1. Introduction

The Claber Programmable Solenoid Valve with Programmer is an advanced device designed to automate irrigation systems. It can be installed directly on a water outlet or tap, and its robust, leak-proof design (IP68 rated) allows it to function even when fully immersed. The integrated programmer offers flexible scheduling with up to 6 daily programs, controlled via a user-friendly three-button interface and a large display.

This manual provides detailed instructions for the proper installation, operation, and maintenance of your Claber Solenoid Valve to ensure optimal performance and longevity.

Claber Programmable Solenoid Valve

Figure 1: Claber Programmable Solenoid Valve with Programmer. This image shows the main unit of the solenoid valve, featuring the integrated digital programmer on top and the water inlet/outlet connections at the bottom.

2. Safety Information

Please read all safety instructions carefully before installing and operating the device. Failure to follow these instructions may result in damage to the product or personal injury.

  • Do not allow children to operate this device. This product is not suitable for use by children.
  • Avoid animal interaction. Keep the device away from animals to prevent damage or interference with operation.
  • Ensure the operating pressure is within the specified range of 0.5 to 12 bar.
  • Use only a 9V alkaline battery as specified.
  • Do not attempt to disassemble or repair the unit beyond the instructions provided in this manual.
  • When installing underground, ensure proper drainage and protection from physical damage.

3. Product Components

The Claber Programmable Solenoid Valve consists of the following main components:

  • Solenoid Valve Unit: The main body with 1-inch F (26-34 mm) input and outlet threads.
  • Integrated Programmer: Digital display and three control buttons for setting irrigation schedules.
  • Battery Compartment: Located beneath the programmer, designed for a 9V alkaline battery (not included).
  • Leak-proof Lid (IP68): Protects the electronic components from water ingress.

4. Setup and Installation

4.1. Battery Installation

The programmer requires one 9V alkaline battery (not included) for operation. A fresh battery is typically sufficient for an entire season.

  1. Gently unscrew and remove the top programmer unit from the valve body by turning it counter-clockwise.
  2. Locate the battery compartment on the underside of the programmer unit.
  3. Insert a new 9V alkaline battery, ensuring correct polarity.
  4. Carefully reattach the programmer unit to the valve body, aligning the threads and turning clockwise until secure. Ensure the seal is properly seated to maintain IP68 rating.
Battery Installation Diagram

Figure 2: Battery Installation. This diagram illustrates the steps for removing the programmer unit, inserting the 9V battery into its compartment, and reattaching the unit to the valve body.

4.2. Physical Installation

The solenoid valve can be installed directly onto a tap or a water outlet. It can be mounted vertically or horizontally. Ensure the flow direction indicated on the valve body (marked 'FLOW') matches the water flow.

  • Above Ground Installation: Connect the 1-inch F (26-34 mm) input thread to your water source and the output thread to your irrigation line. Hand-tighten or use a wrench gently to ensure a leak-free connection.
  • Underground Installation: The valve is IP68 rated and can be installed in a cockpit or valve box for protection. Ensure the valve is placed on a bed of gravel for drainage and that the valve box allows for easy access for maintenance.
Underground Installation Example

Figure 3: Example of Underground Installation. This image depicts the Claber solenoid valve installed underground within a valve box, connected to an irrigation line, demonstrating a typical setup for a hidden system.

Connection Diagram

Figure 4: Connection Diagram. This image shows a schematic of the solenoid valve connected in an irrigation system, illustrating the input and output connections and the direction of water flow.

5. Operating Instructions

The Claber programmer is designed for easy operation with three control buttons and a clear display.

5.1. Basic Programming

The programmer allows for setting watering times from 1 minute up to 23 hours and 59 minutes, with the possibility of up to 6 watering cycles per day. It supports both manual and weekly programming, with options to exclude specific days of the week.

  • Display: The large format display communicates all necessary information using symbols and numbers.
  • Buttons: Use the three buttons (typically 'Mode', 'Up', 'Down' or similar) to navigate through menus and adjust settings.
  • Setting Time and Day: Before programming, ensure the current time and day are correctly set on the programmer.
  • Creating Programs: Follow the on-screen prompts to set start times, duration, and frequency for each of the up to 6 daily programs.
  • Manual Watering: The unit typically includes a manual override function for immediate watering outside of scheduled programs. Consult the on-screen menu for this option.

