Air King AK80H

Air King AK80H Energy Star Quiet Series Humidity Sensing Bath Fan User Manual

Introduction

This manual provides comprehensive instructions for the safe installation, efficient operation, and proper maintenance of your Air King AK80H Energy Star Quiet Series Humidity Sensing Bath Fan. Please read all instructions carefully before beginning installation or use to ensure optimal performance and safety.

Safety Information

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

Package Contents

Verify that all components are present before beginning installation:

Specifications

ModelAK80H
Air Flow Capacity (CFM)80 CFM
Sound Level (Sones)1.0 Sones
Voltage115 Volts
Amperage0.3 - 0.31 Amps
Duct Size4-inch Round
Housing Dimensions (L x W x D)10.875" x 9.375" x 7.875"
Grille Dimensions (L x W)13.75" x 11"
Item Weight11.5 Pounds
Special FeaturesHumidity Sensing Humidistat, Quiet Operation, Low-Profile Contoured Grill
CertificationsEnergy Star, HVI-Certified, UL-Listed (for tub/shower with GFCI), California Title 24, ASHRAE 62.2, ARRA, CAL Green Compliant, LEED for Homes
Recommended Ventilation AreaApproximately 75 to 100 square feet

Installation

This section outlines the general steps for installing the Air King AK80H bath fan. Professional installation is recommended for electrical wiring.

Mounting the Fan Housing

  1. Prepare Opening: Create an appropriate opening in the ceiling for the fan housing (10.875" L x 9.375" W).
  2. Attach Hanging Brackets: Utilize the included adjustable hanging brackets to secure the fan housing between ceiling joists. Ensure the housing is level and firmly attached.
  3. Connect Ductwork: Attach a 4-inch round duct to the fan's duct connector. The connector includes a damper for backdraft protection. Secure the duct with appropriate clamps or tape (not included).

Electrical Wiring

  1. Disconnect Power: Ensure power to the circuit is OFF at the service panel before proceeding.
  2. Access Wiring: The fan features a side access panel for easy wiring without removing internal components. Open this panel.
  3. Connect Wires: Connect the household wiring to the fan's wiring according to local electrical codes. Typically, this involves connecting live, neutral, and ground wires. If installing over a tub or shower, ensure the circuit is GFCI protected.
  4. Secure Connections: Use appropriate wire connectors and ensure all connections are secure. Close the access panel.

Installing the Grille

  1. Once the fan housing is installed and wired, attach the grille to the fan housing. Typically, grilles attach with spring clips or screws.
Air King AK80H Bath Fan with Grille and Duct Connector

Figure 1: The Air King AK80H bath fan unit, showing the white contoured grille, the metal housing, and the black 4-inch round duct connector on top. This image illustrates the overall appearance and key components of the fan before installation.

Operation

The Air King AK80H features an integrated humidity sensor for automatic operation.

Maintenance

Regular maintenance ensures optimal performance and longevity of your bath fan. Always disconnect power before performing any maintenance.

Cleaning the Grille

  1. Gently pull down the grille to disengage its mounting springs.
  2. Wash the grille with mild soap and water. Rinse thoroughly and dry completely before reattaching.

Cleaning the Fan Motor and Housing

  1. With the grille removed and power disconnected, use a vacuum cleaner with a brush attachment to remove dust and debris from the fan blades and interior of the housing.
  2. Wipe down surfaces with a damp cloth if necessary. Do not allow water to enter the motor or electrical components.
  3. Ensure all parts are dry before restoring power and reattaching the grille.

Troubleshooting

If your Air King AK80H bath fan is not operating correctly, consult the following troubleshooting guide:

ProblemPossible CauseSolution
Fan does not turn on.No power to the unit.
Humidity level below threshold.
Faulty wiring connection.
Check circuit breaker/fuse.
Increase humidity (e.g., run shower) to test sensor.
Verify all electrical connections are secure (consult electrician).
Fan runs continuously.Humidity level consistently high.
Humidity sensor malfunction.
Ensure proper room sealing and ventilation.
If humidity is low and fan still runs, contact customer support for sensor evaluation.
Fan is unusually noisy.Accumulation of dust/debris on fan blades.
Loose mounting.
Motor issue.
Clean fan blades and housing (see Maintenance).
Ensure fan housing is securely mounted.
If noise persists, contact customer support.
Humidity sensor not responding correctly.Sensor malfunction or wiring issue.Verify wiring to the sensor. If issues persist, the sensor may need replacement. Contact customer support.

Warranty and Support

The Air King AK80H bath fan comes with a 5-year limited warranty. This warranty covers defects in materials and workmanship under normal use.

For warranty claims, technical assistance, or replacement parts, please contact Air King customer support. Keep your proof of purchase for warranty validation.

Manufacturer: Air King America

Related Documents - AK80H

Preview Air King Indoor Air Quality Product Catalog: Exhaust Fans, Heaters & Ventilation Solutions
Explore the comprehensive Air King product catalog featuring ENERGY STAR certified exhaust fans, combination heaters, and fresh air systems designed to enhance indoor air quality and meet ASHRAE 62.2 standards. Find detailed specifications and solutions for residential and commercial ventilation needs.
Preview Air King DH55 Dehumidistat Operating Manual and Installation Instructions
Comprehensive operating and installation guide for the Air King DH55 Dehumidistat, covering safety precautions, electrical specifications, wiring diagrams, operational instructions, and limited warranty information.
Preview Air King SEV28S Power Pack Ventilation Hood Specifications and Installation Guide
Detailed specifications, installation instructions, operation, maintenance, and troubleshooting for the Air King SEV28S Power Pack ventilation hood. Includes product dimensions, performance data, safety warnings, and warranty information.
Preview Air King AK100L/AK100FL Exhaust Fan with Light - Installation and Operating Manual
This manual provides essential instructions for installing, operating, and maintaining the Air King AK100L and AK100FL exhaust fan with light. It includes safety precautions, troubleshooting tips, warranty information, and a parts diagram.
Preview Air King Exhaust Fan Installation and Operation Manual
Comprehensive guide for installing, operating, and maintaining Air King exhaust fans, including safety information, troubleshooting, and warranty details for models AS50, AS60, AS70, and AS54.
Preview Air King AK100D/AK100DH Exhaust Fan Installation and Operating Manual
Comprehensive installation, operation, troubleshooting, and warranty guide for the Air King AK100D and AK100DH exhaust fans. Includes safety precautions, wiring diagrams, and parts list.