Best Price Square NT-312

Rate this product if you’ve used it
Download PDF
Contents

Pro'sKit NT-312 Digital Temperature/Humidity Meter with Probe User Manual

Model: NT-312

1. Introduction

The Pro'sKit NT-312 Digital Temperature/Humidity Meter is designed for monitoring ambient temperature and humidity. It features a large, easy-to-read LCD display that integrates temperature, humidity, clock, alarm clock, and calendar functions. This device also includes a memory function for maximum and minimum temperature and humidity readings, and offers selectable Celsius/Fahrenheit and 12-hour/24-hour display systems. It can be used as a wall-mounted unit or with its desk-top stand, and operates with low power consumption.

Pro'sKit NT-312 Digital Temperature/Humidity Meter front view

Figure 1: Front view of the Pro'sKit NT-312 Digital Temperature/Humidity Meter, showing the large LCD display with temperature and humidity readings.

2. Setup

2.1 Unpacking

Carefully remove the NT-312 meter and its probe from the packaging. Ensure all components are present: the main meter unit and the external temperature/humidity probe.

2.2 Battery Installation

  1. Locate the battery compartment cover on the back of the unit.
  2. Slide or unclip the cover to open it.
  3. Insert the required batteries (type not specified in provided data, typically AAA or AA) according to the polarity markings (+/-) inside the compartment.
  4. Replace the battery compartment cover securely.

2.3 Probe Connection

Connect the external probe cable into the designated port on the side of the main meter unit. Ensure the connection is firm.

External temperature and humidity probe with cable

Figure 2: The external probe and its connecting cable. This probe is used for external temperature and humidity measurements.

2.4 Placement

The NT-312 can be placed on a desk using its integrated stand or mounted on a wall. Choose a location that provides accurate readings, away from direct sunlight, heat sources, or strong drafts.

3. Operation

3.1 Display Overview

The large LCD displays current temperature, humidity, and time. Indicators for MAX/MIN readings, Celsius/Fahrenheit, and 12/24-hour format will also be visible.

Close-up of the meter's LCD display showing temperature and humidity

Figure 3: Close-up of the LCD display, highlighting temperature (top) and humidity (bottom) readings.

3.2 Button Functions

Close-up of the control buttons: MODE, ADJ, MEMORY

Figure 4: The control buttons located on the front of the unit: MODE, ADJ, and MEMORY.

  • MODE: Press to cycle through display modes (e.g., time, alarm, calendar). Long press to enter setting mode for time, alarm, or calendar.
  • ADJ (Adjust): Used to adjust values when in setting mode. Also used to switch between Celsius (°C) and Fahrenheit (°F) temperature units.
  • MEMORY: Press to view maximum (MAX) and minimum (MIN) recorded temperature and humidity values. Long press to clear recorded MAX/MIN data.

3.3 Setting Time and Date

  1. Press and hold the MODE button until the time display starts flashing.
  2. Use the ADJ button to set the hour.
  3. Press MODE again to move to minutes, then use ADJ to set.
  4. Continue pressing MODE to cycle through year, month, and day settings, adjusting each with the ADJ button.
  5. After setting all values, press MODE one last time to exit setting mode.

3.4 Switching Temperature Units (°C/°F)

In normal display mode, press the ADJ button to toggle between Celsius (°C) and Fahrenheit (°F).

3.5 Viewing and Clearing MAX/MIN Readings

  • Press the MEMORY button once to display the maximum recorded temperature and humidity.
  • Press MEMORY again to display the minimum recorded temperature and humidity.
  • Press MEMORY a third time to return to current readings.
  • To clear the MAX/MIN memory, press and hold the MEMORY button until the display resets.

4. Maintenance

4.1 Cleaning

Wipe the unit and probe with a soft, dry cloth. Do not use abrasive cleaners or immerse the unit in water. Keep the sensor area of the probe clean and free from dust or debris for accurate readings.

4.2 Battery Replacement

When the display becomes dim or the unit stops functioning, replace the batteries. Refer to section 2.2 for battery installation instructions. Dispose of old batteries responsibly.

5. Troubleshooting

  • No Display or Dim Display:
    • Check battery installation. Ensure batteries are inserted with correct polarity.
    • Replace old batteries with new ones.
  • Incorrect Temperature/Humidity Readings:
    • Ensure the external probe is securely connected.
    • Verify the probe is placed in the desired measurement area and not obstructed.
    • Note that the internal humidity sensor measures humidity inside the main unit's casing. For external humidity measurements, ensure the external probe is designed for and placed appropriately for humidity sensing.
    • Avoid placing the unit in direct sunlight, near heat sources, or in areas with extreme drafts.
  • Buttons Not Responding:
    • Remove and reinsert batteries to perform a soft reset.

6. Specifications

FeatureDetail
ModelNT-312
Temperature Range-10°C to +55°C (14°F to 130°F)
Temperature Accuracy0.5 (unit typically °C or °F)
DisplayLarge LCD
FunctionsTemperature, Humidity, Clock, Alarm Clock, Calendar, MAX/MIN Memory
Temperature UnitsCelsius (°C) / Fahrenheit (°F) selectable
Time Display12-hour / 24-hour selectable
Mounting TypeWall Mount / Desk Stand
Included ComponentsMeter and probe

7. Warranty and Support

For warranty information and technical support, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase. Specific warranty terms may vary by region and seller.

Pro'sKit NT-312 Digital Temperature/Humidity Meter User Manual. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?