1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of the Caleffi 302 631 Boiler Group. Please read these instructions carefully before installation and use to ensure safe and efficient operation. Retain this manual for future reference.

Important Safety Information: Always ensure that installation and maintenance are performed by qualified personnel in accordance with local regulations and standards. Disconnect power and depressurize the system before any service.

2. Product Overview and Components

The Caleffi 302 631 Boiler Group is a pre-assembled safety unit designed for home heating systems with a power output up to 50 kW. It is constructed from durable brass and includes key safety and operational components.

Caleffi 302 631 Boiler Group with pressure gauge, safety valve, and automatic air vent.

Figure 1: Caleffi 302 631 Boiler Group. This image displays the Caleffi 302 631 Boiler Group, a pre-assembled unit designed for home heaters. It features a brass body, a visible pressure gauge for monitoring system pressure, a safety valve with a red cap for pressure relief, and an automatic quick bleed vent at the top for air removal. The unit is shown resting on a grey insulating material.

Key components include:

  • Pressure Gauge: Indicates the current pressure within the boiler system.
  • Safety Valve: Automatically releases excess pressure to prevent system damage. Features a red cap.
  • Quick Bleed Vent: Automatically expels air from the system, improving efficiency and preventing airlocks.

3. Setup and Installation

The Caleffi 302 631 Boiler Group is designed for straightforward installation. It is suitable for heating systems up to 50 kW, adhering to DIN 4751 standards.

3.1 Pre-Installation Checks

  • Verify that the boiler group is compatible with your heating system's specifications.
  • Inspect the unit for any visible damage from shipping.
  • Ensure all necessary tools and additional plumbing components are available.

3.2 Installation Steps

  1. Turn off the boiler and allow it to cool. Isolate the system and drain it if necessary.
  2. Identify the appropriate connection points on your boiler for the safety group.
  3. Connect the Caleffi 302 631 Boiler Group to the system using appropriate fittings. Ensure all connections are tight and leak-free.
  4. Position the quick bleed vent at the highest point possible to facilitate air removal.
  5. Ensure the discharge pipe from the safety valve is correctly routed to a safe drainage point, preventing scalding or property damage.
  6. Refill the system and carefully check for leaks.
  7. Bleed any remaining air from the system using the quick bleed vent or other system bleed points.

4. Operating Instructions

Once installed, the Caleffi 302 631 Boiler Group operates largely automatically to maintain system safety and efficiency.

4.1 Monitoring System Pressure

  • Regularly observe the pressure gauge. The optimal operating pressure range is typically indicated by a green zone on the gauge face.
  • If the pressure consistently falls below the recommended range, the system may need to be refilled.
  • If the pressure consistently exceeds the recommended range, the safety valve should activate. If it does not, or if pressure continues to rise, immediately shut down the boiler and consult a qualified technician.

4.2 Automatic Air Vent Function

The quick bleed vent automatically releases air that accumulates in the system. No manual intervention is typically required during normal operation. Ensure the vent cap is not overtightened, allowing air to escape.

5. Maintenance

Regular maintenance ensures the longevity and reliable operation of your Caleffi Boiler Group.

5.1 Safety Valve Check

  • It is recommended to manually test the safety valve at least once a year.
  • To test, briefly turn the red cap or lever to allow a small amount of water to discharge. This helps prevent the valve from seizing.
  • Ensure the discharge pipe is clear and safely routed before performing this test.
  • If the valve does not operate freely or leaks after testing, it must be replaced.

5.2 Quick Bleed Vent Inspection

  • Periodically check the quick bleed vent for any signs of leakage or blockage.
  • Ensure the vent cap is slightly loosened (as per manufacturer's instructions for automatic vents) to allow air release.

5.3 General Cleaning

Keep the exterior of the boiler group clean. Avoid using abrasive cleaners that could damage the brass or plastic components.

6. Troubleshooting

This section addresses common issues you might encounter with the Caleffi 302 631 Boiler Group.

