1. Introduction
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Einhell BT-AC 230/24 Compressor. Please read this manual thoroughly before using the product and keep it for future reference.
2. Safety Instructions
Always adhere to general safety regulations when operating electrical equipment. Failure to follow these instructions may result in electric shock, fire, and/or serious injury.
- Ensure the compressor is placed on a stable, level surface.
- Do not operate the compressor in damp or wet conditions.
- Always wear appropriate personal protective equipment, including eye and ear protection.
- Before any maintenance or adjustment, disconnect the compressor from the power supply and ensure all pressure is released.
- Do not direct compressed air at people or animals.
- Regularly check hoses and connections for damage or leaks.
3. Product Features
The Einhell BT-AC 230/24 Compressor is designed for various compressed air applications. Key features include:
- Integrated handle for easy transport.
- Pressure regulator for precise control of output pressure.
- Safety valve to prevent over-pressurization.
- Air filter for clean air intake.
- Oil level control for proper lubrication maintenance.
- Large wheels for convenient mobility.
- Drain cock for condensate removal from the tank.
- Quick coupling for easy attachment of air tools.
- Non-return valve.
- Oil-lubricated pump for enhanced durability.
- 10-year guarantee against tank rust.

Figure 1: Overview of the Einhell BT-AC 230/24 Compressor, showing its blue tank, black motor housing, and transport handle.

Figure 2: Close-up view of the compressor's pressure gauges and the adjustable pressure regulator, indicating variable pressure from 0-8 bar.
4. Setup
Before first use, some assembly and preparation are required:
- Attach Wheels: Securely fasten the wheels to the compressor base using the provided hardware. This enhances mobility.
- Install Air Filter: Screw the air filter into its designated port on the compressor pump. This protects the pump from dust and debris.
- Check Oil Level: Verify the oil level using the oil level control (sight glass or dipstick). If necessary, add appropriate compressor oil to the recommended level. The pump is oil-lubricated.
- Positioning: Place the compressor on a firm, level surface in a well-ventilated area. Ensure adequate space around the unit for air circulation.
- Electrical Connection: Connect the compressor to a grounded 230 V ~ 50 Hz power outlet. Ensure the power supply matches the compressor's requirements.
5. Operating Instructions
Follow these steps for safe and effective operation:
- Initial Start-up:
- Ensure the drain cock is closed.
- Turn on the compressor. The motor will start, and the tank will begin to fill with air.
- Allow the compressor to reach its maximum operating pressure (max. 8 bar) and shut off automatically. This confirms proper function of the pressure switch.
- Adjusting Output Pressure: Use the pressure regulator knob to set the desired working pressure for your air tool. Monitor the output pressure gauge.
- Connecting Air Tools: Attach your air tool to the quick coupling.
- Operation: Begin using your air tool. The compressor will cycle on and off automatically to maintain tank pressure as needed.
- Shutting Down:
- Turn off the compressor.
- Disconnect the power supply.
- Slowly open the drain cock to release all air pressure from the tank. This is crucial for safety and to prevent tank rust.
6. Maintenance
Regular maintenance ensures the longevity and performance of your compressor:
- Daily:
- Drain condensate from the tank using the drain cock. This prevents rust and maintains tank capacity.
- Weekly/After 10-20 Operating Hours:
- Check oil level and top up if necessary. Use only recommended compressor oil.
- Inspect the air filter. Clean or replace if it appears dirty or clogged.
- Monthly/After 50 Operating Hours:
- Check all bolts and fittings for tightness.
- Inspect hoses and connections for wear, cracks, or leaks.
- Annually:
- Change the compressor oil.
- Have a qualified technician inspect the safety valve and pressure switch.
Warning: Always disconnect the power supply and release all pressure before performing any maintenance.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Compressor does not start. | No power supply; Thermal overload activated; Faulty switch. | Check power connection and circuit breaker; Allow motor to cool down; Contact service. |
| Compressor runs continuously or frequently. | Air leak in system; Drain cock open; Pressure switch malfunction. | Check all connections and hoses for leaks; Close drain cock; Contact service. |
| Low air pressure output. | Pressure regulator set too low; Air filter clogged; Air leak. | Adjust pressure regulator; Clean/replace air filter; Check for leaks. |
| Excessive noise or vibration. | Loose components; Insufficient oil; Worn parts. | Tighten all bolts; Check/add oil; Contact service. |
8. Specifications
| Specification | Value |
|---|---|
| Manufacturer | Einhell |
| Item Code | BT-AC 230/24 |
| Model Number | 4010350 |
| Product Dimensions | 27 x 59.5 x 60.5 cm |
| Tank Capacity | 24 L |
| Item Weight | 25 kg |
| Power Type | Corded Electric |
| Voltage | 230 V |
| Wattage | 1500 W |
| Motor Power | 1.5 kW (2 HP) S2 15 min |
| Air Flow Rate | 206 L/min |
| Speed | 2,850 rpm |
| Operating Pressure | Max. 8 bar |
| Number of Cylinders | 1 |
| Electrical Plug Type | C - 2 pin Europlug |
| Included Components | No additional components |
9. Warranty and Support
Einhell provides a 10-year guarantee against rust on the compressor tank. For warranty claims, technical support, or spare parts, please contact Einhell customer service or visit their official website. Keep your purchase receipt as proof of purchase.
For further assistance, refer to the official Einhell website or contact their authorized service centers.