1. Introduction
This instruction manual provides essential information for the safe and proper installation, operation, and maintenance of the Eaton 150A Main Breaker Load Center. Please read this manual thoroughly before proceeding with any installation or operation to ensure personal safety and optimal product performance. Retain this manual for future reference.
2. Safety Information
WARNING: Risk of electric shock or electrocution. Installation and servicing of this electrical equipment must be performed by qualified personnel only. Always disconnect power at the main service panel before working on or near electrical equipment.
- Always follow local and national electrical codes.
- Ensure all power is OFF before beginning any work. Verify with a voltage tester.
- Use appropriate personal protective equipment (PPE), including insulated gloves and safety glasses.
- Do not install or operate this product if it appears damaged.
- Never bypass or modify safety features.
3. Product Overview
The Eaton 150A Main Breaker Load Center is designed for residential and light commercial applications to provide centralized control and protection for electrical circuits. It houses a 150 Amp main circuit breaker and multiple branch circuit breaker positions, distributing power safely throughout a property.

Figure 1: Eaton 150A Main Breaker Load Center. This image displays the Eaton 150A Main Breaker Load Center. The gray metal enclosure is shown with its front door open, revealing the internal bus bars and multiple slots for individual circuit breakers. A main breaker is visible at the top, along with warning labels and a small digital display or indicator.
4. Setup and Installation
Installation of the Eaton 150A Main Breaker Load Center requires adherence to all applicable electrical codes and safety standards. It is strongly recommended that installation be performed by a licensed electrician.
4.1 Pre-Installation Checks
- Verify that the load center rating (150A) matches the service entrance requirements.
- Ensure adequate space for installation, ventilation, and future access.
- Confirm all necessary tools and materials are available.
4.2 Mounting the Load Center
- Choose a suitable, dry location for mounting, free from obstructions.
- Securely mount the load center enclosure to a sturdy surface using appropriate fasteners.
- Ensure the enclosure is level and plumb.
4.3 Wiring Connections
- Route service entrance conductors into the load center, ensuring proper strain relief.
- Connect the main service conductors to the main breaker terminals.
- Connect the neutral conductor to the neutral bus bar and the grounding conductor to the ground bus bar.
- Install branch circuit breakers into the appropriate slots and connect branch circuit wiring.
- Ensure all connections are tight and secure.
5. Operation
Operating the Eaton 150A Main Breaker Load Center involves managing the main breaker and individual branch circuit breakers.
5.1 Main Breaker Operation
- To turn power ON to the entire load center, push the main breaker handle firmly to the 'ON' position.
- To turn power OFF to the entire load center, push the main breaker handle firmly to the 'OFF' position.
5.2 Branch Circuit Breaker Operation
- Individual branch circuit breakers control power to specific circuits.
- To turn a circuit ON, push the breaker handle to the 'ON' position.
- To turn a circuit OFF, push the breaker handle to the 'OFF' position.
- If a breaker trips (moves to a middle or 'OFF' position), it indicates an overload or short circuit. To reset, first move the handle fully to 'OFF', then to 'ON'. If it trips again, investigate the cause of the fault.
6. Maintenance
Regular maintenance helps ensure the longevity and safe operation of your Eaton Load Center. Always disconnect power before performing any maintenance.
- Annual Inspection: Have a qualified electrician inspect the load center annually for loose connections, signs of overheating, corrosion, or damage.
- Cleaning: Keep the area around the load center clear of obstructions. If necessary, gently clean the exterior with a dry cloth. Do not use liquids or abrasive cleaners.
- Tighten Connections: Periodically, an electrician should check and tighten all electrical connections to prevent arcing and overheating.
7. Troubleshooting
This section addresses common issues you might encounter with your load center.
7.1 Circuit Breaker Trips Repeatedly
- Cause: Overload on the circuit, short circuit, or ground fault.
- Solution: Disconnect some appliances or devices from the circuit. If the breaker still trips, there may be a short circuit or ground fault in the wiring or an appliance. Consult a qualified electrician.
7.2 No Power to Entire House/Area
- Cause: Main breaker tripped, power outage from utility.
- Solution: Check the main breaker in the load center. If tripped, reset it (OFF then ON). If it immediately trips again, contact an electrician. Check with your utility company for local power outages.
7.3 Flickering Lights
- Cause: Loose connection, overloaded circuit, or utility issue.
- Solution: Check for loose connections at outlets or switches. Reduce load on the circuit. If the problem persists, contact an electrician or your utility provider.
8. Specifications
| Brand | Eaton |
| Model | 150A Main Breaker Load Center |
| Main Breaker Current Rating | 150 Amps |
| Product Dimensions | 15.8 x 5.5 x 5.5 inches |
| Product Weight | 42.5 Pounds |
| Manufacturer | EATON |
| ASIN | B008KMXFMK |
| UPC | 782113098098 |
9. Warranty and Support
For specific warranty information regarding your Eaton 150A Main Breaker Load Center, please refer to the documentation provided with your purchase or visit the official Eaton website. For technical support, service, or inquiries, please contact Eaton customer service directly.
Eaton Customer Support: Refer to the contact information on the official Eaton website or product packaging.