Quadra-Fire Mt. Vernon AE Feed Motor (SRV7000-313) Instruction Manual

Model: SRV7000-313

Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your Quadra-Fire Mt. Vernon AE Feed Motor, model SRV7000-313. This component is a direct replacement for specific Quadra-Fire pellet stoves and inserts. Please read these instructions thoroughly before proceeding with installation or any maintenance to ensure safe and efficient operation.

Important Safety Information

  • Disconnect Power: Always ensure the pellet stove is completely disconnected from its power source before attempting any installation, maintenance, or repair. Failure to do so can result in electric shock or serious injury.
  • Allow Cooling: Ensure the stove has completely cooled down before working on any internal components to prevent burns.
  • Wear Protective Gear: Wear appropriate personal protective equipment, such as gloves and eye protection, during installation and maintenance.
  • Qualified Technician: If you are unsure about any step, it is recommended to consult a qualified service technician.
  • Use Genuine Parts: Only use genuine Quadra-Fire replacement parts to ensure compatibility and maintain product warranty.

Package Contents

Verify that all items are present and undamaged upon opening the package:

  • 1 x Quadra-Fire Mt. Vernon AE Feed Motor (SRV7000-313)

Note: Additional tools required for installation (e.g., screwdrivers, wrenches) are not included.

Installation Guide

Applicable Models

This feed motor is compatible with the following Quadra-Fire units:

  • Mt. Vernon AE Pellet Stove
  • Mt. Vernon AE Insert
  • Edge60 Pellet Fireplace
  • Cab50 Pellet Stove

Important: This feed motor is not compatible with Mt. Vernon Original Pellet Stoves. It is designed for AE models only.

Step-by-Step Installation

Follow these steps to replace the feed motor:

  1. Prepare the Stove: Ensure the pellet stove is completely cool and disconnected from all power sources.
  2. Access the Motor: Locate the access panel for the feed motor. This typically involves opening the front door or a side panel of the stove. Refer to your specific stove model's manual for exact panel removal instructions.
  3. Disconnect Wiring: Carefully disconnect the electrical wires connected to the existing feed motor. Note the position of each wire for correct reinstallation.
  4. Remove Old Motor: Unscrew and remove the mounting bolts or fasteners securing the old feed motor. Carefully extract the motor from its position.
  5. Install New Motor: Position the new SRV7000-313 feed motor in the same location as the old one. Secure it with the mounting bolts or fasteners.
Quadra-Fire Mt. Vernon AE Feed Motor (SRV7000-313)

Image: The Quadra-Fire Mt. Vernon AE Feed Motor (SRV7000-313). This is the replacement part you will be installing.

  1. Reconnect Wiring: Reconnect the electrical wires to the new feed motor, ensuring they are securely attached to their correct terminals.
  2. Reassemble: Replace any removed panels or doors, ensuring all fasteners are tightened.
  3. Test Operation: Reconnect power to the stove and test its operation according to your stove's user manual.

Video: This video demonstrates the process of accessing internal components and disconnecting wiring within a Quadra-Fire stove, specifically for an igniter replacement. The general steps for accessing the motor compartment and handling electrical connections are similar for the feed motor replacement.

Operating Instructions

The Quadra-Fire Mt. Vernon AE Feed Motor is an internal component of your pellet stove. Its operation is controlled by the stove's main control board. Once installed correctly, the motor will function automatically as part of the stove's normal operating cycle to feed pellets into the burn pot. Refer to your specific Quadra-Fire pellet stove or insert user manual for detailed operating instructions of the appliance itself.

Maintenance

Regular maintenance helps ensure the longevity and efficient performance of your feed motor and pellet stove:

  • Regular Cleaning: Periodically inspect the auger and feed motor area for any accumulation of pellet dust or debris. Clean as necessary to prevent blockages and strain on the motor.
  • Check Connections: Ensure all electrical connections to the motor remain secure and free from corrosion.
  • Inspect Auger: Check the auger for any signs of wear or damage that could impede pellet flow.
  • Follow Stove Manual: Adhere to the maintenance schedule and procedures outlined in your main Quadra-Fire pellet stove user manual.

Troubleshooting

If you experience issues with your pellet stove related to pellet feeding, consider the following troubleshooting steps:

ProblemPossible CauseSolution
"AUGER JAMMED" Error MessagePellet blockage in the auger, worn auger motor, or faulty optical sensor.Disconnect power, clear any pellet blockages from the auger. If the error persists, the motor or optical sensor may need replacement. (Refer to customer reviews for common causes and solutions related to this error).
No Pellets FeedingFeed motor not operating, empty hopper, or auger blockage.Check pellet level in hopper. Inspect auger for blockages. Verify electrical connections to the feed motor. If the motor is not turning, it may need replacement.
Unusual Noise from Feed MotorWorn motor bearings or foreign object in the auger mechanism.Disconnect power and inspect the auger area for foreign objects. If the noise persists and is coming from the motor itself, the motor may be failing and require replacement.

If troubleshooting steps do not resolve the issue, contact a qualified service technician or Quadra-Fire customer support.

Product Specifications

SpecificationDetail
Model NumberSRV7000-313
Product Dimensions7 x 6 x 5 inches
Item Weight14.9 ounces
ManufacturerQuadraFire
Voltage12 Volts
UPC652174513338

Warranty Information

The Quadra-Fire Mt. Vernon AE Feed Motor (SRV7000-313) comes with a 90-Day Manufacturer's Warranty. This warranty covers defects in materials and workmanship under normal use. For specific terms, conditions, and to make a warranty claim, please contact Quadra-Fire customer support or the authorized dealer from whom you purchased the product.

Customer Support

For further assistance, technical support, or inquiries regarding your Quadra-Fire Mt. Vernon AE Feed Motor, please contact Quadra-Fire customer service or your local authorized dealer. When contacting support, please have your stove model and the feed motor model number (SRV7000-313) available.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.