1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of your Magnum Energy ME-AGS-N Automatic Generator Start (AGS) Module. The ME-AGS-N is designed to automatically start and stop a generator based on various configurable parameters, such as battery voltage, temperature, or time of day, ensuring your power system remains optimized.
Please read this manual thoroughly before attempting to install or operate the ME-AGS-N module. Retain this manual for future reference.
2. Product Overview
The Magnum Energy ME-AGS-N is a network-enabled automatic generator start module. It integrates seamlessly with compatible Magnum Energy inverters and accessories to provide intelligent generator control.

Figure 2.1: Front view of the Magnum Energy ME-AGS-N module, showing status indicators and connection ports.
Key Features:
- Status Indicator: A bi-color (Green or Red) LED indicator that illuminates to provide information on the AGS's operational status.
- Network Connection Port: An RJ14 port that provides the connection point for the network communication cable, allowing integration with other Magnum Energy devices.
- Remote Connection Port: An RJ14 port that provides the connection point for the remote temperature sensor cable, enabling temperature-based generator starting.
- GEN and POWER I/O: Terminal block for connecting to the generator's start/stop controls and power sensing.
- Test Button: Allows for manual testing of the generator start function.
3. Setup and Installation
Proper installation is crucial for the safe and reliable operation of the ME-AGS-N module. If you are not familiar with electrical systems, consult a qualified electrician or RV technician.
Safety Precautions:
- Always disconnect all power sources (battery, shore power, generator) before installation or servicing.
- Ensure proper ventilation around the module.
- Verify all wiring connections are secure and correct according to the wiring diagram provided in the full product manual.
- This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Handle with care and wash hands after handling.
Mounting the Module:
Mount the ME-AGS-N in a dry, protected location, away from direct sunlight, excessive heat, or moisture. Use appropriate fasteners for the mounting surface.
Wiring Connections:
- Power Connection: Connect the module to a 12V DC power source. Ensure correct polarity.
- Generator Control Wires: Connect the generator's start/stop control wires to the designated terminals on the ME-AGS-N. Refer to your generator's manual for specific wiring requirements.
- Network Cable: Connect an RJ14 network cable from the ME-AGS-N's Network Connection port to a compatible Magnum Energy device (e.g., inverter, remote control panel).
- Remote Temperature Sensor (Optional): If using, connect the remote temperature sensor cable to the Remote Connection port. Position the sensor in the desired location for temperature monitoring.

Figure 3.1: Detailed view of the ME-AGS-N connection ports and LED indicators.
4. Operating Instructions
Once installed and powered, the ME-AGS-N module can be configured and operated via a compatible Magnum Energy remote control panel (sold separately) or through its integrated test button.
Initial Power-Up:
Upon applying power, the status indicator LED will illuminate, indicating the module is active. Observe the LED for any error codes or operational status.
Configuring AGS Settings:
Detailed configuration of the Automatic Generator Start settings (e.g., battery voltage thresholds, quiet times, run times, temperature settings) is typically performed through a connected Magnum Energy remote control panel. Refer to the remote control panel's manual for specific programming instructions.
Using the Test Button:
The TEST button allows you to manually initiate a generator start sequence. Pressing this button will typically override current settings and attempt to start the generator. This is useful for verifying wiring and generator functionality.
Status Indicator Interpretation:
The bi-color LED provides quick visual feedback:
- Green: Indicates normal operation or specific status (refer to the full manual for detailed codes).
- Red: Indicates a fault condition or an active generator start request.
- Flashing Patterns: Different flashing patterns (green or red) convey specific operational states or error messages. Consult the comprehensive manual for a complete list of LED codes.
5. Maintenance
The Magnum Energy ME-AGS-N module is designed for minimal maintenance. Regular checks can help ensure its longevity and reliable operation.
- Visual Inspection: Periodically inspect the module and its connections for any signs of damage, corrosion, or loose wiring.
- Cleanliness: Keep the module free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners.
- Firmware Updates: Check the Magnum Energy website for any available firmware updates for your ME-AGS-N module. Updates may improve performance or add new features.
6. Troubleshooting
If the ME-AGS-N module is not functioning as expected, review the following common issues and solutions. For complex problems, contact Magnum Energy technical support.
Common Issues:
- Generator Does Not Start Automatically:
- Verify all wiring connections, especially to the generator's start/stop terminals.
- Check the AGS settings on your remote control panel. Ensure battery voltage thresholds, quiet times, and other parameters are correctly configured.
- Confirm the generator itself is in good working order and can be started manually.
- Ensure the module is receiving adequate power (12V DC).
- Generator Starts But Does Not Stop:
- Check the generator run time settings and battery charge parameters on your remote control panel.
- Inspect the generator's stop circuit wiring.
- Status LED Indicates an Error:
- Refer to the detailed LED error codes in the complete Magnum Energy ME-AGS-N manual for specific fault identification and resolution steps.
- No Communication with Remote Panel:
- Check the RJ14 network cable for secure connections and damage.
- Ensure both the ME-AGS-N and the remote panel are powered on.
7. Specifications
The following are the technical specifications for the Magnum Energy ME-AGS-N Automatic Generator Start Module:
| Specification | Value |
|---|---|
| Model Number | ME-AGS-N |
| Product Dimensions | 6 x 3 x 0.8 inches (15.24 x 7.62 x 2.03 cm) |
| Item Weight | 12.8 ounces (362.87 grams) |
| Manufacturer | Magnum Energy |
| Date First Available | November 13, 2012 |
| Operating Voltage | 12 Volts DC (nominal) |
8. What's in the Box
The Magnum Energy ME-AGS-N package typically includes the following components:
- ME-AGS-N Controller
- Remote Temperature Sensor
- Network Cable (RJ14)
- Operator's Manual (this document or a similar version)
9. Warranty and Support
For warranty information, technical support, or service inquiries, please contact Magnum Energy directly. Details regarding warranty coverage and support channels are typically provided with the product packaging or available on the official Magnum Energy website.
It is recommended to register your product upon purchase to facilitate warranty claims and receive important product updates.