digital access.
- 12 FXS Ports: Supporting analog telephone connections.
- DSX-1 Port: For T1 circuit connectivity.
- 10/100 BaseT Ethernet: For local area network connectivity.
- IP Router: Featuring OSPF, BGP, RIP V1/V2, Static routes, and 802.1d Bridging.
- VoIP Support: Includes G.168 Echo Cancellation and support for G.711 and G.729a CODECs, compatible with SIP applications.
- Security Features: Integrated stateful inspection firewall.
- Management: Command Line Interface (CLI), SNMP, Telnet, Craft/Console port, TFTP support.

Figure 1: Front view of the ADTRAN Total Access 912 (4212912L1) IP Router. The device is a rectangular unit with a light gray top casing featuring ventilation slots. A dark blue band runs across the front, below which are several indicator lights. The ADTRAN logo is visible on the left side of the blue band.
3. Setup
3.1 Physical Installation
- Placement: Position the router in a well-ventilated area, away from direct sunlight and heat sources. Ensure adequate space for cable connections.
- Power Connection: Connect the provided power adapter to the router's power input and then to a suitable electrical outlet.
- T1 Network Connection: Connect the T1 line from your service provider to the designated T1 network interface port on the router.
- Ethernet Connection: Connect your local network devices (e.g., switches, computers) to the 10/100 BaseT Ethernet port(s) using standard Ethernet cables.
- FXS Port Connections: Connect analog telephones or fax machines to the FXS ports as required.
- Console Connection (Optional): For initial configuration or troubleshooting, connect a serial cable from your computer's serial port to the router's Craft/Console port.
3.2 Initial Configuration
Upon powering on, the router will perform a self-test. Initial configuration typically involves accessing the device via the console port or a default IP address on the Ethernet interface. Refer to the ADTRAN documentation for specific default IP addresses and login credentials.
- Access the Command Line Interface (CLI) via the console port or Telnet/SSH.
- Configure basic network parameters such as IP addresses, subnet masks, and default gateways.
- Set up T1 interface parameters according to your service provider's specifications.
- Configure VoIP settings, including SIP server details and FXS port assignments.
4. Operating Instructions
4.1 Basic Operation
Once configured, the Total Access 912 operates autonomously. Monitor the front panel LED indicators for status information:
- Power LED: Indicates power status.
- System Status LED: Provides general operational status.
- T1/WAN LEDs: Indicate T1 line activity and status.
- Ethernet Link/Activity LEDs: Show link status and data transmission on Ethernet ports.
- FXS Port LEDs: Indicate the status of connected analog devices.
4.2 Advanced Features
The router supports various advanced configurations:
- Routing Protocols: Configure OSPF, BGP, or RIP for dynamic routing within your network.
- VoIP Services: Manage SIP trunking, dial plans, and CODEC preferences for voice calls.
- Firewall Rules: Implement security policies using the stateful inspection firewall to protect your network.
- Quality of Service (QoS): Prioritize voice and critical data traffic to ensure optimal performance.
5. Maintenance
5.1 Firmware Updates
Regularly check the ADTRAN support website for the latest firmware versions. Firmware updates can provide new features, performance enhancements, and security patches. Follow the manufacturer's instructions carefully when performing updates to avoid service interruption.
5.2 Configuration Backup
Periodically back up your router's configuration to an external storage device. This allows for quick restoration of settings in case of a device failure or accidental configuration changes.
6. Troubleshooting
This section addresses common issues you might encounter with the ADTRAN Total Access 912.
| Issue | Possible Cause | Solution |
|---|---|---|
| No Power | Power cable disconnected, power outlet fault. | Verify power cable connection. Test power outlet with another device. |
| No T1 Link | T1 cable issue, service provider problem, incorrect configuration. | Check T1 cable. Contact service provider. Verify T1 interface configuration. |
| No Ethernet Connectivity | Ethernet cable fault, incorrect IP settings, port disabled. | Check Ethernet cable. Verify device IP configuration. Ensure router port is enabled. |
| Voice Call Issues | Incorrect VoIP configuration, network congestion, FXS port fault. | Review SIP and FXS port configurations. Check network bandwidth. Test with another analog phone. |
| Cannot Access Router Management | Incorrect IP address, firewall blocking access, wrong credentials. | Verify management IP. Check local firewall settings. Use correct username/password. |
7. Specifications
| Feature | Detail |
|---|---|
| Brand | ADTRAN |
| Model Number | 4212912L1 |
| Connectivity Technology | Ethernet |
| WAN Interface | T1 network interface |
| Voice Ports | 12 FXS ports |
| Digital Cross-Connect | DSX-1 port |
| LAN Port Bandwidth | 10/100 megabits per second |
| VoIP Codecs | G.711, G.729a |
| Echo Cancellation | G.168 Echo Cancellation |
| Routing Protocols | OSPF, BGP, RIP V1 and V2, Static routes |
| Bridging | 802.1d Bridging (all protocols) |
| WAN Protocols | Frame Relay, PPP |
| Security | Stateful inspection firewall |
| Management | CLI, SNMP, Telnet, Craft/Console port, TFTP support |
| UPC | 376864074571 |
8. Safety Information
- Ensure the device is installed in a dry, well-ventilated environment.
- Do not block ventilation openings.
- Use only the power adapter supplied with the device.
- Avoid exposing the device to extreme temperatures or humidity.
- Do not attempt to open or repair the device yourself. Refer to qualified service personnel.
9. Warranty and Support
Warranty information for the ADTRAN Total Access 912 (4212912L1) is typically provided at the point of purchase or included with the product packaging. For detailed warranty terms and conditions, please refer to the documentation accompanying your device or visit the official ADTRAN website.
For technical support, product documentation, and software downloads, please visit the ADTRAN support portal or contact ADTRAN customer service directly. Ensure you have your product model number (4212912L1) and any relevant purchase details available when seeking support.