Altech 101279230

Altech 101279230 Submersible Pump for Dirty Water

Instruction Manual

1. Introduction

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Altech 101279230 submersible pump. This pump is specifically designed for lifting wastewater containing solid particles. Please read these instructions carefully before using the product and retain them for future reference.

Altech 101279230 submersible pump for dirty water, showing its blue and black casing, float switch, and discharge outlet.

This image displays the Altech 101279230 submersible pump. It features a robust blue top section and a black lower body, designed for durability. A black float switch is visible on the left, connected by a cable, which controls the pump's automatic operation. On the right, a black elbow connector serves as the discharge outlet for the pumped water.

2. Safety Instructions

Always observe the following safety precautions to prevent injury or damage to the pump:

3. Package Contents

Upon unpacking, verify that all components are present and undamaged:

4. Setup

  1. Placement: Position the pump on a stable, level surface in the area to be drained. Ensure the pump's intake is clear of large debris that could obstruct it.
  2. Hose Connection: Attach a suitable discharge hose to the pump's outlet connector. Secure the hose with a clamp if necessary to prevent leaks. Ensure the hose is routed away from the pumping area to a suitable discharge point.
  3. Float Switch Adjustment: The float switch controls the pump's automatic on/off cycles based on water level. Adjust the cable length of the float switch to set the desired minimum and maximum water levels for operation. Ensure the float switch can move freely without obstruction.
  4. Power Connection: Once the pump is positioned and the hose is connected, plug the 10-meter power cable into a grounded electrical outlet. Ensure the outlet is protected by a residual current device (RCD) for safety.

5. Operating Instructions

The Altech 101279230 pump operates in automatic mode, controlled by its integrated float switch.

6. Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump.

  1. Cleaning the Intake: Disconnect the pump from the power supply. Regularly inspect and clean the pump's intake screen to remove any accumulated debris (leaves, mud, small stones) that could impede water flow or damage the impeller.
  2. Housing and Cable Inspection: Periodically check the pump housing and power cable for any signs of damage, cracks, or wear. Do not use the pump if any damage is found.
  3. Float Switch Check: Ensure the float switch moves freely and is not obstructed by debris.
  4. Winter Storage: Before storing the pump for extended periods, especially during freezing temperatures, thoroughly clean it and drain all water. Store the pump in a dry, frost-free location.

7. Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power supply
Float switch not activated
Impeller blocked
Check power connection and circuit breaker
Ensure water level is high enough to activate float switch
Disconnect power, clean intake and impeller area
Pump runs but delivers little or no waterDischarge hose kinked or blocked
Intake screen blocked
Air lock
Check and clear discharge hose
Disconnect power, clean intake screen
Slightly tilt the pump to release trapped air
Pump runs continuouslyFloat switch stuck in 'on' position
Water level not dropping below 'off' level
Disconnect power, check float switch for obstructions
Verify discharge is effective and water can drain away
Motor stops during operationOverheating (thermal protection activated)
Power interruption
Disconnect power, allow pump to cool down, check for blockages
Check power supply

8. Specifications

FeatureDetail
BrandAltech
Model Number101279230
ManufacturerALTECH
Power1000 W
Max Flow Rate14.4 m³/h
Max Head10 meters
Protection IndexIP68
Insulation ClassF
Cable Length10 meters
Item Weight6.22 kg
ColorBlue
Power SourceElectric Cable

9. Warranty and Support