Autotrol 1242470

Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve User Manual

Introduction

This manual provides essential information for the installation, operation, and maintenance of your Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve. Please read these instructions carefully before proceeding to ensure proper function and longevity of the unit.

Safety Information

Always observe basic safety precautions when installing or servicing the water softener control valve. Disconnect power before performing any maintenance. Ensure all plumbing connections are secure to prevent leaks. If you are unsure about any step, consult a qualified professional.

Product Overview

The Autotrol 1242470 is a robust 268/760 12V 5 Cycle Logix Control Valve designed for efficient water softening systems. It features durable construction with stainless steel and brass components, ensuring long-lasting performance. The 5 Cycle Logix Control provides precise operation for optimal water treatment.

Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve

Image: Autotrol 1242470 268/760 12V 5 Cycle Logix Control Valve. This image displays the main control valve unit, highlighting its compact design and connection points.

Setup and Installation

Proper installation is crucial for the optimal performance of your Autotrol control valve. Follow these general guidelines:

  1. Preparation: Ensure the water supply is turned off and depressurized before beginning installation.
  2. Mounting: Securely mount the control valve to the water softener tank. The valve is designed for a 2-inch Flange outlet.
  3. Plumbing Connections: Connect the inlet and outlet plumbing. The inlet features a National Pipe Tapered (NPT) connection. Ensure all connections are tight to prevent leaks.
  4. Drain Line: Connect the drain line to an appropriate drain, ensuring there is an air gap to prevent back-siphonage.
  5. Brine Line: Connect the brine line from the control valve to the brine tank.
  6. Electrical Connection: Connect the 12V power supply to the control valve. Ensure the power source matches the valve's requirements.
  7. System Startup: Slowly turn on the water supply, checking for leaks. Follow the operating instructions to program the control valve.

Note: The valve is constructed from durable stainless steel and brass, designed for longevity in water treatment applications.

Operating Instructions

The Autotrol 1242470 utilizes a 5 Cycle Logix Control system for efficient water softening. This section outlines basic operation:

The 268/760 12V NO Cover Softener configuration ensures effective softening performance by precisely managing the flow and regeneration processes.

Maintenance

Regular maintenance helps ensure the long-term reliability and efficiency of your Autotrol control valve:

Troubleshooting

This section addresses common issues you might encounter with your Autotrol control valve:

ProblemPossible CauseSolution
No soft waterLow salt level; Air in brine line; Clogged injector; Incorrect programmingAdd salt; Check brine line for air leaks; Clean injector; Verify programming settings
Continuous regenerationFaulty switch or sensor; Incorrect programmingInspect switches/sensors; Review and correct programming
Water leaks from valveLoose connections; Damaged O-rings or sealsTighten connections; Replace O-rings or seals
Error code on displaySpecific system malfunctionConsult the detailed service manual for specific error code interpretations and solutions.

Specifications

FeatureDetail
ManufacturerAutotrol
Part Number1242470
Item Model Number1242470
Item Weight6 pounds
Package Dimensions12 x 4 x 1.3 inches
Voltage12 Volts
Size2 inches
Inlet Connection TypeNational Pipe Tapered (NPT)
Outlet Connection TypeNPT
Outlet Connection Size2 Inches
Number of Ports268
Control Type5 Cycle Logix Control
Construction MaterialStainless Steel and Brass

Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Autotrol directly. Keep your purchase receipt as proof of purchase for warranty claims.

Manufacturer: Autotrol

Related Documents - 1242470

Preview Autotrol 255/760 Metered Water Softener Installation Guide
Comprehensive installation guide for the Autotrol 255/760 Metered Water Softener, covering setup, programming, and initial start-up procedures. Learn how to calculate hardness, tank size, and salt settings for optimal performance.
Preview Autotrol 268/760 Metered Water Softener Installation Guide
Step-by-step installation guide for the Autotrol 268/760 Metered Water Softener. Covers pre-installation, tank setup, valve installation, plumbing, brine tank connection, programming, and initial start-up. Includes essential programming values and troubleshooting tips.
Preview Pentair Autotrol 740/760 Control 255 & Performa Series Valves Service Manual
Service manual for Pentair Autotrol 740/760 Control 255 and Performa Series Valves (models 268, 268 FA). This guide covers installation, programming, system specifications, troubleshooting, maintenance, and assembly diagrams for water treatment systems.
Preview Autotrol Series 255 Valve / 440i Control: Installation, Operation and Maintenance Manual
Comprehensive guide for installing, operating, and maintaining the Autotrol Series 255 Valve and 440i Control water conditioning system. Covers features, installation steps, operation, troubleshooting, and maintenance.
Preview Autotrol Performa 263-268 Easy-iQ Installer Manual
Comprehensive installer manual for the Pentair Autotrol Performa 263-268 Easy-iQ water treatment control valve. This guide covers general information, safety, product description, system sizing, installation, programming, commissioning, operation, maintenance, troubleshooting, spare parts, and disposal.