1. Introduction
This manual provides essential information for the safe and effective use of your Yuasa NP2.3-12FR 12V 2.3AH Sealed Lead-Acid (SLA) battery. Please read these instructions carefully before installation and operation to ensure optimal performance and longevity of the battery.
1.1 Product Overview
The Yuasa NP2.3-12FR is a compact, maintenance-free, sealed lead-acid battery designed for various applications requiring reliable 12-volt power. Its flame-retardant casing enhances safety in critical environments.

Image 1.1: Yuasa NP2.3-12FR 12V 2.3AH Battery. This image shows the compact, rectangular battery with its terminals visible on top.
1.2 Safety Information
WARNING: Lead-acid batteries contain sulfuric acid and lead, which are hazardous materials. Improper handling can cause severe injury or damage. Always wear appropriate personal protective equipment (PPE) including eye protection and gloves when handling batteries.
Proposition 65 Warning: This product can expose you to chemicals including lead and lead compounds, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
- Do not short-circuit the battery terminals.
- Do not expose the battery to open flames or excessive heat.
- Do not disassemble, puncture, or modify the battery.
- Keep out of reach of children.
- Recycle batteries responsibly. Do not dispose of in household waste.
2. Setup and Installation
Follow these steps for proper installation of your Yuasa NP2.3-12FR battery.
2.1 Pre-Installation Check
- Inspect the battery for any physical damage (cracks, leaks, swollen casing). Do not use a damaged battery.
- Ensure the battery voltage (12V) and capacity (2.3AH) match the requirements of your application.
- Verify that the F2 terminals are compatible with your existing connectors.
2.2 Installation Steps
- Safety First: Disconnect power to the device or system before installing the battery. Wear protective eyewear and gloves.
- Positioning: Place the battery in a well-ventilated area, away from direct sunlight, heat sources, and flammable materials. Ensure it is secured to prevent movement or vibration.
- Connecting Terminals:
- Connect the positive (+) terminal of the battery to the positive lead of your device.
- Connect the negative (-) terminal of the battery to the negative lead of your device.
- Final Check: Double-check all connections for correct polarity and tightness.
3. Operating Instructions
The Yuasa NP2.3-12FR is a sealed, maintenance-free battery. It does not require water additions or electrolyte checks.
- The battery is designed for float or cyclic applications.
- Avoid deep discharges as they can shorten battery life.
- Operate the battery within its specified temperature range (typically 20°C to 25°C for optimal life).
4. Maintenance
Proper maintenance ensures the longevity and reliability of your battery.
4.1 Charging
- Use a charger specifically designed for 12V sealed lead-acid batteries.
- Do not overcharge or undercharge the battery, as both can reduce its lifespan.
- Recommended float charge voltage: 13.5 to 13.8 volts at 20°C (68°F).
- Recommended cyclic charge voltage: 14.4 to 15.0 volts at 20°C (68°F).
- The maximum initial charging current should not exceed 0.69A (0.3CA).
4.2 Storage
- Store the battery in a cool, dry, and well-ventilated area.
- Ensure the battery is fully charged before storage.
- For extended storage, recharge the battery every 3-6 months to prevent sulfation and capacity loss.
4.3 Cleaning
- Keep the battery terminals and casing clean and free of dirt or corrosion.
- Use a damp cloth to wipe the exterior. Do not use solvents or harsh chemicals.
- If corrosion is present on terminals, clean with a wire brush and a solution of baking soda and water, then rinse with clean water and dry thoroughly.
5. Troubleshooting
This section addresses common issues you might encounter with your battery.
| Problem | Possible Cause | Solution |
|---|---|---|
| Battery not holding charge | Undercharging, overcharging, sulfation, end of life. |
|
| Device not powering on | Low battery charge, loose connections, incorrect polarity. |
|
| Battery casing is swollen or leaking | Overcharging, internal damage, excessive heat. | Immediately discontinue use. This indicates a severe fault. Safely disconnect and replace the battery. Do not attempt to charge or use a swollen/leaking battery. |
If you experience issues not covered here, or if troubleshooting steps do not resolve the problem, contact customer support.
6. Specifications
| Feature | Detail |
|---|---|
| Model Number | NP2.3-12FR |
| Voltage | 12 Volts (DC) |
| Capacity | 2.3 AH |
| Battery Cell Composition | Sealed Lead Acid (SLA) |
| Number of Cells | 6 |
| Terminal Type | F2 Terminal |
| Dimensions (L x W x H) | 7.24 x 3.11 x 1.73 inches (approx. 18.4 x 7.9 x 4.4 cm) |
| Item Weight | 1.96 pounds (approx. 0.89 kg) |
| Manufacturer | YUASA |
7. Warranty and Support
For warranty information, please refer to the documentation provided at the time of purchase or contact your retailer. Yuasa batteries are manufactured to high-quality standards.
For technical support or inquiries, please visit the official Yuasa website or contact their customer service department. Keep your purchase receipt and battery model number handy for faster service.
Online Resources: www.yuasabatteries.com