Legrand LEG95861

Legrand LEG95861 Timer Instruction Manual

Model: LEG95861

1. Introduction

Thank you for choosing the Legrand LEG95861 Timer. This mechanical plug-in timer is designed to automate the switching of electrical appliances, helping you manage energy consumption and enhance convenience. Please read this manual thoroughly before use to ensure proper installation and operation.

2. Safety Instructions

Always observe the following safety precautions:

  • Do not exceed the maximum load capacity of 3600W (230V).
  • Ensure the timer is securely plugged into a grounded outlet.
  • Do not immerse the timer in water or expose it to excessive moisture.
  • Do not open or attempt to repair the timer yourself. Refer all servicing to qualified personnel.
  • Keep out of reach of children.
  • Unplug the timer from the wall outlet before cleaning.

3. Product Overview

The Legrand LEG95861 Timer is a compact, mechanical plug-in device. It features a large number plate for setting programs and a 2-level switch for operation mode selection.

Legrand LEG95861 Timer, front view showing the dial and switch

Figure 1: Front view of the Legrand LEG95861 Timer. This image displays the main dial for setting time, the segments for programming, and the ON/TIMER switch.

Key Components:

  • Time Dial: The central rotating dial marked with hours (0-24) for current time setting.
  • Program Segments/Sliders: Small, fixed segments around the time dial that can be pushed in or pulled out to set ON/OFF periods.
  • ON/TIMER Switch: A toggle switch to select between continuous ON operation or programmed timer operation.
  • Power Outlet: The socket on the front of the timer where the appliance is plugged in.
  • Power Plug: The prongs on the back of the timer for plugging into a wall outlet.

4. Setup

  1. Unpack: Carefully remove the timer from its packaging.
  2. Plug In: Insert the timer into a standard 230V AC wall outlet.
  3. Set Current Time: Rotate the time dial clockwise until the current time aligns with the arrow or marker on the timer's face. The dial rotates continuously, so ensure you set the correct AM/PM equivalent if your dial uses a 24-hour format.
  4. Connect Appliance: Plug the appliance you wish to control into the power outlet on the front of the timer. Ensure the appliance's power switch is in the "ON" position if it has one.

5. Operating Instructions

Setting the Timer Program:

The timer uses fixed segments around the dial to set ON/OFF periods. Each segment typically represents a specific time interval (e.g., 15 or 30 minutes).

  1. Identify Segments: Locate the small, pushable segments around the outer edge of the time dial.
  2. Set ON Periods: Push the segments inward for the time periods you want the appliance to be ON.
  3. Set OFF Periods: Leave the segments outward for the time periods you want the appliance to be OFF.
  4. Example: If each segment is 15 minutes, and you want an appliance to turn on from 6:00 PM to 8:00 PM, push in all segments corresponding to that 2-hour period.

Selecting Operation Mode:

Use the 2-level ON/TIMER switch to select the desired operation mode:

  • ON Position: The appliance will remain continuously ON, overriding any set timer programs.
  • TIMER Position: The appliance will operate according to the ON/OFF program you have set using the segments.

The timer mechanism will continuously rotate, advancing the time dial and activating/deactivating the appliance based on the pushed-in segments when the switch is in the TIMER position.

6. Maintenance

The Legrand LEG95861 Timer requires minimal maintenance.

  • Cleaning: Disconnect the timer from the power outlet before cleaning. Wipe the exterior with a soft, dry cloth. Do not use liquid cleaners or abrasive materials.
  • Storage: Store the timer in a cool, dry place when not in use.

7. Troubleshooting

Problem Possible Cause Solution
Appliance does not turn ON/OFF at programmed times.
  • 1. ON/TIMER switch is in the "ON" position.
  • 2. Program segments are not set correctly.
  • 3. Current time is not set correctly.
  • 4. Appliance power switch is OFF.
  • 1. Move the switch to the "TIMER" position.
  • 2. Ensure segments are pushed in for ON times and pulled out for OFF times.
  • 3. Rotate the dial to align the current time with the marker.
  • 4. Turn the appliance's power switch to the "ON" position.
Timer dial is not rotating.
  • 1. Timer is not plugged into a live outlet.
  • 2. Internal mechanism fault.
  • 1. Check the wall outlet with another appliance.
  • 2. Contact customer support. Do not attempt to repair.
Appliance remains continuously ON or OFF.
  • 1. ON/TIMER switch is in the wrong position.
  • 2. All segments are pushed in (always ON) or pulled out (always OFF).
  • 1. Ensure the switch is in the "TIMER" position for programmed operation.
  • 2. Adjust the program segments to create desired ON/OFF cycles.

8. Specifications

  • Model: LEG95861
  • Brand: Legrand
  • Operation Mode: ON-OFF
  • Operating Voltage: 230 Volts (AC)
  • Maximum Wattage: 3600 Watts
  • Connector Type: Plug In
  • Switch Type: Toggle (2-level: ON/TIMER)
  • Material: Plastic (body), Brass (contact)
  • Item Dimensions (L x W x H): 35 x 70 x 120 mm
  • International Protection Rating: IP44
  • Control Method: Push Button (for segments) / Timer

9. Warranty and Support

For warranty information or technical support, please refer to the documentation provided with your purchase or visit the official Legrand website. Do not attempt to open or modify the device, as this may void the warranty.

© 2026 Legrand. All rights reserved.