Mastercool 67010

Mastercool 67010 30 lb Refrigerant Recovery Cylinder User Manual

Model: 67010 | Brand: Mastercool

1. Introduction

This manual provides essential information for the safe and effective use of your Mastercool 67010 30 lb Refrigerant Recovery Cylinder. This cylinder is designed for the storage and transport of recovered refrigerant gases, featuring a durable HP295 steel construction and a built-in float switch for 80% automatic shutoff. Please read this manual thoroughly before operating the cylinder to ensure proper handling, maintenance, and safety.

2. Safety Information

WARNING: Improper use of this recovery cylinder can lead to serious injury or death. Always follow all safety guidelines and local regulations.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling refrigerants and the recovery cylinder.
  • Ensure the cylinder is placed on a stable, level surface during use and transport.
  • Do not overfill the cylinder. The built-in float switch provides an 80% fill shutoff, but always monitor the weight during recovery.
  • This cylinder is NOT FOR USE WITH NITROGEN.
  • Ensure all connections are secure and leak-free before operating.
  • Store the cylinder in a cool, dry, well-ventilated area, away from direct sunlight and heat sources.
  • Transport the cylinder upright and secured to prevent tipping.
  • Only use this cylinder for its intended purpose: the recovery and storage of refrigerants.
  • Regularly inspect the cylinder for any signs of damage, corrosion, or leaks. Do not use a damaged cylinder.

3. Product Features

The Mastercool 67010 Refrigerant Recovery Cylinder is engineered with several features to ensure efficient and safe refrigerant handling:

  • Durable Construction: Made from HP295 steel with a powder-coated finish for high gloss, corrosion resistance, and long-lasting durability.
  • Float Switch: Equipped with a built-in float switch for 80% automatic shutoff, preventing overfilling.
  • Y-Valve Design: Features a Y-valve for separate control of liquid and vapor recovery, enhancing efficiency and safety.
  • Secure Connections: Includes 1/2" ACME fittings for reliable and secure hose connections.
  • DOT-Approved: Conforms to DOT-4BA400 specifications and ARI guidelines, ensuring safe transport and use. TC Canadian approved.
  • Pre-charged Interior: Cylinder is pre-charged to provide a clean, dry interior upon receipt.
  • Wide Compatibility: Compatible with all types of refrigerants, including CFCs, HFCs, HCFCs, and blends (e.g., R12, R22, R134a, R410A).
  • UL Listed Valves: Valve and float switch are UL listed.
Mastercool 67010 30 lb Refrigerant Recovery Cylinder

Image: The Mastercool 67010 30 lb Refrigerant Recovery Cylinder, showing its blue powder-coated finish and valve assembly.

Mastercool 67010 Cylinder Dimensions

Image: Diagram illustrating the dimensions of the Mastercool 67010 cylinder (9.125" width x 17.52" height) and its 30 lb capacity with built-in float switch.

Mastercool 67010 Y-Valve and ACME Fittings

Image: Close-up view of the Y-valve design and 1/2" ACME fittings, highlighting the large, easy-grip knobs for secure connections.

Mastercool 67010 Powder-Coated Finish and Base

Image: Details of the powder-coated finish, roll core base, and collar style handle, emphasizing the cylinder's durable construction.

Mastercool 67010 Refrigerant Compatibility

Image: The recovery cylinder connected to a recovery machine, illustrating its compatibility with various refrigerants like R12, R22, R134a, and R410A.

Mastercool 67010 Certifications

Image: A stack of Mastercool cylinders, highlighting their compliance with DOT-4BA400 and Transport Canada standards for safe transport.

4. Specifications

AttributeValue
Model67010
Size (W x H)9.125" x 17.52"
Tare Weight17.99 lb. (approx. 19 pounds item weight)
Standard SpecificationDOT-4BA400
Nominal Water Capacity26.2 lb. / 11.9 L
Service Pressure400 PSI / 2.7 MPa
Tank Test Pressure800 PSI / 5.5 MPa
Relief Valve Pressure600 PSI / 4.1 MPa
Air Tightness Pressure400 PSI / 2.7 MPa
Body MaterialHP295 Steel
Connections1/2" ACME
Float Switch Opening3/4" NPT (accepts 80% fill float switch shut-off device)
Air Purge Valve Opening1/4"

5. Setup

Before first use, ensure the cylinder is inspected for any shipping damage. Although pre-charged with dry air, it is recommended to evacuate the cylinder to a deep vacuum before introducing refrigerant to ensure a clean, dry interior and prevent contamination.

