Broan-NuTone S57769000

NuTone S57769000 Ceiling Heater Motor Instruction Manual

Model: S57769000

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of the NuTone S57769000 Ceiling Heater Motor. This motor is designed as a genuine replacement part for specific NuTone fan models. Please read this manual thoroughly before proceeding with installation or use.

2. Safety Information

WARNING: Risk of Electric Shock or Injury.

3. Product Overview

The NuTone S57769000 is a genuine replacement motor specifically designed for NuTone ceiling heater and fan units. It is engineered to restore the functionality of your existing unit by replacing a worn or defective motor. This motor features a shaft for attaching a blower cage and electrical connections for power.

NuTone S57769000 Ceiling Heater Motor with wiring and two ring lugs

Figure 1: NuTone S57769000 Ceiling Heater Motor. This image shows the motor unit with its shaft, mounting screws, and electrical wiring. Note the two ring lugs for connection, not a standard two-prong plug.

NuTone S57769000 Ceiling Heater Motor from a different angle

Figure 2: Another view of the NuTone S57769000 Ceiling Heater Motor, highlighting its compact design and connection points.

4. Compatibility

The S57769000 motor is compatible with the following NuTone fan and heater models:

Before purchasing and installing, verify that your existing unit's model number is listed above to ensure proper fit and function.

5. Installation Instructions

Tools Required:

Installation Steps:

  1. Disconnect Power: Locate the circuit breaker or fuse that supplies power to the ceiling heater/fan unit. Turn off the power completely. Verify power is off using a multimeter if available.
  2. Access the Unit: Carefully remove the grille and any other covers to access the internal components of the ceiling heater/fan unit. Refer to your specific unit's manual for detailed access instructions.
  3. Remove Old Motor:
    • Disconnect the electrical wires from the old motor. Note their connections for reinstallation. The S57769000 motor typically connects via two ring lugs, not a standard two-prong plug.
    • Loosen or remove any screws or clips securing the blower cage to the motor shaft. Carefully remove the blower cage.
    • Unscrew or unclip the old motor from its mounting bracket within the unit.
  4. Install New Motor:
    • Position the new S57769000 motor into the mounting bracket. Secure it with the appropriate screws or clips.
    • Attach the blower cage to the new motor shaft. Ensure it is seated correctly and tighten the hex key screw securely. Note: Some users have reported that the flat part of the shaft for clamping may not extend far enough. Ensure the screw is tightened firmly onto the rounded part of the shaft if necessary.
    • Connect the electrical wires to the new motor's ring lugs. Ensure connections are tight and secure.
  5. Reassemble Unit: Carefully replace any covers and the grille that were removed. Ensure all components are properly seated and secured.
  6. Restore Power: Turn the power back on at the circuit breaker or fuse box.
  7. Test Operation: Test the heater/fan unit to ensure the new motor operates correctly and quietly.

6. Operation

Once properly installed, the NuTone S57769000 Ceiling Heater Motor operates automatically as part of your NuTone ceiling heater/fan unit. When the unit is activated, the motor will power the fan to circulate air, either for ventilation or to distribute heated air, depending on the unit's function. No direct user interaction with the motor itself is required after installation.

7. Maintenance

Regular maintenance of your ceiling heater/fan unit helps prolong the life of the motor and ensures efficient operation. Always disconnect power before performing any maintenance.

8. Troubleshooting

ProblemPossible CauseSolution
Motor does not start or run.No power to the unit; loose wiring connection; defective motor.Check circuit breaker/fuse. Verify all wiring connections are secure. If power is present and connections are good, the motor may be defective and require replacement.
Motor runs but is noisy.Dust/debris in blower cage; loose blower cage; worn motor bearings.Disconnect power and clean blower cage. Ensure blower cage is securely fastened to the shaft. If noise persists, the motor bearings may be worn, indicating a need for replacement.
Motor runs slowly or weakly.Excessive dust/debris; motor nearing end of life.Disconnect power and clean blower cage and motor area. If the issue persists, the motor may be failing and require replacement.

9. Specifications

FeatureDetail
BrandBroan-NuTone
Model NameS57769000
Speed100 (RPM or other unit not specified, assumed relative)
Voltage120 Volts
MaterialCopper
Item Weight5.8 ounces (approx. 164 grams)
Product Dimensions7 x 3 x 3 inches (approx. 17.8 x 7.6 x 7.6 cm)
ManufacturerQ2U LLC, formerly Davelle
UPC026715190652, 885524535562
ASINB00A5USZXY

10. Warranty Information

Specific warranty details for the NuTone S57769000 Ceiling Heater Motor are not provided in this manual. For information regarding warranty coverage, terms, and conditions, please refer to the documentation included with your original NuTone ceiling heater/fan unit or contact Broan-NuTone customer support directly.

11. Customer Support

If you require further assistance, have questions about installation, or need to troubleshoot an issue not covered in this manual, please contact Broan-NuTone customer support.

Broan-NuTone Official Website: www.broan-nutone.com

Please have your product model number (S57769000) and the model number of your NuTone ceiling heater/fan unit ready when contacting support.

Related Documents - S57769000

Preview Broan-NuTone 765H80L/765H80LB Heater Fan Light Installation Guide
Installation, operation, and maintenance guide for Broan-NuTone 765H80L and 765H80LB Heater/Fan/Light units. Learn how to safely install and use this bathroom ventilation and heating solution.
Preview Broan-NuTone Models 120, 124, 128 Register Heaters Installation and User Manual
Comprehensive installation, operation, maintenance, and warranty guide for Broan-NuTone Models 120, 124, and 128 register heaters. Includes safety instructions, wiring diagrams, and parts list.
Preview ChromaComfort & Sensonic Fan/Light/Speaker Installation Instructions
Comprehensive installation guide for the ChromaComfort & Sensonic Fan/Light/Speaker, detailing safety precautions, cleaning, maintenance, operation, and step-by-step installation for both new and retrofit applications. Includes Bluetooth pairing and app download information.
Preview Broan-NuTone Economy Energy Star Ceiling/Wall Fan Installation and Operation Guide
Comprehensive installation and operation instructions for Broan-NuTone Economy Energy Star Ceiling/Wall Fans, including models 688E, 6884E, 696N, and 696NE. Covers safety warnings, installation procedures for new construction and retrofits, electrical wiring, ducting, finishing, and maintenance.
Preview Broan-NuTone 688E/696N Ceiling and Wall Fan Installation Guide
This document provides installation instructions for Broan-NuTone Economy Energy Star and Non-Energy Star ceiling and wall fans, models 688E and 696N. It includes essential safety warnings, electrical wiring guidance, ducting requirements, and step-by-step mounting procedures for both new construction and replacement installations.
Preview Broan-NuTone 695 & 696N Ceiling/Wall Ventilating Units Installation Guide
Comprehensive installation guide for Broan-NuTone 695 and 696N ceiling and wall ventilating units. Includes safety warnings, step-by-step installation instructions, and warranty information.