Introduction
This manual provides comprehensive instructions for the safe installation, efficient operation, and proper maintenance of your Air King AK80H Energy Star Quiet Series Humidity Sensing Bath Fan. Please read all instructions carefully before beginning installation or use to ensure optimal performance and safety.
Safety Information
WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:
- Always disconnect power at the service panel before servicing or cleaning the unit.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes.
- Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
- Do not use this fan with any solid-state speed control device.
- This fan is UL-listed for safe installation over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit.
- Ensure proper ventilation is provided for combustion air needed for fuel burning equipment to prevent back-drafting.
Package Contents
Verify that all components are present before beginning installation:
- Air King AK80H Bath Fan Unit
- Grille
- Adjustable Hanging Brackets
- 4-inch Round Plastic Duct Connector with Damper
- Installation Hardware (screws, wire nuts, etc. - typically included)
Specifications
| Model | AK80H |
| Air Flow Capacity (CFM) | 80 CFM |
| Sound Level (Sones) | 1.0 Sones |
| Voltage | 115 Volts |
| Amperage | 0.3 - 0.31 Amps |
| Duct Size | 4-inch Round |
| Housing Dimensions (L x W x D) | 10.875" x 9.375" x 7.875" |
| Grille Dimensions (L x W) | 13.75" x 11" |
| Item Weight | 11.5 Pounds |
| Special Features | Humidity Sensing Humidistat, Quiet Operation, Low-Profile Contoured Grill |
| Certifications | Energy Star, HVI-Certified, UL-Listed (for tub/shower with GFCI), California Title 24, ASHRAE 62.2, ARRA, CAL Green Compliant, LEED for Homes |
| Recommended Ventilation Area | Approximately 75 to 100 square feet |
Installation
This section outlines the general steps for installing the Air King AK80H bath fan. Professional installation is recommended for electrical wiring.
Mounting the Fan Housing
- Prepare Opening: Create an appropriate opening in the ceiling for the fan housing (10.875" L x 9.375" W).
- Attach Hanging Brackets: Utilize the included adjustable hanging brackets to secure the fan housing between ceiling joists. Ensure the housing is level and firmly attached.
- Connect Ductwork: Attach a 4-inch round duct to the fan's duct connector. The connector includes a damper for backdraft protection. Secure the duct with appropriate clamps or tape (not included).
Electrical Wiring
- Disconnect Power: Ensure power to the circuit is OFF at the service panel before proceeding.
- Access Wiring: The fan features a side access panel for easy wiring without removing internal components. Open this panel.
- Connect Wires: Connect the household wiring to the fan's wiring according to local electrical codes. Typically, this involves connecting live, neutral, and ground wires. If installing over a tub or shower, ensure the circuit is GFCI protected.
- Secure Connections: Use appropriate wire connectors and ensure all connections are secure. Close the access panel.
Installing the Grille
- Once the fan housing is installed and wired, attach the grille to the fan housing. Typically, grilles attach with spring clips or screws.

Figure 1: The Air King AK80H bath fan unit, showing the white contoured grille, the metal housing, and the black 4-inch round duct connector on top. This image illustrates the overall appearance and key components of the fan before installation.
Operation
The Air King AK80H features an integrated humidity sensor for automatic operation.
- Automatic Humidity Sensing: The fan's integrated humidistat continuously monitors the humidity level in the room. When the humidity level reaches a preset threshold, the fan will automatically activate.
- Automatic Shut-off: Once the humidity level drops below the preset threshold, the fan will automatically turn off. This ensures efficient operation and prevents unnecessary energy consumption.
- Quiet Operation: The fan operates at a quiet 1.0 sone level, providing effective ventilation without significant noise disruption.
- Manual Override (if applicable): Depending on your wiring configuration, a separate wall switch may provide manual ON/OFF control, overriding the humidity sensor. Consult your electrician for specific wiring options.
Maintenance
Regular maintenance ensures optimal performance and longevity of your bath fan. Always disconnect power before performing any maintenance.
Cleaning the Grille
- Gently pull down the grille to disengage its mounting springs.
- Wash the grille with mild soap and water. Rinse thoroughly and dry completely before reattaching.
Cleaning the Fan Motor and Housing
- With the grille removed and power disconnected, use a vacuum cleaner with a brush attachment to remove dust and debris from the fan blades and interior of the housing.
- Wipe down surfaces with a damp cloth if necessary. Do not allow water to enter the motor or electrical components.
- Ensure all parts are dry before restoring power and reattaching the grille.
Troubleshooting
If your Air King AK80H bath fan is not operating correctly, consult the following troubleshooting guide:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power to the unit. Humidity level below threshold. Faulty wiring connection. | Check circuit breaker/fuse. Increase humidity (e.g., run shower) to test sensor. Verify all electrical connections are secure (consult electrician). |
| Fan runs continuously. | Humidity level consistently high. Humidity sensor malfunction. | Ensure proper room sealing and ventilation. If humidity is low and fan still runs, contact customer support for sensor evaluation. |
| Fan is unusually noisy. | Accumulation of dust/debris on fan blades. Loose mounting. Motor issue. | Clean fan blades and housing (see Maintenance). Ensure fan housing is securely mounted. If noise persists, contact customer support. |
| Humidity sensor not responding correctly. | Sensor malfunction or wiring issue. | Verify wiring to the sensor. If issues persist, the sensor may need replacement. Contact customer support. |
Warranty and Support
The Air King AK80H bath fan comes with a 5-year limited warranty. This warranty covers defects in materials and workmanship under normal use.
For warranty claims, technical assistance, or replacement parts, please contact Air King customer support. Keep your proof of purchase for warranty validation.