1. Introduction

This instruction manual provides essential information for the safe and proper installation, operation, and maintenance of the Goodman 0151F00000PS Gas Valve. This component is designed as a replacement part for compatible HVAC systems. Please read this manual thoroughly before attempting any installation or service.

2. Safety Information

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Installation and service must be performed by a qualified installer, service agency, or gas supplier.

3. Product Description and Features

The Goodman 0151F00000PS is an OEM replacement gas valve designed for specific Goodman HVAC systems. It is a critical component for controlling gas flow to the burner assembly.

Goodman 0151F00000PS Gas Valve

Figure 1: Front view of the Goodman 0151F00000PS Gas Valve, showing control knobs and electrical connections.

Key Features:

Goodman 0151F00000PS Gas Valve dimensions

Figure 2: Side view of the Goodman 0151F00000PS Gas Valve, illustrating its approximate dimensions for installation planning.

4. Setup and Installation

Installation of the Goodman 0151F00000PS Gas Valve should only be performed by a qualified HVAC technician or gas professional. Incorrect installation can lead to serious hazards.

General Installation Steps (Consult Appliance Manual for Specifics):

  1. Preparation: Turn off all electrical power and gas supply to the appliance. Allow the appliance to cool down.
  2. Access: Gain access to the existing gas valve within the appliance.
  3. Disconnect: Carefully disconnect the gas lines and electrical wiring from the old valve. Be prepared for residual gas in the lines.
  4. Remove Old Valve: Unmount and remove the old gas valve.
  5. Install New Valve: Mount the new Goodman 0151F00000PS Gas Valve in the same orientation as the old one. Ensure all connections are clean and free of debris.
  6. Connect Gas Lines: Apply appropriate pipe sealant (suitable for gas) to threaded connections and securely attach the gas lines to the inlet and outlet ports. The valve features 4.8-inch flare inlet and outlet connection sizes.
  7. Connect Wiring: Reconnect the electrical wiring according to the appliance's wiring diagram. Ensure all connections are secure.
  8. Leak Test: Slowly turn on the main gas supply. Use a non-corrosive leak detection solution to check all gas connections for leaks. Bubbles indicate a leak. If a leak is detected, shut off gas, tighten connections, and re-test.
  9. Restore Power: Once confident there are no leaks, restore electrical power to the appliance.
  10. Test Operation: Follow the appliance manufacturer's instructions to test the operation of the gas valve and burner.

5. Operating Instructions

The Goodman 0151F00000PS Gas Valve operates in conjunction with your appliance's control system. Its primary function is to regulate the flow of gas. Operation typically involves the following states:

Always refer to your specific appliance's user manual for detailed operating procedures, including startup and shutdown sequences.

6. Maintenance

The Goodman 0151F00000PS Gas Valve is designed for reliable operation and generally requires minimal maintenance. However, periodic inspection by a qualified technician is recommended as part of overall appliance maintenance.

7. Troubleshooting

If your appliance is not functioning correctly after gas valve installation, consider the following general troubleshooting steps. For complex issues, always consult a qualified HVAC technician.

8. Specifications

Detailed technical specifications for the Goodman 0151F00000PS Gas Valve:

BrandGoodman
Model Number0151F00000PS
Item Dimensions (L x W x H)13 x 13 x 10 inches
Inlet Connection Size4.8 Inches
Inlet Connection TypeFlare
Outlet Connection TypeFlare
Number of Ports2
Outlet Connection Size4.8 Inches
Specification MetANSI, ASME, ASTM
Item Weight3 pounds
Country of OriginUnited States

9. Warranty and Support

For warranty information regarding the Goodman 0151F00000PS Gas Valve, please refer to the documentation provided with your original appliance or contact Goodman directly. Warranty terms typically cover manufacturing defects and may vary.

For technical support or assistance with installation and troubleshooting, it is highly recommended to contact a qualified HVAC professional or the Goodman customer service department.

Goodman Contact Information: Please visit the official Goodman website for the most current contact details and support resources.

Related Documents - 0151F00000PS

Preview Goodman CVC9/95 & MVC95 Two-Stage Gas Furnace Installation Instructions
This document provides comprehensive installation instructions for Goodman and Amana CVC9/95 and MVC95 series two-stage gas furnaces. It details safety precautions, installation procedures, venting requirements, electrical connections, startup, and troubleshooting for professional installers.
Preview Goodman GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace Specifications
Detailed specifications, features, dimensions, airflow data, wiring diagrams, and accessories for the Goodman GMSS92 and GCSS92 single-stage multi-speed gas furnaces.
Preview Goodman MEC96/CEC96 Two-Stage Gas Furnace Installation Manual
Comprehensive installation, safety, and operation manual for Goodman and Amana MEC96/CEC96 series two-stage gas furnaces. Covers setup, troubleshooting, and maintenance for residential and commercial HVAC systems.
Preview Goodman (D, M)VC8 Gas Furnace Installation Instructions
Comprehensive installation instructions for the Goodman (D, M)VC8 Series Gas Furnace, covering safety, product application, location requirements, electrical connections, gas supply, startup procedures, and maintenance.
Preview Goodman GMES96/GCES96 ECM Gas Furnace Technical Specifications and Data
Comprehensive technical specifications, nomenclature, dimensions, airflow data, wiring diagrams, and available accessories for the Goodman GMES96 and GCES96 single-stage, multi-speed ECM gas furnaces, designed for high efficiency and reliable performance.
Preview Goodman/Amana M9S96/C9S96 & M9S92 Gas Furnace Installation Instructions
Comprehensive installation instructions for Goodman and Amana single-stage gas furnaces, models M9S96, C9S96, and M9S92. Covers safety, installation procedures, operation, and maintenance for Type FSP CATEGORY IV furnaces.