Vortice M10/4T

Vortice Record Extractor Fan M10/4T 100mm with Timer User Manual

Model: M10/4T (Part Number: 11630)

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Vortice Record Extractor Fan M10/4T 100mm with Timer. This unit is designed for intermittent or continuous ventilation in small to medium domestic or commercial premises, such as bathrooms, utility rooms, or kitchens. Please read these instructions thoroughly before installation and use, and retain them for future reference.

Vortice Record Extractor Fan M10/4T 100mm with Timer

Figure 1: Front view of the Vortice Record Extractor Fan M10/4T 100mm with Timer. This image displays the fan's white casing and central circular grille.

2. Safety Information

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Installation must be carried out by a qualified electrician in accordance with all local and national wiring regulations.
  • Always disconnect the power supply before performing any installation, maintenance, or cleaning.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Do not use this fan with any solid-state speed control device.
  • Ensure that the air discharge is not obstructed.
  • The fan must not be installed in areas where the ambient temperature exceeds 40°C (104°F).

3. Package Contents

Carefully unpack the product and check for any damage. If any components are missing or damaged, contact your retailer immediately.

  • Vortice Record Extractor Fan M10/4T unit
  • Instruction Manual
  • Mounting hardware (screws, wall plugs)
  • Power cord (may not be included depending on regional regulations or specific model variant)

4. Specifications

The following table outlines the key technical specifications for the Vortice Record Extractor Fan M10/4T 100mm with Timer.

FeatureSpecification
BrandVortice
Model NameM10/4T (11630)
Electric Fan DesignExhaust Fan
Power SourceElectrical Cable
Voltage240 Volts
Wattage16 Watts
Air Flow Capacity85 Cubic Meters Per Hour (approx. 50 CFM)
Noise Level39 Decibels
Blade Length100 Millimeters
Item Weight0.43 Kilograms (approx. 15.1 ounces)
Package Dimensions18.4 L x 7.6 H x 13.0 W (centimeters) / 7.6 x 5.39 x 3.23 (inches)
Installation TypeWall Mount
Room TypeBathroom
Special FeatureTimer Function
Control MethodTouch (likely referring to external switch)
Finish TypeMetallic
CertificationCE Approved
Vortice Record Extractor Fan M10/4T Energy Label

Figure 2: Technical data and energy label for the Vortice Record Extractor Fan. Key data points include a maximum flow rate of 82 m³/h, total electrical power consumption of 14.3 W at maximum flow, and a sound power level (LWA) of 51 dB(A).

5. Installation

Installation should only be performed by a qualified professional to ensure compliance with electrical safety standards and optimal performance.

5.1. Choosing a Location

Select a suitable wall-mount location, typically in a bathroom or utility area, ensuring adequate space for the fan and ducting. Avoid locations directly above heat sources or where the fan might be exposed to direct water spray.

Vortice Extractor Fan installed in a kitchen

Figure 3: Example of a Vortice extractor fan installed on a wall in a room, demonstrating typical placement for ventilation.

5.2. Mounting and Wiring

  1. Prepare the Opening: Create an appropriate opening in the wall for the fan's ducting, typically 100mm in diameter. Refer to the dimensional drawing for precise measurements.
  2. Secure the Fan: Mount the fan unit securely to the wall using the provided mounting hardware. Ensure it is level and stable.
  3. Electrical Connection: Connect the fan to the main electrical supply. The M10/4T model includes a timer function, which requires specific wiring to a switched live and permanent live supply. Consult the wiring diagram provided with the product packaging or a qualified electrician for correct connection.
  4. Ducting: Connect appropriate ducting to the fan's outlet to direct extracted air outdoors. Ensure all connections are sealed to prevent air leakage.
Vortice Extractor Fan Dimensional Drawing

Figure 4: Technical drawing illustrating the dimensions of the Vortice Extractor Fan, including overall width (A), height (B), depth (C), and duct diameter (E, F).

6. Operation

The Vortice Record Extractor Fan M10/4T is designed for simple operation, typically controlled via an external light switch or a dedicated fan switch.

6.1. Basic On/Off

When connected to a light switch, the fan will activate when the light is turned on. When connected to a dedicated fan switch, simply toggle the switch to turn the fan on or off.

