1. Introduction
This instruction manual provides essential information for the safe and proper installation, operation, and maintenance of the Goodman 0151F00000PS Gas Valve. This component is designed as a replacement part for compatible HVAC systems. Please read this manual thoroughly before attempting any installation or service.
2. Safety Information
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer, service agency, or gas supplier.
- Always shut off the main gas supply and electrical power to the appliance before installing or servicing the gas valve.
- Verify that the replacement valve is compatible with your appliance's specifications.
- Check for gas leaks after installation using a non-corrosive leak detection solution. Never use an open flame.
- Ensure proper ventilation during installation and operation.
- Follow all local codes and regulations for gas appliance installation.
3. Product Description and Features
The Goodman 0151F00000PS is an OEM replacement gas valve designed for specific Goodman HVAC systems. It is a critical component for controlling gas flow to the burner assembly.

Figure 1: Front view of the Goodman 0151F00000PS Gas Valve, showing control knobs and electrical connections.
Key Features:
- Genuine Goodman OEM part.
- Designed for reliable gas flow control.
- Country Of Origin: United States.
- Item Package Weight: 5.75 lb.
- Item Package Dimension: 16.0" L x 16.0" W x 13.0" H.

Figure 2: Side view of the Goodman 0151F00000PS Gas Valve, illustrating its approximate dimensions for installation planning.
4. Setup and Installation
Installation of the Goodman 0151F00000PS Gas Valve should only be performed by a qualified HVAC technician or gas professional. Incorrect installation can lead to serious hazards.
General Installation Steps (Consult Appliance Manual for Specifics):
- Preparation: Turn off all electrical power and gas supply to the appliance. Allow the appliance to cool down.
- Access: Gain access to the existing gas valve within the appliance.
- Disconnect: Carefully disconnect the gas lines and electrical wiring from the old valve. Be prepared for residual gas in the lines.
- Remove Old Valve: Unmount and remove the old gas valve.
- Install New Valve: Mount the new Goodman 0151F00000PS Gas Valve in the same orientation as the old one. Ensure all connections are clean and free of debris.
- Connect Gas Lines: Apply appropriate pipe sealant (suitable for gas) to threaded connections and securely attach the gas lines to the inlet and outlet ports. The valve features 4.8-inch flare inlet and outlet connection sizes.
- Connect Wiring: Reconnect the electrical wiring according to the appliance's wiring diagram. Ensure all connections are secure.
- Leak Test: Slowly turn on the main gas supply. Use a non-corrosive leak detection solution to check all gas connections for leaks. Bubbles indicate a leak. If a leak is detected, shut off gas, tighten connections, and re-test.
- Restore Power: Once confident there are no leaks, restore electrical power to the appliance.
- Test Operation: Follow the appliance manufacturer's instructions to test the operation of the gas valve and burner.
5. Operating Instructions
The Goodman 0151F00000PS Gas Valve operates in conjunction with your appliance's control system. Its primary function is to regulate the flow of gas. Operation typically involves the following states:
- OFF: No gas flow to the burner.
- ON: Allows gas flow to the burner when called for by the appliance's thermostat and safety controls.
- Pilot (if applicable): Some systems may have a pilot setting for lighting a standing pilot. Refer to your appliance's specific instructions.
Always refer to your specific appliance's user manual for detailed operating procedures, including startup and shutdown sequences.
6. Maintenance
The Goodman 0151F00000PS Gas Valve is designed for reliable operation and generally requires minimal maintenance. However, periodic inspection by a qualified technician is recommended as part of overall appliance maintenance.
- Annual Inspection: Have a qualified technician inspect the gas valve and all gas connections annually for signs of wear, corrosion, or leaks.
- Cleanliness: Ensure the area around the gas valve is kept clean and free of dust, debris, or obstructions.
- Do Not Lubricate: Do not attempt to lubricate the gas valve. Internal components are factory-lubricated and designed for specific operation.
7. Troubleshooting
If your appliance is not functioning correctly after gas valve installation, consider the following general troubleshooting steps. For complex issues, always consult a qualified HVAC technician.
- No Gas Flow:
- Check if the main gas supply valve is open.
- Verify the gas valve's control knob (if present) is in the "ON" position.
- Ensure electrical power to the appliance is on and the thermostat is calling for heat.
- Check for any tripped circuit breakers or blown fuses.
- Gas Leak Odor:
- If you smell gas, immediately evacuate the premises, do not operate any electrical switches, and contact your gas supplier and emergency services from a safe location.
- Appliance Not Igniting:
- This could be related to the igniter, flame sensor, or other safety controls, not necessarily the gas valve itself. Consult your appliance's manual or a technician.
8. Specifications
Detailed technical specifications for the Goodman 0151F00000PS Gas Valve:
| Brand | Goodman |
| Model Number | 0151F00000PS |
| Item Dimensions (L x W x H) | 13 x 13 x 10 inches |
| Inlet Connection Size | 4.8 Inches |
| Inlet Connection Type | Flare |
| Outlet Connection Type | Flare |
| Number of Ports | 2 |
| Outlet Connection Size | 4.8 Inches |
| Specification Met | ANSI, ASME, ASTM |
| Item Weight | 3 pounds |
| Country of Origin | United States |
9. Warranty and Support
For warranty information regarding the Goodman 0151F00000PS Gas Valve, please refer to the documentation provided with your original appliance or contact Goodman directly. Warranty terms typically cover manufacturing defects and may vary.
For technical support or assistance with installation and troubleshooting, it is highly recommended to contact a qualified HVAC professional or the Goodman customer service department.
Goodman Contact Information: Please visit the official Goodman website for the most current contact details and support resources.