ProblemPossible CauseSolution
Pressure gauge reading is too low.Insufficient water in the system.Refill the heating system to the recommended pressure. Check for leaks.
Pressure gauge reading is too high.System overfilled, expansion vessel fault, or safety valve malfunction.Check expansion vessel. If pressure continues to rise and safety valve does not activate, shut down boiler and contact a technician.
Water dripping from safety valve.Normal operation (minor discharge due to pressure fluctuations), or valve seat contamination/failure.If minor, it may be normal. If continuous or excessive, test valve. If issue persists, valve may need cleaning or replacement.
Water dripping from quick bleed vent.Normal operation (expelling air/water), or vent malfunction.Ensure vent cap is not overtightened. If continuous leakage, the vent may need replacement.
No air being released from vent.Vent cap overtightened or vent blocked.Loosen vent cap slightly. Clean vent if necessary. Replace if still not functioning.

For issues not listed here or if solutions do not resolve the problem, contact a qualified heating technician.

7. Specifications

Detailed technical specifications for the Caleffi 302 631 Boiler Group:

SpecificationDetail
Model Number302 631
ManufacturerCaleffi S.p.A.
Part Number9001802
Maximum Boiler PowerUp to 50 kW
MaterialBrass, Plastic
Item Weight2.2 pounds (approx. 1 kg)
Product Dimensions (L x W x H)9.84 x 3.15 x 7.87 inches (approx. 25 x 8 x 20 cm)
Included ComponentsBoiler group (pre-assembled with pressure gauge, safety valve, quick bleed vent)
CertificationKesselsicherheitsgruppe (Boiler Safety Group)

8. Warranty Information

For detailed warranty terms and conditions, please refer to the official warranty documentation provided with your purchase or visit the Caleffi S.p.A. official website. Warranty coverage typically applies to manufacturing defects and is subject to proper installation and use as outlined in this manual.

9. Support

If you require technical assistance, have questions regarding installation, operation, or maintenance, or need to report a product issue, please contact Caleffi S.p.A. customer support or your authorized Caleffi dealer.

Manufacturer: Caleffi S.p.A.

For contact information, please visit the official Caleffi website: www.caleffi.com

Related Documents - 302 631

Preview Caleffi Z-one Relay ZVR Series: Multi-Zone Valve Switching Control
Technical specifications, features, and connection details for the Caleffi Z-one Relay ZVR series multi-zone valve switching control system, designed for hydronic heating applications.
Preview Caleffi DYNAMICAL® Dynamic Thermostatic Radiator Valves 230-237 Series - Technical Specification
Detailed technical specifications, operating principles, and application guide for Caleffi DYNAMICAL® series 230-237 dynamic thermostatic radiator valves, offering automatic balancing and pressure independence for efficient heating systems.
Preview Caleffi Série 108 Nezámrzný ventil - Technická specifikace
Podrobné technické specifikace, funkce, instalace a návod k údržbě pro Caleffi Série 108 nezámrzný ventil, navržený k ochraně před poškozením mrazem v HVAC systémech.
Preview Codice Etico di Gruppo Caleffi: Principi e Condotta
Il Codice Etico del Gruppo Caleffi stabilisce i principi e i doveri di condotta per una gestione aziendale corretta, integrando la sostenibilità e guidando le azioni di tutti gli stakeholder.
Preview Caleffi LEGIOMIX® 6000 Series Electronic Mixing Valve Installation and Commissioning Manual
Comprehensive guide for installing and commissioning the Caleffi LEGIOMIX® 6000 series electronic mixing valve. Learn about its function, technical specifications, safety precautions, and operation for precise domestic hot water temperature control and thermal disinfection.
Preview Caleffi 166 Series Thermostatic Regulating Unit for Heating Systems | Technical Specifications & Installation
Detailed information on the Caleffi 166 series thermostatic regulating unit for heating systems, including functions, product range, technical specifications, dimensions, operating principles, installation, and accessories. Features high-efficiency circulators and precise temperature control for radiant floor panels and radiators.