Elinchrom EL23002

Elinchrom Modeling Lamp 100w/230v (EL23002) User Manual

Model: EL23002

1. Introduction

This manual provides essential information for the safe and effective use of your Elinchrom Modeling Lamp 100W (230V). Please read this manual thoroughly before installation and operation to ensure optimal performance and longevity of the product.

2. Product Overview

The Elinchrom Modeling Lamp 100W (230V) is a high-quality E27 base bulb designed for professional photography lighting systems. It offers an average operational life of 500 hours and produces light with a color temperature of approximately 3200K, providing a warm white illumination. This lamp is specifically engineered for compatibility with various Elinchrom heads, including but not limited to EL 250, 250 S, 500, 500 S, 22, 23, 66, S, T, Box Lite, Style 300 / 600, Style FX 100 / 400, and MiniLite, as well as any other fixture that matches the specified voltage and features an E27 base.

Elinchrom Modeling Lamp 100W/230V

Figure 2.1: Elinchrom Modeling Lamp 100W/230V. This image shows the full view of the modeling lamp, highlighting its E27 screw base and the frosted bulb. The Elinchrom branding and specifications (100W 196V, Made in Italy) are visible on the bulb's surface.

3. Features

  • Strong and Portable: Designed for durability and ease of handling.
  • Long Service Life: Engineered to provide years of reliable service.
  • Optimal Compatibility: Specifically designed for Elinchrom studio lighting systems.
  • Standard Base: Features an E27 screw base for wide compatibility with appropriate fixtures.
  • Warm Color Temperature: Produces light at approximately 3200K, ideal for consistent lighting setups.

4. Setup

  1. Power Off: Ensure the lighting unit is completely powered off and unplugged from the mains electricity before handling the lamp.
  2. Cool Down: Allow the existing lamp (if any) and the lighting unit to cool down completely before attempting removal or installation. Hot lamps can cause severe burns.
  3. Handle with Care: Hold the new modeling lamp by its base or the frosted glass, avoiding direct contact with the clear glass surface to prevent oil residue from skin, which can shorten lamp life.
  4. Installation: Carefully screw the E27 base of the modeling lamp into the lamp socket of your Elinchrom lighting unit. Ensure it is securely tightened but do not overtighten.
  5. Power On: Once the lamp is securely installed, plug the lighting unit back into the mains and power it on.

Important Safety Note: Always ensure the correct voltage lamp is used for your specific lighting unit. This lamp is rated for 230V. Using an incorrect voltage lamp can damage the unit or the lamp itself.

5. Operating

The Elinchrom Modeling Lamp functions as a continuous light source within your studio strobe or lighting unit, aiding in previewing light patterns and focus before flash discharge. Its operation is typically controlled by the lighting unit itself.

  • Power Control: The modeling lamp's on/off function and intensity (if supported by your lighting unit) are controlled via the settings on your Elinchrom strobe or power pack. Refer to your specific Elinchrom unit's manual for detailed instructions on modeling lamp control.
  • Purpose: Use the modeling lamp to visualize shadows, highlights, and light spread on your subject before taking a photograph. This helps in precise light placement and composition.
  • Heat Generation: The lamp generates heat during operation. Ensure adequate ventilation around your lighting unit and avoid placing flammable materials near the lamp.

6. Maintenance

Proper maintenance ensures the longevity and optimal performance of your modeling lamp.

  • Cleaning: If the lamp surface becomes dusty, gently wipe it with a soft, dry, lint-free cloth when the lamp is cool and powered off. Do not use abrasive cleaners or liquids.
  • Replacement: Replace the modeling lamp when it burns out or its light output significantly diminishes. Always use genuine Elinchrom replacement lamps to ensure compatibility and performance.
  • Storage: When not in use for extended periods, store the lamp in its original packaging or a protective container in a cool, dry place.

7. Troubleshooting

ProblemPossible CauseSolution
Lamp does not light up.
  • Lamp is burnt out.
  • Lamp not properly seated in socket.
  • No power to the lighting unit.
  • Incorrect voltage lamp.
  • Replace the lamp.
  • Ensure lamp is screwed in securely.
  • Check power cable and wall outlet.
  • Verify lamp voltage (230V) matches unit requirements.
Lamp flickers or is dim.
  • Loose connection.
  • Lamp nearing end of life.
  • Voltage fluctuation.
  • Check lamp seating and unit power connection.
  • Replace the lamp.
  • Ensure stable power supply.
Lamp burns out quickly.
  • Frequent handling or vibration.
  • Overvoltage.
  • Excessive heat buildup.
  • Handle with care; ensure stable setup.
  • Verify power supply voltage.
  • Ensure proper ventilation around the unit.

8. Specifications

BrandElinchrom
Model NumberEL23002
Light TypeHalogen
Wattage100 watts
Voltage230 Volts
Bulb BaseE27
Color TemperatureApproximately 3200 Kelvin
Average Life500 Hours
Product Dimensions4.2 x 2.5 x 2.4 inches
Item Weight1.41 ounces (0.04 Kilograms)
Specific UsesPhotography

Note: Specifications are subject to change without notice. Please refer to the product packaging or official Elinchrom website for the most current information.

9. Warranty Information

Specific warranty details for the Elinchrom Modeling Lamp 100W/230V (EL23002) are not provided in the available product data. For comprehensive warranty information, please refer to the official Elinchrom website or contact Elinchrom customer support directly. Keep your proof of purchase for any warranty claims.

10. Support

For technical assistance, product inquiries, or support, please visit the official Elinchrom website or contact their customer service department. You can often find FAQs, troubleshooting guides, and contact information on their website.

Elinchrom Official Website: www.elinchrom.com

For Amazon-related inquiries, you may visit the Elinchrom Store on Amazon.

Related Documents - EL23002

Preview Elinchrom ONE Quick Start Guide: Setup and Operation
Learn how to set up and use your Elinchrom ONE portable flash with this quick start guide. It covers screen navigation, connection, charging, and essential settings for optimal performance.
Preview Elinchrom ONE Quick Start Guide: Features, Setup, and Operation
A concise guide to setting up and using the Elinchrom ONE portable flash unit, covering screen views, connection, settings, and control panel operation.
Preview Elinchrom Transmitter Pro X Quick Start Guide
A concise guide to setting up and using the Elinchrom Transmitter Pro X, covering connection, interface controls, setup menu options, and regulatory information.
Preview Elinchrom FIVE Battery User Manual - Features, Specs, and Safety
Comprehensive user manual for the Elinchrom FIVE Battery, covering features, technical specifications, charging instructions, safety precautions, and legal information. Learn how to use and maintain your Elinchrom FIVE Battery.
Preview Elinchrom ELC Pro HD Monolight Quick Start Guide and App Features
Comprehensive guide for the Elinchrom ELC Pro HD Monolight, detailing its display panel functions, menu navigation, modeling lamp settings, error codes and solutions, and the Elinchrom Studio App. Includes setup and operational information.
Preview Elinchrom EL-Skyport USB RX: Wireless Flash Trigger and Receiver User Manual
Comprehensive user manual for the Elinchrom EL-Skyport USB RX, detailing its features, installation, operation, troubleshooting, and specifications for wireless flash triggering and remote control.