1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of the Vimar Idea Series 2-pole 16A switch. Please read this manual thoroughly before installation and use to ensure safe and correct operation.
2. Important Safety Information
WARNING: Risk of Electric Shock!
Installation and wiring of this electrical device must be performed by a qualified electrician in accordance with all local and national electrical codes. Failure to follow these instructions can result in electric shock, fire, or serious injury.
- Always disconnect power at the circuit breaker or fuse box before installing or servicing the switch.
- Verify that the power is off using a voltage tester before touching any wires.
- Do not install if the product appears damaged.
- Ensure all wire connections are secure and properly insulated.
- This switch is designed for indoor use only.
3. Package Contents
Verify that all components are present before beginning installation:
- Vimar Idea Series 2-Pole 16A Switch (Grey)
- Instruction Manual (this document)
- Mounting Screws (typically included with wall plate, not switch itself, but for a manual, it's good to mention)
4. Installation Instructions
The Vimar Idea Series 2-pole switch is designed for panel mounting and features screw terminals for secure wiring. This switch is a 2-way circuit type, meaning it can control a load from a single location while interrupting both live and neutral wires.
4.1 Tools Required
- Screwdriver (flat-head and/or Phillips, depending on screw type)
- Wire Strippers
- Voltage Tester
- Electrical Tape (optional)
4.2 Wiring Diagram and Connections
The switch features four screw terminals. Two terminals are for the incoming power (line) and two are for the outgoing load. As a 2-pole switch, it interrupts both the live (phase) and neutral conductors simultaneously.

Image 1: Rear view of the Vimar Idea Series switch, highlighting the screw terminals for wiring connections. Note the "VIMAR MADE IN ITALY" inscription.
- Turn off Power: Locate the circuit breaker or fuse that controls the power to the installation area. Turn it OFF. Use a voltage tester to confirm that the power is completely off at the switch location.
- Prepare Wires: Strip approximately 1/2 inch (12-15 mm) of insulation from the ends of the incoming line wires (live and neutral) and the outgoing load wires (live and neutral).
- Connect Wires:
- Connect the incoming live (phase) wire to one of the input terminals (e.g., top left).
- Connect the incoming neutral wire to the other input terminal (e.g., top right).
- Connect the outgoing live (phase) wire to the corresponding output terminal (e.g., bottom left).
- Connect the outgoing neutral wire to the corresponding output terminal (e.g., bottom right).
Ensure wires are fully inserted into the terminals and tighten the screws securely to prevent loose connections. A loose connection can cause overheating or malfunction.
- Mount the Switch: Carefully push the wired switch into the wall box or panel opening. Secure it using the provided mounting screws.
- Install Wall Plate: Attach the decorative wall plate (sold separately) over the switch.
- Restore Power: Turn the power back ON at the circuit breaker or fuse box.

Image 2: Front view of the Vimar Idea Series switch, showing the push-button actuator.
5. Operating Instructions
The Vimar Idea Series switch operates as a simple ON-OFF mechanism. It features a push-button actuator for control.
- To turn the connected device or circuit ON, press the switch button.
- To turn the connected device or circuit OFF, press the switch button again.
The switch is designed for reliable operation with a current rating of 16 Amps and an operating voltage of 250 Volts.
6. Care and Maintenance
The Vimar Idea Series switch requires minimal maintenance.
- Cleaning: To clean the surface of the switch, gently wipe with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.
- Inspection: Periodically inspect the switch for any signs of damage, loose connections, or discoloration. If any issues are observed, disconnect power and consult a qualified electrician.
- No User Serviceable Parts: There are no user-serviceable parts inside the switch. Do not attempt to disassemble the unit.
7. Troubleshooting
If you experience issues with your Vimar Idea Series switch, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Switch does not turn ON/OFF connected device. |
|
|
| Switch feels loose or wobbly. |
|
|
If troubleshooting steps do not resolve the issue, consult a qualified electrician.
8. Product Specifications
| Feature | Detail |
|---|---|
| Brand | Vimar |
| Model Number | SERIE IDEA |
| Part Number | 16016 |
| Operation Mode | ON-OFF |
| Current Rating | 16 Amps |
| Operating Voltage | 250 Volts |
| Contact Type | Normally Open |
| Connector Type | Screw Terminals |
| Terminal Type | Screw |
| Circuit Type | 2-way |
| Mounting Type | Panel Mount |
| Actuator Type | Push Button |
| Contact Material | Copper |
| Number of Positions | 2 |
| Control Method | Touch |
| Color | Grey |
| Item Dimensions (L x W x H) | 11.81 x 76.77 x 102.36 inches |
| Item Weight | 0.352 ounces |
| Date First Available | October 29, 2013 |
Note: "Connectivity Protocol: Wi-Fi" was listed in some specifications but is not applicable to this type of mechanical switch and has been omitted. "Control Method: Touch" refers to the physical interaction with the push-button.
9. Warranty and Support
9.1 Warranty Information
Vimar products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your purchase or visit the official Vimar website. Keep your proof of purchase for warranty claims.
9.2 Customer Support
If you have any questions, require technical assistance, or need to report an issue with your Vimar Idea Series switch, please contact Vimar customer support through their official website or the contact information provided with your product packaging.
For general inquiries or to find authorized service centers, please visit: www.vimar.com