Hampton Bay CHQ7081T

Hampton Bay CHQ7081T Fan Remote Instruction Manual

Model: CHQ7081T

Introduction

This manual provides detailed instructions for the setup, operation, and maintenance of your Hampton Bay CHQ7081T fan remote control. This remote is designed to operate Hampton Bay ceiling fans, offering control over fan speeds, light functions, and fan direction. Please read this manual thoroughly before use to ensure proper functionality and to prevent damage.

Setup

1. Battery Installation

The Hampton Bay CHQ7081T remote requires one 9V battery (not included). Follow these steps to install the battery:

  1. Locate the battery compartment cover on the back of the remote control.
  2. Slide the cover downwards or press the tab and lift to remove it.
  3. Insert a new 9V battery, ensuring the positive (+) and negative (-) terminals align correctly with the markings inside the compartment.
  4. Replace the battery compartment cover, sliding it back into place until it clicks securely.

2. Dip Switch Configuration

For the remote control to communicate with your ceiling fan receiver, the dip switches on the remote must match the settings on the receiver. The CHQ7081T remote features 4 dip switches located within the battery compartment.

Hampton Bay CHQ7081T remote control with battery compartment open, showing 4 blue dip switches and a 9V battery connector.

Image: Hampton Bay CHQ7081T remote control with the battery compartment open, revealing the 4 dip switches and the 9V battery connector. The dip switches are small blue levers labeled 1-4.

  1. With the battery compartment open, identify the set of 4 small switches.
  2. Locate the dip switches on your ceiling fan's receiver unit (typically found in the fan's canopy or housing).
  3. Carefully adjust the switches on your CHQ7081T remote to exactly match the ON/OFF positions of the switches on your fan's receiver.
  4. Once matched, re-install the 9V battery and close the battery compartment.

Note: Incorrect dip switch settings will prevent the remote from controlling the fan.

Operating Instructions

The CHQ7081T remote provides intuitive control over your ceiling fan and its integrated lighting. The remote features dedicated buttons for various functions:

Hampton Bay CHQ7081T fan remote control showing buttons for fan speed, light control, and reverse function.

Image: Front view of the Hampton Bay CHQ7081T fan remote control, displaying buttons for fan speed (High, Med, Low, Off), light control (Up Light, Down Light), and fan direction (Reverse).

  • Fan Speed Buttons (High, Med, Low, Off): Press these buttons to adjust the fan speed or turn the fan off.
  • Light Buttons (Up Light, Down Light): Press once to turn the corresponding light on or off.
  • Dimming Function: To dim the lights, press and hold the respective Up Light or Down Light button. Release the button when the desired brightness level is reached.
  • Reverse Button (REV): Press this button to change the direction of the fan blades. This function is typically used to circulate air differently in summer (downward airflow) and winter (upward airflow).

Maintenance

Battery Replacement

When the remote's range decreases or buttons become unresponsive, it is likely time to replace the 9V battery. Follow the battery installation steps outlined in the Setup section.

Cleaning

To clean the remote control, use a soft, dry cloth. Do not use abrasive cleaners, solvents, or wet cloths, as these can damage the remote's surface or internal components.

Troubleshooting

If you experience issues with your Hampton Bay CHQ7081T remote, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Remote does not operate the fan/lights.Dead or low battery. Incorrect dip switch settings. No power to fan receiver.Replace 9V battery. Verify dip switch settings match the receiver. Check circuit breaker and wall switch for power to the fan.
Lights do not turn on/off or dim.Incorrect light button usage. Loose wiring in fan. Burnt-out light bulb.Press light button once for on/off, hold for dimming. Check fan wiring connections. Replace light bulb.
Fan does not change speed or direction.Incorrect dip switch settings. Fan motor issue.Ensure dip switch settings match the receiver. If problem persists, consult a qualified electrician or fan technician.
Remote signal range is reduced.Low battery. Interference.Replace 9V battery. Ensure no large metal objects or other radio frequency devices are blocking the signal path.

Specifications

  • Brand: Hampton Bay
  • Model Number: CHQ7081T (also known as UC7080T)
  • Connectivity Technology: Radio Frequency
  • Number of Buttons: 4 (Fan High, Med, Low, Off; Light Up, Light Down; Reverse)
  • Battery Type: 1 x 9V Alkaline battery (not included)
  • Compatible Devices: Ceiling Fans with CHQ7081T/UC7080T receiver
  • Special Feature: Ergonomic design

Warranty

No specific warranty information is provided for this product in the available documentation. Please refer to the original product packaging or contact the retailer for warranty details, if applicable.

Support

For further assistance or inquiries regarding your Hampton Bay CHQ7081T fan remote, please contact the manufacturer or your product retailer. Ensure you have your model number (CHQ7081T) available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.