Autotrol 1242470

Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve User Manual

Introduction

This manual provides essential information for the installation, operation, and maintenance of your Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve. Please read these instructions carefully before proceeding to ensure proper function and longevity of the unit.

Safety Information

Always observe basic safety precautions when installing or servicing the water softener control valve. Disconnect power before performing any maintenance. Ensure all plumbing connections are secure to prevent leaks. If you are unsure about any step, consult a qualified professional.

Product Overview

The Autotrol 1242470 is a robust 268/760 12V 5 Cycle Logix Control Valve designed for efficient water softening systems. It features durable construction with stainless steel and brass components, ensuring long-lasting performance. The 5 Cycle Logix Control provides precise operation for optimal water treatment.

Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve

Image: Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve. This image displays the main control valve unit, highlighting its compact design and connection points.

Setup and Installation

Proper installation is crucial for the optimal performance of your Autotrol control valve. Follow these general guidelines:

  1. Preparation: Ensure the water supply is turned off and depressurized before beginning installation.
  2. Mounting: Securely mount the control valve to the water softener tank. The valve is designed for a 2-inch Flange outlet.
  3. Plumbing Connections: Connect the inlet and outlet plumbing. The inlet features a National Pipe Tapered (NPT) connection. Ensure all connections are tight to prevent leaks.
  4. Drain Line: Connect the drain line to an appropriate drain, ensuring there is an air gap to prevent back-siphonage.
  5. Brine Line: Connect the brine line from the control valve to the brine tank.
  6. Electrical Connection: Connect the 12V power supply to the control valve. Ensure the power source matches the valve's requirements.
  7. System Startup: Slowly turn on the water supply, checking for leaks. Follow the operating instructions to program the control valve.

Note: The valve is constructed from durable stainless steel and brass, designed for longevity in water treatment applications.

Operating Instructions

The Autotrol 1242470 utilizes a 5 Cycle Logix Control system for efficient water softening. This section outlines basic operation:

  • Initial Programming: Upon first power-up or after a power outage, the control valve may require initial programming. Refer to the display and buttons to set the time of day, regeneration frequency, and other system parameters.
  • Regeneration Cycles: The 5 Cycle Logix Control manages the various stages of the regeneration process, including backwash, brine draw, slow rinse, fast rinse, and brine refill. These cycles are automatically initiated based on programmed settings or water usage.
  • Manual Regeneration: To initiate a manual regeneration cycle, typically press and hold a designated button on the control panel. Consult the control panel interface for specific instructions.
  • Display Information: The control panel display provides information such as current time, remaining capacity, and system status.

The 268/760 12V NO Cover Softener configuration ensures effective softening performance by precisely managing the flow and regeneration processes.

Maintenance

Regular maintenance helps ensure the long-term reliability and efficiency of your Autotrol control valve:

  • Salt Level Check: Periodically check the salt level in the brine tank. Ensure it is adequately filled with appropriate water softener salt.
  • Brine Tank Cleaning: Every few years, or if salt bridging occurs, clean the brine tank to remove any sediment or insoluble materials.
  • Injector Cleaning: If regeneration issues arise, the injector may need cleaning. Refer to detailed service instructions for this procedure.
  • System Inspection: Annually inspect all plumbing connections for leaks and check the overall condition of the valve and associated components.

Troubleshooting

This section addresses common issues you might encounter with your Autotrol control valve:

ProblemPossible CauseSolution
No soft waterLow salt level; Air in brine line; Clogged injector; Incorrect programmingAdd salt; Check brine line for air leaks; Clean injector; Verify programming settings
Continuous regenerationFaulty switch or sensor; Incorrect programmingInspect switches/sensors; Review and correct programming
Water leaks from valveLoose connections; Damaged O-rings or sealsTighten connections; Replace O-rings or seals
Error code on displaySpecific system malfunctionConsult the detailed service manual for specific error code interpretations and solutions.

Specifications

FeatureDetail
ManufacturerAutotrol
Part Number1242470
Item Model Number1242470
Item Weight6 pounds
Package Dimensions12 x 4 x 1.3 inches
Voltage12 Volts
Size2 inches
Inlet Connection TypeNational Pipe Tapered (NPT)
Outlet Connection TypeNPT
Outlet Connection Size2 Inches
Number of Ports268
Control Type5 Cycle Logix Control
Construction MaterialStainless Steel and Brass

Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Autotrol directly. Keep your purchase receipt as proof of purchase for warranty claims.

Manufacturer: Autotrol

© 2024 Autotrol. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.