  1. Visual Inspection: Check the cylinder for any dents, corrosion, or damage to the valves and connections. Do not use if damaged.
  2. Valve Check: Ensure both the liquid and vapor valves (Y-valve) operate smoothly and seal completely when closed.
  3. Vacuum Evacuation:
    • Connect a vacuum pump to one of the cylinder's service ports using appropriate hoses.
    • Open the cylinder valve(s) to allow evacuation.
    • Run the vacuum pump until a deep vacuum (e.g., 500 microns or less) is achieved.
    • Close the cylinder valve(s) and shut off the vacuum pump. Monitor the vacuum gauge for any rise, indicating a leak. If a leak is detected, identify and resolve it before proceeding.
  4. Placement: Position the cylinder upright on a stable, level surface in a well-ventilated area, away from heat sources or direct sunlight.

6. Operating Instructions

This section outlines the general procedure for recovering refrigerant into the Mastercool 67010 cylinder. Always refer to your recovery machine's manual for specific operating instructions.

  1. Connect Hoses:
    • Connect the appropriate hose from your recovery machine's output to the vapor port of the recovery cylinder.
    • If recovering liquid, connect another hose from the recovery machine's liquid output to the liquid port of the cylinder.
    • Ensure all connections are tight and secure.
  2. Purge Hoses: Before opening the cylinder valves, purge the hoses and recovery machine of any air or non-condensables according to your recovery machine's instructions.
  3. Open Cylinder Valves: Slowly open the vapor valve (and liquid valve if recovering liquid) on the recovery cylinder.
  4. Start Recovery: Initiate the recovery process on your recovery machine.
  5. Monitor Fill Level: The built-in float switch will automatically shut off the recovery machine when the cylinder reaches 80% capacity. It is also recommended to use a refrigerant scale to monitor the weight and prevent overfilling.
  6. Complete Recovery: Once recovery is complete and the float switch has activated, or the desired weight is reached, close the cylinder valves.
  7. Disconnect: Safely disconnect the hoses from the cylinder and recovery machine.

Note: Always ensure the refrigerant type being recovered matches the intended use for the cylinder to prevent cross-contamination.

7. Maintenance

Proper maintenance ensures the longevity and safe operation of your Mastercool 67010 recovery cylinder.

  • Regular Inspection: Periodically inspect the cylinder for external damage, rust, or signs of leaks, especially around the valves and connections.
  • Valve Care: Keep the valve connections clean and free of debris. If valves become stiff, a small amount of appropriate lubricant may be applied, but consult a professional if issues persist.
  • Storage: When not in use, store the cylinder with valves closed and protective caps in place (if applicable). Store in a cool, dry, well-ventilated area.
  • Hydrostatic Testing: Recovery cylinders require periodic hydrostatic testing as mandated by DOT regulations. The retest date is stamped on the cylinder. Ensure the cylinder is retested by a certified facility before its retest date expires. Using an expired cylinder is unsafe and illegal.
  • Cleaning: Clean the exterior of the cylinder with a damp cloth. Avoid harsh chemicals that could damage the paint or markings.

8. Troubleshooting

This section addresses common issues you might encounter with your recovery cylinder.

ProblemPossible CauseSolution
Cylinder not filling / Slow filling
  • Valves not fully open
  • Hoses kinked or restricted
  • Recovery machine issue
  • Cylinder already full (80% shutoff activated)
  • Excessive non-condensables in system/cylinder
  • Ensure valves are fully open.
  • Check hoses for kinks or blockages.
  • Refer to your recovery machine's manual.
  • Check cylinder weight; if full, use another cylinder.
  • Evacuate cylinder to remove non-condensables.
Leak detected around valves/connections
  • Loose connections
  • Damaged O-rings/seals
  • Damaged valve stem
  • Tighten all connections.
  • Replace worn or damaged O-rings/seals.
  • If valve stem is damaged, cylinder may need professional repair or replacement.
Float switch not activating
  • Faulty float switch
  • Cylinder not upright
  • Ensure cylinder is upright.
  • If suspected faulty, rely on a refrigerant scale for fill level and contact Mastercool support.

For issues not listed here, or if troubleshooting steps do not resolve the problem, please contact Mastercool customer support.

9. Warranty and Support

Mastercool products are manufactured to high-quality standards. For specific warranty information regarding your 67010 Refrigerant Recovery Cylinder, please refer to the warranty card included with your purchase or visit the official Mastercool website. Mastercool has been a leading provider of professional quality air conditioning service tools and equipment for over four decades, committed to innovation and quality.

For technical support, parts, or service inquiries, please contact Mastercool customer service through their official website or the contact information provided in your product packaging.

Mastercool products are made/assembled in the USA, with all products checked and tested directly at Mastercool headquarters in Randolph, New Jersey, USA.

© 2024 Mastercool Inc. All rights reserved.

This manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.