Danner 40140

Supreme Hydro-Mag 2400 GPH Recirculating Water Pump User Manual

Model: 40140

Brand: Danner Manufacturing, Inc.

Supreme Hydro Logo

Introduction

The Danner Supreme Hydro-Mag 2400 GPH Recirculating Water Pump is engineered for efficient water circulation in various applications, including hydroponic systems, ponds, and fountains. This pump utilizes time-proven magnetic drive technology, ensuring energy-efficient and oil-free operation. It is designed for both in-line and submersible use, offering versatility and reliability.

Supreme Hydro-Mag 2400 GPH Water Pump, front view

Figure 1: Supreme Hydro-Mag 2400 GPH Water Pump, front view. This image shows the main body of the pump with its threaded outlet connection.

Safety Information

Setup

1. Unpacking

Carefully remove the pump and all accessories from the packaging. Inspect for any signs of damage during transit. Retain packaging for future storage or transport.

2. Installation Options: Submersible or Inline

The Supreme Hydro-Mag pump can be installed either fully submerged in water or as an inline pump outside the water source.

Supreme Hydro-Mag 2400 GPH Water Pump Side View

Figure 2: Side view of the Supreme Hydro-Mag pump, showing the inlet and outlet ports. This view helps in understanding plumbing connections for inline setup.

3. Connections

4. Venturi Adjustment (Applicable to Models 2-18)

For models that feature an adjustable Venturi, this mechanism allows for aeration of the water flow, which can stimulate root growth in hydroponic applications. Consult your specific model's documentation to determine if this feature is present and how to adjust it for optimal air intake.

Hydroponic plant roots in water

Figure 3: Image illustrating healthy hydroponic plant roots submerged in water. Proper aeration, which can be enhanced by the Venturi feature, contributes to such root development.

Operating Instructions

1. Initial Startup

Once the pump is installed and all connections are secure, connect the power cord to a suitable grounded electrical outlet. The pump should begin circulating water immediately. Monitor the flow to ensure it is consistent and free of air bubbles.

2. Flow Rate Considerations

The Supreme Hydro-Mag 2400 GPH pump has a maximum flow rate of 2400 Gallons Per Hour (GPH) and a maximum shut-off head of 17 feet. The actual flow rate will vary depending on the head height (vertical distance the water is lifted) and any restrictions in the plumbing system. Ensure the pump's capacity matches the requirements of your system for efficient nutrient distribution and coverage.

Person holding a hydroponic lettuce plant

Figure 4: A person holding a hydroponic lettuce plant, demonstrating the type of application this pump supports. Adequate water circulation is crucial for such systems.

3. Continuous Duty Operation

This pump is designed for continuous duty operation, meaning it can run constantly without needing to be turned off periodically. Its robust design and magnetic drive technology contribute to its long-term reliability.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your pump.

1. Cleaning the Impeller and Housing

Over time, debris and mineral deposits can accumulate around the impeller, reducing pump efficiency. To clean:

  1. Disconnect the pump from the power source.
  2. Remove the pump from the water or disconnect plumbing for inline setups.
  3. Carefully open the pump housing to access the impeller. Refer to the pump's diagram for specific disassembly instructions.
  4. Clean the impeller and the impeller chamber thoroughly with a soft brush and clean water. Remove any stringy algae, hair, or mineral buildup.
  5. Reassemble the pump, ensuring all seals are properly seated.
Supreme Hydro-Mag 2400 GPH Water Pump Back View

Figure 5: Back view of the Supreme Hydro-Mag pump, showing the screws that secure the pump housing. These screws typically need to be removed for impeller access during cleaning.

2. Oil-Free Design

The Supreme Hydro-Mag pump is designed to be oil-free, eliminating the need for lubrication and preventing potential contamination of your water system. There are no seals to wear out, contributing to its low maintenance requirements.

Troubleshooting

ProblemPossible CauseSolution
Pump does not run.No power; clogged impeller; damaged motor.Check power connection and circuit breaker. Disconnect power and clean impeller. If motor is damaged, contact customer support.
Reduced water flow.Clogged impeller or intake screen; kinked tubing; excessive head height.Clean impeller and intake screen. Check and straighten tubing. Ensure pump is suitable for the required head height.
Pump is noisy.Debris in impeller; pump running dry (inline); vibration.Disconnect power and clean impeller. Ensure pump is fully submerged or properly primed for inline use. Check for stable placement.
Pump stops intermittently.Overheating due to blockage or low water level; electrical issue.Check for blockages and ensure adequate water level. Verify electrical connections.

Specifications

FeatureDetail
Model Number40140
Maximum Flow Rate2400 GPH (Gallons Per Hour) / 40 GPM (Gallons Per Minute)
Maximum Lifting Height (Shut-off)17 Feet
Power Consumption237 Watts / 2.2 Amps
Inlet Connection1" FPT (Female Pipe Thread)
Outlet Connection1" MPT (Male Pipe Thread)
Power Cord Length10 Feet
Operation TypeSubmersible or Inline
MaterialAcrylonitrile Butadiene Styrene (ABS)
Dimensions (L x W x H)7.25 x 3.38 x 5.88 inches
Item Weight9.12 Pounds

Warranty

The Danner Supreme Hydro-Mag 2400 GPH Recirculating Water Pump comes with a 5-year limited warranty. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full warranty details and terms, refer to the official Danner Manufacturing, Inc. website or contact their customer service.

Support

For further assistance, technical support, or to inquire about replacement parts, please contact Danner Manufacturing, Inc. customer service or visit their official website:

You may also find additional resources and FAQs on their support pages.

Related Documents - 40140

Preview Danner Air Pumps AP-Series Care & Operating Instructions | Aquarium & Pond Use
Comprehensive care and operating instructions for Danner AP-Series air pumps, including models AP-20, AP-40, AP-60, and AP-100. Covers features, indoor and pond installation guidelines, and important safety precautions.
Preview Danner Pondmaster Magnetic Drive 2-7 Pumps: Care and Operating Instructions
Comprehensive guide to the care, operation, installation, and safety instructions for Danner Pondmaster Magnetic Drive 2-7 Pumps (models 02512, 02513, 02515, 02517, 02522, 02523, 02525, 02527). Includes troubleshooting, maintenance, and warranty information.
Preview Danner Submersible and In-Line Pumps: Care, Operation, and Conversion Guide
Comprehensive guide to Danner submersible and in-line pumps, covering operating instructions, conversion to in-line use, maintenance, troubleshooting, and warranty information. Includes safety warnings and model details.
Preview Danner Pondmaster Pressurized Filter System: Care and Operating Instructions
User manual for Danner Pondmaster pressurized pond filter systems. Covers installation, operation, maintenance, UV clarifier use, and parts for models CPF and PF series. Essential guide for pond owners.
Preview Danner Manufacturing 2019-2020 Product Catalog for Aquatics and Water Features
Explore the Danner Manufacturing 2019-2020 product catalog, showcasing innovative solutions for aquariums, water gardens, ponds, pools, and home decor. Discover high-quality pumps, filters, clarifiers, and meditation fountains from trusted brands like Pondmaster, Supreme, and ProLine, designed for hobbyists and professionals.
Preview Pondmaster & Supreme Air Pump Diaphragm Kit Installation Instructions
Detailed installation instructions and reference guide for replacing diaphragm kits on Pondmaster and Supreme AP series air pumps. Includes part identification and safety precautions.