APC Back-UPS BK500 CS 500VA Uninterruptible Power Supply User Manual

Model: BK500

1. Introduction

The APC Back-UPS BK500 CS 500VA is an Uninterruptible Power Supply (UPS) designed to provide power protection for your electronic equipment. It safeguards against power surges, spikes, and sags, and provides temporary battery power during power outages. This manual provides essential information for the safe and efficient use of your Back-UPS unit.

2. Safety Information

Please read these instructions carefully before installing or operating the Back-UPS unit. Keep this manual for future reference.

  • This UPS is intended for indoor use only.
  • Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or humidity.
  • Connect the UPS power cable directly to a wall outlet. Do not use extension cords or surge protectors.
  • Ensure the wall outlet is properly grounded.
  • Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions. Keep unauthorized personnel away from batteries.
  • Do not dispose of batteries in a fire. The batteries may explode.
  • Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic.
  • A battery can present a risk of electrical shock and high short-circuit current. The following precautions should be observed when working on batteries:
    1. Remove watches, rings, or other metal objects.
    2. Use tools with insulated handles.
    3. Wear rubber gloves and boots.

3. Setup

3.1 Unpacking and Inspection

Carefully unpack the Back-UPS unit and inspect it for any shipping damage. If any damage is found, notify the carrier and dealer. The package should contain the Back-UPS unit, a user manual, and a USB communication cable.

3.2 Connecting to Power

Connect the Back-UPS power cord directly to a properly grounded 120V AC wall outlet. Avoid using extension cords or surge strips. The unit will begin charging its internal battery. Allow the battery to charge for at least 8 hours before connecting equipment to ensure adequate runtime capacity.

3.3 Connecting Equipment

The Back-UPS BK500 CS features six outlets, divided into two types:

  • Battery Backup & Surge Protection Outlets (3 outlets): Connect critical equipment such as your computer, monitor, and external hard drives to these outlets. These devices will receive battery power during an outage and are protected from surges.
  • Surge Protection Only Outlets (3 outlets): Connect non-critical equipment like printers, scanners, or speakers to these outlets. These devices are protected from surges but will not receive battery power during an outage.

Refer to the diagram below for outlet identification.

Rear view of APC Back-UPS BK500 CS showing six outlets, divided into three battery backup and three surge protection only outlets. Also visible are data ports and a circuit breaker.

Figure 3.3.1: Rear panel of the APC Back-UPS BK500 CS, illustrating the layout of battery backup and surge-only outlets, along with data line protection ports.

Close-up of the APC Back-UPS BK500 CS rear panel, highlighting the Wall Outlet, Modem/Phone/Fax, and Data Port connections, as well as the Circuit Breaker reset button and Building Wiring Fault indicator.

Figure 3.3.2: Detailed view of the APC Back-UPS BK500 CS rear panel, showing connection points for power input, data line protection, and the circuit breaker.

3.4 Data Line Protection

The Back-UPS provides protection for a single phone/fax/modem line. Connect your incoming phone line to the "Wall Outlet" jack and connect your modem/phone/fax to the "Modem/Phone/Fax" jack. This protects your equipment from surges traveling along the data line.

3.5 USB Communication

Connect the supplied USB cable from the Back-UPS to your computer's USB port. This allows your computer to communicate with the Back-UPS for automatic shutdown during extended power outages and for monitoring power conditions. Install the PowerChute Personal Edition software (available from APC's website) for full functionality.

Side view of the APC Back-UPS BK500 CS with its power cord connected, showing the compact form factor and the rear panel connections.

Figure 3.5.1: Side profile of the APC Back-UPS BK500 CS, illustrating its physical dimensions and the integrated power cord.

4. Operating the Back-UPS

4.1 Powering On/Off

To turn on the Back-UPS, press the ON/OFF button located on the front panel. The unit will emit a short beep, and the "On Line" indicator will illuminate. To turn off the Back-UPS, press and hold the ON/OFF button until the unit beeps and the "On Line" indicator turns off.

