Panduit NKFP24Y

Panduit NKFP24Y Category-6 24-Port Flat Modular Patch Panel

Instruction Manual

Model: NKFP24Y | Brand: Panduit

1. Introduction

The Panduit NKFP24Y is a 24-port, 1 RU (Rack Unit) flat modular patch panel designed for efficient cable management and network connectivity. It provides front access to installed modules, simplifying moves, adds, and changes within your network infrastructure. This patch panel supports various module types, including UTP, fiber optic, and audio/video, allowing for flexible system configurations.

Key Features:

  • 24-port capacity in a 1 RU design.
  • Front access for easy module installation, removal, and maintenance.
  • Accepts Keystone Modules for UTP, STP, fiber optic, and audio/video applications.
  • Designed for mounting to standard TIA/EIA 19-inch racks.
  • Features for clear port and panel identification.
Panduit NKFP24Y 24-Port Flat Modular Patch Panel

Figure 1: Front view of the Panduit NKFP24Y 24-Port Flat Modular Patch Panel.

2. Safety Information

Please read and understand all safety instructions before installing or operating this product. Failure to follow these instructions may result in injury or damage to the equipment.

  • Always disconnect power to any active equipment before working on network connections.
  • Ensure proper grounding for all connected devices.
  • Use appropriate tools for installation to prevent damage to the panel or modules.
  • Do not expose the patch panel to moisture or extreme temperatures.
  • Handle fiber optic cables and modules with care to avoid damage to delicate components.

3. Package Contents

Verify that all items are present in the package. If any items are missing or damaged, contact your supplier immediately.

  • Panduit NKFP24Y 24-Port Flat Modular Patch Panel
  • Installation Tool (for module termination, if included with specific modules)
  • Mounting Screws (typically supplied with rack or purchased separately)

4. Setup and Installation

4.1 Rack Mounting

  1. Identify an available 1 RU space in your standard TIA/EIA 19-inch equipment rack. For 23-inch racks, an optional extender bracket (sold separately) is required.
  2. Align the mounting holes on the patch panel with the corresponding holes on the rack rails.
  3. Secure the patch panel to the rack using appropriate rack screws (not included). Ensure the panel is level and firmly attached.

4.2 Module Installation

The NKFP24Y patch panel is designed to accept Keystone style modules. For Mini-Com modules, please verify compatibility with Panduit documentation or support, as not all Mini-Com modules are compatible with Keystone-style panels.

  1. Ensure the patch panel is securely mounted.
  2. Take a compatible Keystone module (e.g., Category-6 UTP, fiber optic, or audio/video).
  3. Align the module with an empty port on the front of the patch panel. The module should snap into place with a gentle push. Ensure it is fully seated and secure.
  4. Repeat for all desired ports.
  5. For module removal, gently press the release tab (if present on the module) or use a small flat-head tool to carefully pry the module out from the front.
Illustration of a modular jack

Figure 2: Example of a modular jack, which snaps into the patch panel.

5. Operating Instructions

Once the patch panel is installed and modules are in place, it functions as a central connection point for your network cabling.

  1. Cable Termination: Terminate your network cables (e.g., Category-6 UTP) to the rear of the installed modules according to the module's specific wiring diagram (T568A or T568B). Use a punch-down tool if applicable.
  2. Front Connections: Connect patch cords from your network devices (switches, servers, workstations) to the front ports of the patch panel.
  3. Identification: Utilize the port and panel identification features to label each connection clearly. This aids in troubleshooting and future network management.
  4. Moves, Adds, Changes (MACs): The front-removable faceplates and snap-in modules allow for easy reconfiguration. To change a connection, simply disconnect the patch cord, remove the module if necessary, and reconfigure as required.

6. Maintenance

Regular maintenance helps ensure optimal performance and longevity of your patch panel.

  • Cleaning: Periodically clean the front and rear of the patch panel with a soft, dry, lint-free cloth. Avoid using harsh chemicals or abrasive materials.
  • Inspection: Visually inspect all connections and modules for any signs of damage, loose connections, or wear.
  • Cable Management: Ensure proper cable management practices are followed to prevent strain on connections and maintain airflow within the rack.

7. Troubleshooting

If you encounter issues with your patch panel, consider the following troubleshooting steps:

  • No Network Connectivity:
    • Verify that all cables are securely connected at both the patch panel and the network device.
    • Check the integrity of the patch cords. Try swapping with a known good cable.
    • Ensure the module is correctly terminated to the rear cable and fully seated in the patch panel.
    • Confirm that the network device (switch, router) port is active and configured correctly.
  • Loose Module:
    • Gently push the module back into the port until it clicks into place.
    • If the module repeatedly comes loose, inspect the module and the patch panel port for damage.
  • Module Compatibility:
    • This patch panel is designed for Keystone modules. If using Panduit Mini-Com modules, ensure they are specifically designed for Keystone compatibility. Refer to Panduit's official documentation for specific module compatibility.

8. Specifications

Attribute Specification
Model Number NKFP24Y
Brand Panduit
Ports 24
Rack Units (RU) 1 RU
Material Cold Rolled Steel
Color Black
Product Dimensions 19"W x 1.72"H
Finish Type Polished
Installation Type Screw-In (Rack Mount)
Item Weight 9.9 ounces (approx. 0.62 Pounds)
Certification EIA, TIA
UPC 074983055937

9. Warranty and Support

9.1 Warranty Information

This Panduit NKFP24Y patch panel is covered by a Panduit limited 6-month manufacturer's warranty. This warranty typically covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full details and terms, refer to the official Panduit warranty statement available on their website or contact Panduit customer service.

9.2 Customer Support

For technical assistance, product inquiries, or warranty support, please contact Panduit customer service. Visit the official Panduit website for contact information, FAQs, and additional resources.

Panduit Official Website: www.panduit.com

Related Documents - NKFP24Y

Preview Panduit Opticom QuickNet Rack Mount Fiber Cassette Enclosures Installation Instructions
This document provides detailed installation instructions for Panduit Opticom QuickNet Rack Mount Fiber Cassette Enclosures, including models FCE1U, FCE1UA, and FCE2U. It covers preparation, rack mounting, grommet cutting, cassette installation, fiber routing, and door re-attachment.
Preview Panduit Opti-Com Fiber Optic Splice Cassettes Installation Guide
Installation instructions for Panduit Opti-Com™ Fiber Optic Splice Cassettes, including part numbers, components, and step-by-step assembly guidance.
Preview Panduit Keystone Stainless Steel Phone Plate Kits Installation and Removal Guide
Step-by-step installation and removal instructions for Panduit Keystone Stainless Steel Phone Plate Kits (KWPK5E, KWPK6) with included jack modules. Includes technical support information.
Preview Panduit ACF06L Smart Rack Handle: User Manual, Features, & Specifications
User manual for the Panduit ACF06L Smart Rack Handle, detailing its features including integrated humidity sensor, keypad, RFID reader, electronic and mechanical lock functions, LED indicators, and compliance information for secure data center rack management.
Preview Panduit Keystone Stainless Steel Phone Plate Kits Installation Instructions
Step-by-step installation and removal instructions for Panduit Keystone Stainless Steel Phone Plate Kits (KWP5EY, KWP6PY), including technical support contact information.
Preview Panduit Mini-Com Corrosive Resistant UTP Jack Module Installation Guide
Comprehensive installation instructions and best practices for Panduit Mini-Com Corrosive Resistant UTP Jack Modules (CJE6X88**). Covers termination steps, T568A/B wiring standards, removal procedures, and proper orientation for optimal performance.