1. Introduction

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Airflow Icon 15S Low Voltage Extractor Fan. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.

The Airflow Icon 15S is a low voltage (12V DC) axial extractor fan designed for effective ventilation in domestic environments, including bathrooms and cloakrooms. It features a 100mm (4 inch) outlet and an iris shutter mechanism that opens when the fan is active and closes when off, preventing back draughts. The fan can be mounted either on a surface or recessed into a wall or ceiling and operates via a 12V DC transformer. Various optional control modules are available to enhance its functionality.

2. Safety Information

WARNING: Electrical installation should only be performed by a qualified electrician in accordance with local wiring regulations.

  • Always disconnect the power supply before installation, maintenance, or servicing.
  • Ensure the fan is correctly earthed if required by local regulations.
  • Do not install the fan where it may be exposed to direct water spray or excessive humidity beyond its IPX4 rating.
  • Keep children and unauthorized persons away from the installation area.
  • Ensure all wiring connections are secure and properly insulated.
  • Do not obstruct the fan's airflow during operation.
  • This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

3. Product Overview

The Airflow Icon 15S features a sleek design with an integrated iris shutter. The fan is designed for discreet integration into various room decors.

Airflow Icon 15S Extractor Fan with Iris Shutter Closed

Figure 3.1: Front view of the Airflow Icon 15S fan with the iris shutter closed, showing the smooth, unobtrusive design and the 'AIRFLOW iCON' logo.

Airflow Icon 15S Extractor Fan with Iris Shutter Open

Figure 3.2: Front view of the Airflow Icon 15S fan with the iris shutter open, revealing the internal fan blades and grille for ventilation.

Airflow Icon 15S Extractor Fan Side Profile

Figure 3.3: Side profile view of the Airflow Icon 15S fan, illustrating its compact depth and the duct connection point.

4. Specifications

Detailed technical specifications for the Airflow Icon 15S fan are provided below. For a visual representation of dimensions and other data, refer to Figure 4.1.

FeatureSpecification
BrandAirflow
Model NameiCON 15S
Electric Fan DesignExhaust Fan
Power SourceCorded Electric (12V DC Transformer)
Room TypeBathroom, Cloakroom
Special FeaturesRemote Controlled (with optional module), Water Resistant (IPX4), Timer (with optional module), Silent Operation
Recommended UsesVentilating
Noise Level32.4 Decibels
Wattage6.1 watts (Fan only), 7.5 watts (Total consumption)
Air Flow Capacity79 Cubic Meters Per Hour (21.9 Liters Per Second)
Voltage12 Volts (DC)
Item Weight1.13 Kilograms (2.48 pounds)
Included ComponentsCord (for transformer connection)
Indoor/Outdoor UsageIndoor
Specification MetCE
Installation TypeWall Mount, Ceiling Mount (Surface or Recessed)
Product Dimensions4.27 x 7.76 x 7.76 inches (108.5 x 197 x 197 mm)
Ingress Protection RatingIPX4
Max Ambient Temperature40 °C
Airflow Icon 15S Technical Data, Dimensions, Covers, and Performance Graph

Figure 4.1: Consolidated technical data for the Airflow Icon 15S, including specifications, available cover colors, detailed dimensions (in mm), and a static pressure vs. airflow performance graph.

5. Installation

Installation should be carried out by a qualified professional. Ensure the power supply is disconnected before commencing work.

Airflow Icon 15S Wall and Ceiling Installation Diagrams

Figure 5.1: Diagrams illustrating various installation methods for the Airflow Icon 15S, including recessed and surface mounting on walls and ceilings, along with best practice recommendations for flexible ducting.

5.1 Wall Installation

Recessed Wall Mounting

  • The iCON 15S requires a 110mm diameter hole through the wall.
  • The hole should be lined with a 100mm internal diameter duct.
  • Secure the fan within the prepared opening using appropriate fixings.

Surface Wall Mounting

  • When surface mounting, use the supplied mounting skirt.
  • The iCON 15S requires a 100mm internal diameter duct for connection.
  • Ensure all vapor barriers are properly restored after installation.

5.2 Ceiling Installation

Recessed Ceiling Mounting

  • The iCON 15S requires a 110mm diameter hole through the ceiling.
  • The fan should be fitted into the hole and fixed with screws provided into the support structure.

Surface Ceiling Mounting

  • When surface mounting, use the supplied mounting skirt.
  • The fan is then fitted into the skirt and secured.
  • For recessed or surface mounting in a ceiling, a plywood support (min. 18mm thick) must be mounted between the ceiling joists. Any fixing screws should be fitted through the plasterboard into the support.

5.3 Ducting Recommendations

  • Where flexible ducting is used, the diameter must be maintained.
  • It is good ventilation practice that the ducting is extended to a minimum of 90% its possible length in order to maintain the best possible airflow.
  • Ensure that flexible duct connections are not overtightened to the spigots.
  • To maximize airflow, rigid ducting should be used where possible.
  • Fan and ducting installation must comply with the requirements of the Domestic Ventilation Compliance Guide and relevant Building Regulations.

6. Operating Instructions

The basic Airflow Icon 15S fan operates when power is supplied to its 12V DC transformer, typically controlled by a remote switch (e.g., a light switch). For advanced functionalities, optional plug-in modules are required.

