Paragon Controls 8045-00

Paragon D-FROST-O-MATIC™ Time Control Instruction Manual

Model: 8045-00

Introduction

The Paragon 8045-00 D-FROST-O-MATIC™ Time Control is a robust and reliable device designed for commercial freezers and refrigerators. It provides automatic defrost capabilities, supporting various defrost systems including electric defrost heaters, hot gas, and compressor off-cycle methods. This manual outlines the necessary steps for safe installation, proper operation, and routine maintenance of your defrost timer.

Safety Information

CAUTION - RISK OF ELECTRIC SHOCK:

  • DISCONNECT ALL POWER AT THE MAIN PANEL BEFORE REMOVING THE INSULATOR.
  • MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE-ENERGIZE THE DEVICE FOR SERVICING.
  • REPLACE THE INSULATOR AFTER WIRING.

Use copper conductors only. Ensure all wiring complies with local electrical codes and the specifications provided.

Specifications

FeatureSpecification
Electrical Rating120V AC, 60 Hz
Timing Motor120V 60 Hz
EnclosureHeavy Duty Steel
Adjustable Length of Defrost4-110 minutes (in 2-minute increments)
Switching1 N.O. (Normally Open) - 1 N.C. (Normally Closed)
High-Amp Switch Contacts40 Amps, 2 HP
Adjustable Frequency of Defrost Initiation1 to 6 cycles per day (minimum 4 hours between successive operations)
Maximum Contact Rating (Non-Inductive)40A @ 120 Vac
Maximum Contact Rating (Pilot Duty)2HP @ 120 Vac, 20A @ 120 Vac

Product Overview

Image of the Paragon 8045-00 D-FROST-O-MATIC Time Control with its cover open, showing the internal dial and wiring terminals.

This image displays the Paragon 8045-00 D-FROST-O-MATIC Time Control unit. The grey metal enclosure is open, revealing the internal components. On the right, a large circular dial with numbers 1-12 (for hours) and smaller markings (for minutes) is visible, used for setting time and defrost cycles. Below the dial are brass screw terminals labeled N, 1, 2, 3, 4, and an X, indicating wiring connections. The inside of the cover on the left contains a wiring diagram and important safety warnings regarding electrical shock and proper conductor use. The model number '8045-00' and 'D-FROST-O-MATIC™ TIME CONTROL' are clearly printed on the unit.

Setup

Before beginning installation, ensure all power to the circuit is disconnected at the main panel. Refer to the wiring diagram located inside the unit's cover for correct connections. Use only copper conductors of the specified gauge.

Installing and Operating Directions:

Place start pins in the outer (24-hour) dial at the desired time of day. Note that switch contacts are reversed from the shown configuration when dial pins are opposite the time pointer.

Operating Instructions

To Set Mechanical Defrost Termination:

Push down and rotate the pointer on the inner (2-hour) dial until it aligns with the desired termination time. Ensure proper spacing between settings on the dial.

To Set Time of Day:

Grasp the knob in the center of the inner (2-hour) dial and rotate it in a counter-clockwise direction. This action will revolve the outer dial. Line up the correct time of day on the outer dial with the time pointer. Do not attempt to set the time control by grasping the outer dial; rotate the inner dial only.

Maintenance

To Remove Movement from Case:

Press the spring clip at the right center of the case and lift the movement out.

To Replace Movement in Case:

Insert the tabs on the left side of the time switch plate into the holes in the side of the case. Push down and snap into place.

Troubleshooting

If the unit is not functioning as expected, first verify that all power connections are secure and that the correct voltage is supplied. Check the dial settings to ensure they are configured properly for your defrost schedule. For persistent issues, consult a qualified electrician or refrigeration technician.

Warranty and Support

For replacement of this control or for any support inquiries, please contact the refrigerator manufacturer or your authorized Paragon Controls dealer. Refer to your product's purchase documentation for specific warranty terms and conditions.

Related Documents - 8045-00

Preview FIT-1001-DZV Air Volume/Velocity Transducer Operation and Maintenance Manual
This manual provides comprehensive information on the features, installation, calibration, and troubleshooting of the FIT-1001-DZV Air Volume/Velocity Transducer with Digital Indication and Manual Zeroing Valve by Paragon Controls.
Preview Guardian Space Pressure Monitor Operation and Maintenance Manual
This manual provides detailed operational and maintenance instructions for the Paragon Controls Guardian Space Pressure Monitor with Remote Auxiliary Alarm. It covers system features, configuration settings, pre-startup checks, and calibration procedures for accurate pressure monitoring.
Preview Paragon Controls DPT-4003 Differential Pressure Transducer Technical Data Sheet
Technical data sheet for the Paragon Controls DPT-4003 Differential Pressure Transducer. This device operates on the capacitance principal for sensing ultra-low differential pressures, offering features like selectable output, high accuracy, and wide operating temperature ranges.
Preview Paragon 8000 Series Mechanical Defrost Timer: Features, Specifications, and Wiring Diagrams
Detailed overview of the Paragon 8000 Series Mechanical Defrost Timer, including features, benefits, ordering information, specifications, and wiring diagrams for commercial refrigeration applications. Learn about models 8040 and 8140 series.
Preview Paragon 8000 Series Auto Voltage Defrost Timer Installation Data
Installation data and operating instructions for the Paragon 8000 Series Auto Voltage Defrost Timer. Includes wiring diagrams, supply connection specifications, contact ratings, and model-specific terminal assignments for various defrost configurations.
Preview Paragon 8000 Series Mechanical Defrost Timer - Specifications and Wiring Diagrams
Explore the Paragon 8000 Series Mechanical Defrost Timer. This document provides comprehensive features, benefits, ordering details, technical specifications, and detailed wiring diagrams for commercial refrigeration applications.