6.2. Timer Function

The M10/4T model features an adjustable timer. After the fan is switched off (e.g., by turning off the light), the fan will continue to operate for a preset duration before automatically shutting down. This duration can typically be adjusted using a small potentiometer located within the fan unit (access usually requires removing the front cover and disconnecting power). Experiment with the timer setting to achieve the desired run-on time for effective ventilation.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your extractor fan. Always disconnect the power supply before any maintenance.

7.1. Cleaning the Exterior

Wipe the exterior of the fan with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the finish.

7.2. Cleaning the Fan Blades

Periodically, dust and debris may accumulate on the fan blades, reducing efficiency. To clean:

  1. Disconnect Power: Ensure the fan's power supply is completely disconnected at the circuit breaker.
  2. Remove Cover: Carefully remove the front grille or cover of the fan.
  3. Clean Blades: Gently clean the fan blades and surrounding areas with a soft brush or a vacuum cleaner with a brush attachment. Avoid bending the blades.
  4. Reassemble: Once clean, reattach the cover securely.
Vortice Extractor Fan Internal View

Figure 5: Internal view of the Vortice Extractor Fan, showing the fan blades and motor housing, which may require periodic cleaning.

8. Troubleshooting

If you encounter issues with your Vortice Extractor Fan, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Fan does not turn onNo power supply
Faulty wiring
Internal fault
Check circuit breaker and wall switch. Ensure correct wiring (consult electrician). If problem persists, contact support.
Fan is excessively noisyLoose mounting
Obstruction in fan blades
Motor issue
Ensure fan is securely mounted. Disconnect power and check for obstructions. If noise persists, contact support.
Insufficient air extractionBlocked ducting
Dirty fan blades
Incorrect fan size for room
Check ducting for blockages. Clean fan blades as per maintenance section. Ensure fan is appropriately sized for the room volume.
Timer not working correctlyIncorrect timer setting
Wiring issue
Adjust the timer potentiometer. Verify timer wiring with an electrician.

For issues not listed here or if solutions do not resolve the problem, please contact qualified technical support.

9. Warranty and Support

9.1. Warranty Information

Please refer to the warranty card or documentation included with your purchase for specific warranty terms and conditions. Keep your proof of purchase for any warranty claims.

9.2. Customer Support

For technical assistance, spare parts, or service, please contact your retailer or visit the official Vortice website for support contact information.

Related Documents - M10/4T

Preview Vortice Quadro Medio - Manuale di Istruzioni
Manuale completo per l'installazione, l'uso e la manutenzione del ventilatore Vortice Quadro Medio. Include dettagli sui modelli, collegamenti elettrici, impostazioni del timer e avvertenze di sicurezza.
Preview Manuale di Istruzioni Vortice Punto: Modelli M 90, M 100, M 120, M 150
Manuale completo per l'installazione, l'uso e la manutenzione degli aspiratori Vortice Punto, con dettagli sui modelli M 90, M 100, M 120, M 150 e M 100 12V. Include avvertenze di sicurezza e specifiche tecniche.
Preview Vortice VORT QUADRO MEDIO - Manuale di Istruzioni
Manuale di istruzioni completo per l'aspiratore centrifugo Vortice VORT QUADRO MEDIO, che include dettagli su installazione, funzionamento, modelli, manutenzione e avvertenze di sicurezza.
Preview Punto Vortice - Manuale di Istruzioni e Modelli
Manuale di istruzioni per l'aspiratore elicoidale Punto Vortice, inclusi dettagli sui modelli M 90, M 100, M 120, M 150 e M 100 12V. Contiene informazioni su installazione, manutenzione e sicurezza.
Preview Vort Max ES Centrifugal Aspirator: Installation and User Manual
Comprehensive instruction manual for the Vortice Vort Max ES wall-mounted centrifugal aspirator, covering product description, compliance, safety warnings, installation, maintenance, wiring diagrams, and disposal.
Preview Vortice VORT QUADRO SUPER: Manuale di Istruzioni e Guida Utente
Guida completa all'installazione, uso e manutenzione del ventilatore centrifugo Vortice VORT QUADRO SUPER. Scopri le funzionalità, le avvertenze di sicurezza e le procedure per garantire prestazioni ottimali e lunga durata.