6.1 Basic Operation

  • When the fan receives power, the iris shutter will open, and the fan will begin to extract air.
  • When power is removed, the fan will stop, and the iris shutter will close, preventing back draughts.

6.2 Operation with Optional Modules

Refer to Section 8, "Optional Modules," for details on specific module functionalities such as pull cord, timer, humidity sensor, and PIR motion detection.

7. Maintenance

Regular cleaning and maintenance will ensure the longevity and efficient operation of your Airflow Icon 15S fan. Always disconnect the power supply before performing any maintenance.

  • Cleaning the Exterior: Wipe the exterior casing with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Cleaning the Iris Shutter and Blades: Carefully open the iris shutter (if possible, or remove the cover as per installation instructions) and gently clean any dust or debris from the shutter mechanism and fan blades using a soft brush or cloth. Ensure no foreign objects obstruct the shutter's movement.
  • Inspection: Periodically check for any signs of damage to the casing, wiring, or fan components. If any damage is found, consult a qualified technician.
  • Do not lubricate any part of the fan.

8. Optional Modules

The Airflow Icon 15S fan can be enhanced with various plug-in modules to provide additional control features. These modules are sold separately and are quick and easy to install.

Airflow Icon 15S Optional Modules and Cover Colors

Figure 8.1: Table detailing available optional modules for the iCON SELV 12V series, including their part numbers and descriptions, as well as optional cover colors for iCON 15S and iCON 30S models.

Available iCON SELV 12V Optional Modules:

Part No.ModelDescription
72573603PCSPull cord (Manual on/off)
72574204PCTSPull cord timer (Run on timer 1-30 min)
72682307DTSDelayed timer (2 min delay, Run on timer 2-45 min, Pull cord)
72574202HTSHumidity timer (40-90% RH, Run on timer 2-45 min, Pull cord)
72574203PRTSPIR timer (Motion sensor, Run on timer 2-45 min)
72574201PRHTSPIR with humidity timer (Motion sensor, 40-90% RH, Run on timer)

9. Troubleshooting

If you encounter issues with your Airflow Icon 15S fan, refer to the table below for common problems and their potential solutions. Always disconnect power before inspecting the unit.

ProblemPossible CauseSolution
Fan does not operateNo power supply; Faulty wiring; Faulty transformer; Faulty module (if installed).Check power supply at the switch; Verify wiring connections; Test transformer output; Replace module if necessary. Consult a qualified electrician.
Iris shutter does not open/close properlyObstruction by dust/debris; Mechanical fault in shutter mechanism.Disconnect power and carefully clean the shutter and surrounding area; If problem persists, contact support.
Reduced airflow/poor extractionObstructed ducting; Dirty fan blades; Incorrect ducting installation.Check ducting for blockages or kinks; Clean fan blades; Ensure ducting meets installation guidelines (e.g., correct diameter, minimal bends).
Excessive noise during operationLoose mounting; Obstruction in fan blades; Motor issue.Ensure fan is securely mounted; Disconnect power and check for debris in blades; If motor noise, contact support.

10. Warranty Information

The Airflow Icon 15S Low Voltage Extractor Fan is typically supplied with a 3-year warranty from the date of purchase, covering manufacturing defects. This warranty does not cover damage resulting from improper installation, misuse, neglect, unauthorized repairs, or normal wear and tear.

Please retain your proof of purchase for warranty claims. For specific warranty terms and conditions, refer to the documentation provided at the time of purchase or contact Airflow customer support.

11. Customer Support

For technical assistance, spare parts, or warranty inquiries, please contact Airflow customer support. Ensure you have your product model (iCON 15S) and proof of purchase available when contacting support.

Airflow Contact Information:
Please refer to the official Airflow website or your product packaging for the most current contact details.

Related Documents - iCON 15S

Preview Airflow iCON SELV 12V Fan Range: Installation and Operating Guide
Comprehensive installation and operating guide for the Airflow iCON SELV 12V DC fan range, covering dimensions, electrical and mechanical installation, maintenance, and warranty. Features Safety Extra Low Voltage (SELV) fans suitable for domestic premises.
Preview Airflow iCON 230V Fan Range: Installation and Operating Guide
Comprehensive installation and operating guide for the Airflow iCON 230V fan range, detailing electrical and mechanical installation, optional modules, maintenance, and warranty information.
Preview Airflow iCON 15/30 Spares Kit with Actuator - Instruction Manual
Detailed instruction manual for installing the Airflow iCON 15/30 spares kit, including the actuator, clip, spring, and screws. Learn how to replace parts for your iCON fan.
Preview Airflow iCON 30S Ventilation Fan: Stylish, Efficient Bathroom Ventilation
Discover the Airflow iCON 30S, a stylish and efficient 12V DC ventilation fan for en-suites, bathrooms, and utility rooms. Featuring a Reddot Design Award winning silent iris shutter, low energy consumption, and multiple control module options.
Preview Airflow Aura-eco 100mm & 150mm Axial Fans: Installation and Operating Instructions
This document provides comprehensive installation, operating, and maintenance instructions for the Airflow Aura-eco 100mm and 150mm axial fans. It includes safety guidelines, technical specifications, connection diagrams, sensor adjustments, and warranty information.
Preview Airflow Aura In-line Fan With Kit Installation and Operating Guide
Comprehensive installation, operation, and maintenance guide for the Airflow Aura In-line Fan With Kit, including technical specifications, wiring diagrams, and warranty information.