Pentair EC-520555
Contents
Pentair IntelliChlor Salt Cell Chlorine Generator User Manual
Model: EC-520555 | Brand: Pentair
Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Pentair IntelliChlor Salt Cell Chlorine Generator. This device is designed to automatically produce chlorine from salt in your pool water, providing a continuous supply of pure chlorine for a clean and clear swimming environment. It offers an alternative to traditional chlorine handling, reducing the need to buy, carry, store, and handle chlorine products.

Figure 1: Pentair IntelliChlor Salt Cell Chlorine Generator (Model EC-520555)
Safety Information
WARNING: Risk of Electric Shock.
- Install properly.
- Ensure proper grounding and avoid water contact during operation.
- Always switch off main power before connecting or disconnecting the IntelliChlor cell.
Setup and Installation
Follow these steps for proper installation of your IntelliChlor Salt Cell Chlorine Generator:
- Preparation: Ensure the pool pump is turned off and the main power to the pool system is disconnected. Close any necessary valves to prevent water flow through the cell location.
- Physical Installation: Install the Pentair IntelliChlor IC40 Salt Cell Chlorine Generator with the Pentair IntelliChlor IC20 Chlorine Generator system. The unit is designed for easy integration into existing pool plumbing.
- Electrical Connection: Connect the cell to the control panel. Ensure all connections are secure and watertight.
- Water Flow: Once installed, ensure proper water flow through the cell. The unit includes a flow sensor to detect adequate water movement.
- Salt Level Adjustment: Set the recommended salt level between 3500 - 4000 PPM (Parts Per Million). Refer to your pool's specific requirements and test the water accurately.

Figure 2: Internal flow and connections of the IntelliChlor cell.
Video 1: Overview of the Salt Chlorine Generator, demonstrating its compact design and integration into a pool system. This video is provided by Shasta Pool Supply.
Operating Instructions
The IntelliChlor system is designed for user-friendly operation with clear indicators.
- Power On: Once installed and plumbed, restore power to the pool system. The IntelliChlor unit will power on and begin its diagnostic checks.
- Monitoring Salt Level: The unit features easy-to-view displays that enable fast checking of salt levels. The "Salt Level" indicator lights (Good, Low, Red) provide real-time feedback. Ideal salt is 3600 PPM.
- Sanitizer Output Adjustment: Use the push-button operation to adjust the chlorine output. The "Sanitizer Output" LEDs (Min, 25%, 50%, 75%, Max) indicate the current production level.
- Boost Mode: Press the "Boost On/Off" button for a 24-hour 100% output cycle when extra sanitization is needed.
- Automatic Shut-off: The unit includes an automatic shut-off feature that protects the unit and prolongs cell life under low-water-temperature conditions.

Figure 3: The IntelliChlor control panel showing salt level, status, and sanitizer output indicators.
Maintenance
Regular maintenance ensures optimal performance and longevity of your IntelliChlor cell.
- Cell Cleaning: Inspect and clean the cell every three months as needed. The "Acid Clean Every 3 Months" indicator will illuminate as a reminder. Calcium buildup can reduce efficiency.
- Cell-Life Tracking: The unit provides full diagnostic capabilities, including cell-life tracking that communicates remaining hours of cell life in real-time.
- Water Chemistry: Regularly test and maintain proper pool water chemistry, including pH, alkalinity, and stabilizer levels, to support efficient chlorine production and cell health.
Troubleshooting
This section addresses common issues you might encounter with your IntelliChlor Salt Cell Chlorine Generator.
| Problem | Possible Cause | Solution |
|---|---|---|
| Low Chlorine Output | Low salt level, dirty cell, low water temperature, low flow, or worn-out cell. | Test pool water salt level with a reliable test kit. If low, add salt according to instructions. Clean the cell if calcium buildup is visible. Ensure water temperature is above 52°F (11°C). Verify adequate water flow. If cell life is depleted, replace the cell. |
| "Low Salt" Indicator On | Actual low salt level, or sensor issue. | Test pool water salt level with a reliable test kit. If low, add salt according to instructions. If salt is adequate, inspect cell and connections. |
| "No Flow" Indicator On | Insufficient water flow through the cell. | Check pool pump operation, filter cleanliness, and ensure all valves are open allowing proper flow to the cell. |
| "Inspect Cell" Indicator On | Cell requires cleaning or is nearing end of life. | Perform an acid wash cleaning of the cell. If the issue persists after cleaning, the cell may need replacement. |
Specifications
- Brand: Pentair
- Model Number: EC-520555
- Item Weight: 8.4 pounds
- Product Dimensions: 17 x 6.5 x 6.5 inches
- UPC: 789610109289, 788379887537
- Sanitizes Pools Up To: 40,000 gallons
- Connections: 2" Union Connections
- Features: Full diagnostic capabilities, cell-life tracking, push-button operation, easy-to-view displays, automatic shut-off.
Warranty Information
The Pentair IntelliChlor Salt Cell Chlorine Generator includes a 2-year warranty from the date of purchase. For full warranty details and terms, please visit the manufacturer's official website or contact Pentair customer support.
Note: Warranty coverage may vary based on installation and product registration. Keep your proof of purchase.
Support and Contact
For technical assistance, troubleshooting, or to inquire about replacement parts, please contact Pentair customer support or visit their official website:
- Pentair Official Website: www.pentair.com
- Pentair Store on Amazon: Visit the Pentair Store