4.2 Indicators and Alarms

  • On Line Indicator (Green LED): Illuminates when the Back-UPS is supplying utility power to connected equipment.
  • On Battery Indicator (Yellow LED): Illuminates and the unit beeps when the Back-UPS is supplying battery power during an outage. The beeping will become more frequent as the battery charge depletes.
  • Overload Indicator (Red LED): Illuminates and the unit emits a continuous tone if the connected load exceeds the Back-UPS's capacity. Disconnect non-essential equipment immediately.
  • Building Wiring Fault Indicator (Red LED on rear): Illuminates if there is a wiring problem in the wall outlet (e.g., missing ground, reversed polarity). Consult a qualified electrician to correct the wiring.

4.3 Circuit Breaker

The Back-UPS is equipped with a resettable circuit breaker located on the rear panel. If an overload condition occurs and the circuit breaker trips, disconnect some equipment from the Back-UPS, then push the circuit breaker button to reset it. Refer to Figure 3.3.2 for the location of the circuit breaker.

5. Maintenance

5.1 Battery Replacement

The battery in the Back-UPS BK500 CS is user-replaceable. The typical battery life is 3-5 years, depending on usage and environmental conditions. When the battery needs replacement, the unit will typically indicate this with an audible alarm and/or an illuminated "Replace Battery" indicator (if present on the model). Refer to the APC website or contact customer support for information on purchasing replacement batteries and detailed replacement instructions. Always use genuine APC replacement batteries.

5.2 Cleaning

Clean the exterior of the Back-UPS with a soft, damp cloth. Do not use abrasive cleaners or solvents. Ensure the unit is turned off and unplugged from the wall outlet before cleaning.

5.3 Storage

If storing the Back-UPS for an extended period, ensure the battery is fully charged. Store the unit in a cool, dry location with the battery disconnected (if possible) or recharge the battery every 3-6 months to prevent permanent damage and maintain battery life.

6. Troubleshooting

ProblemPossible CauseSolution
Back-UPS will not turn on.Not connected to utility power; battery discharged; internal fault.Ensure power cord is securely plugged into a live wall outlet. Allow battery to charge for 8 hours. If problem persists, contact APC support.
Back-UPS operates on battery power frequently.Frequent power fluctuations; low utility voltage.This is normal operation if utility power is unstable. If it happens excessively, consult an electrician to check building wiring.
Back-UPS emits a continuous tone and Overload LED is on.Overload condition.Disconnect non-essential equipment from battery backup outlets. Push the circuit breaker button to reset.
Building Wiring Fault LED is illuminated.Wiring problem in wall outlet.Consult a qualified electrician to inspect and correct the building wiring. Do not use the outlet until corrected.
Short battery runtime.Battery not fully charged; battery nearing end of life; excessive load.Allow battery to charge for 8 hours. Reduce connected load. Consider replacing the battery if it's old.

7. Specifications

FeatureDetail
ModelBK500 CS
Output Power Capacity500VA / 300 Watts
Nominal Output Voltage120V AC
Nominal Input Voltage120V AC
Number of Outlets6 (3 Battery Backup & Surge Protection, 3 Surge Protection Only)
Typical Runtime (Full Load)3 minutes
Communication PortUSB
Data Line ProtectionRJ-11 Modem/Fax/DSL protection
Item Weight14.3 Pounds (6.5 kg)
Form FactorCompact
ColorBeige
Typical Recharge Time8 hours (for 90% capacity)
Battery TypeMaintenance-free sealed Lead-Acid battery

8. Warranty and Support

APC provides a standard warranty for this product. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official APC website. For technical support, product registration, or to find authorized service centers, please visit www.apc.com/support.

When contacting support, please have your model number (BK500 CS) and serial number ready.

© 2023 APC by Schneider Electric. All rights reserved.

This manual is subject to change without notice.