3M 6002

3M Respirator Cartridge 6002 User Manual

Model: 6002 | Brand: 3M

Introduction

The 3M™ Acid Gas Cartridge 6002 is designed to provide respiratory protection against certain acid gases in various environments. When used correctly with an approved and properly fitted 3M respirator, this cartridge helps protect against gases such as chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, and hydrogen sulfide.

This manual provides essential information for the safe and effective use of your 3M Respirator Cartridge 6002. Please read it thoroughly before use.

Important Safety Information and Warnings

WARNING: These respirators help to protect against certain airborne contaminants. Before use, the wearer must read and understand the User Instructions provided as part of the product packaging. A written respiratory protection program must be implemented meeting all the requirements of OSHA 1910.134 including training, fit testing and medical evaluation. In Canada, CSA standards Z94.4 requirements must be met and/or requirements of applicable jurisdiction, as well as all product literature, user instructions, warnings, and other limitations. Improper use may result in injury, sickness, death, or property damage.

For industrial/occupational use only. Not for consumer sale or use.

  • Do not use in environments that are immediately dangerous to life or health (IDLH).
  • Always ensure the respirator is properly fitted and sealed to the face.
  • Consult your on-site safety professional, industrial hygienist, or other subject matter expert for product selection and use.

Product Overview

The 3M Respirator Cartridge 6002 is a NIOSH-approved cartridge designed for respiratory protection against specific acid gases. Its swept-back design enhances the field of view and wearer comfort.

Diagram of 3M Respirator Cartridge 6002

Figure 1: Diagram of the 3M Respirator Cartridge 6002, showing its distinctive swept-back shape and bayonet connection points.

Key Features:

  • NIOSH approved against certain acid gases (chlorine, hydrogen chloride, sulfur dioxide, chlorine dioxide, or hydrogen sulfide).
  • Swept-back design for enhanced field of view and increased comfort.
  • Easy twist-on and twist-off bayonet connection for quick assembly and disassembly.

Compatibility:

This cartridge is compatible with 3M Half and Full Facepieces 6000, 7000, and FF-400 Series with bayonet holders. It can also be used with 3M Scott AV-3000 HT and AV-3000 SureSeal facepieces when used with a 3M Scott AV-632 Bayonet Adapter.

3M Half Facepiece Respirator with cartridges attached

Figure 2: A 3M Half Facepiece Respirator, demonstrating where the 6002 cartridges would attach.

Setup and Installation

Proper installation of the 3M Respirator Cartridge 6002 is crucial for effective respiratory protection. Always refer to the specific user instructions for your 3M facepiece for detailed guidance.

Installation Steps:

  1. Inspect Cartridges: Before each use, inspect the cartridges for any damage, cracks, or signs of wear. Ensure the expiration date has not passed.
  2. Align Cartridge: Hold the respirator facepiece in one hand and align the bayonet fitting of the 6002 cartridge with the corresponding receptacle on the facepiece.
  3. Twist to Secure: Push the cartridge onto the receptacle and twist clockwise until it clicks into place. Ensure it is securely fastened and cannot be easily removed.
  4. Repeat for Second Cartridge: If using a dual-cartridge respirator, repeat the process for the second cartridge on the opposite side.
  5. Perform Seal Check: After installation, always perform a positive and/or negative pressure user seal check as described in your respirator's user manual to ensure a proper face-to-respirator seal.

Video 1: This video demonstrates the features and easy installation process of the 3M Acid Gas Cartridge 6002 onto a compatible 3M respirator.

Operating Instructions

The 3M Respirator Cartridge 6002 functions by filtering acid gases from the air as you breathe. It is crucial to use the cartridge only in environments for which it is approved and within its specified protection limits.

Proper Use:

  • Ensure the respirator and cartridges are correctly assembled and a proper seal is achieved before entering a contaminated area.
  • Use for vapor concentrations up to 10 times the Permissible Exposure Limit (PEL) with half facepieces or 50 times PEL with quantitatively fit tested full facepieces.
  • Do not use if you can smell or taste contaminants, or if dizziness or irritation occurs. Immediately leave the contaminated area and replace cartridges.
  • The cartridge is designed for protection against acid gases only. It does not protect against particulates unless combined with appropriate particulate filters.

Recommended Applications:

  • Chemical manufacturing
  • Glass etching
  • Pulp and paper industries
  • Laboratories
  • Assembly and mechanical tasks
  • Batch-charging
  • Change-overs
  • Chemical dispensing
  • Clean-up operations
  • Electro-plating

Video 2: This video highlights the importance of proper respirator fit for effective protection, a critical aspect of using the 3M Respirator Cartridge 6002.

Maintenance

The 3M Respirator Cartridge 6002 is a disposable component and cannot be cleaned or reused indefinitely. Proper maintenance primarily involves timely replacement and correct storage.

Cartridge Replacement:

  • Replace cartridges when you detect the odor, taste, or irritation of contaminants.
  • Replace cartridges according to your company's respiratory protection program schedule, or sooner if breakthrough occurs.
  • Always replace both cartridges at the same time.
  • Dispose of used cartridges according to local regulations for hazardous waste, if applicable.

Storage:

  • Store unused cartridges in their original packaging in a cool, dry place away from contaminants and direct sunlight.
  • Ensure the storage area is free from chemicals that could degrade the cartridge material.

Troubleshooting

If you experience issues while using the 3M Respirator Cartridge 6002, consult the following common troubleshooting steps:

ProblemPossible CauseSolution
Smell or taste of contaminantsCartridge breakthrough, improper seal, or expired cartridge.Immediately leave the contaminated area. Check respirator fit and seal. Replace cartridges.
Difficulty breathingCartridges are clogged or saturated, or respirator is not properly maintained.Immediately leave the contaminated area. Replace cartridges. Ensure respirator is clean.
Cartridge does not attach securelyIncorrect alignment, damaged bayonet fitting on cartridge or facepiece.Re-align and twist firmly. Inspect both cartridge and facepiece for damage. Replace damaged components.

If problems persist, discontinue use and consult your safety supervisor or 3M Technical Service.

Specifications

AttributeDetail
Model Number6002
Protection TypeAcid Gas (Chlorine, Hydrogen Chloride, Sulfur Dioxide, Chlorine Dioxide, Hydrogen Sulfide)
ApprovalNIOSH approved
Connection TypeBayonet
Color CodeWhite (NIOSH system)
Product Dimensions6.5 x 4 x 0.8 inches
Item Weight7.4 ounces (for the pair)
MaterialGlass (likely referring to filter media components, not the casing)

Warranty and Support

For specific warranty information regarding the 3M Respirator Cartridge 6002, please refer to the documentation included with your purchase or contact 3M directly. As a consumable item, cartridges typically have a limited shelf life and are subject to replacement based on usage and exposure.

Technical Support:

For assistance with product selection, use, or any technical inquiries, please contact 3M PSD Technical Service:

  • In USA: 1-800-243-4630
  • In Canada: 1-800-267-4414

Additional product information can be found at www.3M.com.

© 2024 3M. All rights reserved. All trademarks are property of their respective owners.