6. Maintenance

6.1. Battery Replacement

Replace the 9V alkaline battery annually or when the low battery indicator appears on the display. Refer to Section 4.1 for detailed battery installation instructions.

6.2. Winterization and Storage

During winter months or periods of freezing temperatures, it is recommended to remove the programmer unit and store it in a sheltered, frost-free location. The electronic components are separable from the plumbing for convenient removal and storage.

  • Turn off the main water supply to the valve.
  • Drain any remaining water from the valve and irrigation lines.
  • Unscrew and remove the programmer unit from the valve body.
  • Store the programmer in a dry, protected area where temperatures do not drop below +5 °C.
  • If the valve body remains installed, ensure it is completely drained and protected from freezing.

6.3. Cleaning

Periodically clean the exterior of the valve and programmer with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the display and buttons are free from dirt and debris for clear visibility and proper function.

7. Troubleshooting

If you encounter issues with your Claber Programmable Solenoid Valve, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Programmer display is blank or dim.Low or dead battery.Replace the 9V alkaline battery.
Valve does not open/close as programmed.Incorrect programming; Low battery; Water pressure too low/high; Debris in valve.Verify program settings; Replace battery; Check water pressure (0.5-12 bar); Inspect valve for obstructions.
Water leakage from connections.Loose connections; Damaged O-rings/seals.Tighten connections; Inspect and replace O-rings/seals if damaged.
Valve not responding to button presses.Battery issue; Electronic malfunction.Replace battery. If problem persists, contact customer support.

If the issue persists after attempting these solutions, please contact Claber customer support for further assistance.

8. Specifications

FeatureSpecification
Model NumberCL0000908260000
MaterialPA6
Dimensions (L x W x H)7.48 x 4.33 x 7.68 inches (180x105x190 cm)
Number of Ports2
Valve TypeSolenoid Valve
Input/Output Thread1 inch F (26-34 mm)
Voltage9 Volts (DC)
Battery Type9V Alkaline (not included)
Operating Pressure0.5 to 12 bar
Flow Rate4.6 to 96 litres/minute
Operating Temperature+5 °C to +70 °C
Protection RatingIP68 (leak-proof, works in total immersion)
Programming CyclesUp to 6 daily programs
Watering Duration1 minute to 23 hours 59 minutes

9. Warranty and Support

9.1. Warranty Information

For detailed warranty information regarding your Claber Programmable Solenoid Valve, please refer to the warranty card included with your product or visit the official Claber website. Keep your proof of purchase for warranty claims.

9.2. Customer Support

If you require further assistance, have questions about installation, programming, or troubleshooting that are not covered in this manual, please contact Claber customer support. Contact details can typically be found on the official Claber website or on the product packaging.

Related Documents - CL0000908260000

Preview Claber Elettra Programmable Solenoid Valve User Manual
Comprehensive guide to installing, operating, and maintaining the Claber Elettra programmable solenoid valve. Includes instructions for battery installation, time setting, programming irrigation cycles, weekly programming, manual operation, program deletion, and system reset.
Preview Claber Dual Select 8488 Irrigation Timer - User Manual & Guide
Comprehensive user manual for the Claber Dual Select 8488 automatic irrigation timer. Learn about installation, programming, features, maintenance, and troubleshooting for your garden watering system.
Preview Claber RAIN SENSOR RF 90831 - User Manual and Installation Guide
Comprehensive guide for the Claber RAIN SENSOR RF (model 90831), detailing installation, component identification, battery replacement, and compatibility with Claber irrigation systems.
Preview Manuale Utente Claber Aqua-Magic System 8063
Guida all'installazione, configurazione e utilizzo del Claber Aqua-Magic System, un kit automatico a goccia alimentato a energia solare per giardini e vasi.
Preview Claber Idris Spike User Manual and Plant Watering Guide
Detailed instructions and recommendations for using the Claber Idris Spike, a self-watering device for potted plants. Covers setup, maintenance, and plant-specific watering needs.
Preview Claber Multipla DC 9V LCD Automatic Irrigation Timer
User manual and installation guide for the Claber Multipla DC 9V LCD automatic irrigation timer (Model 8060). Learn how to install, program, operate, and troubleshoot your automatic garden watering system.